3200 NXT

Engineering summary from PDF text extraction for 3200 NXT. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: 3200NXT Network Controller
  • Part No.: 42693 Rev A

Features

  • 2x16 character backlit LCD display
  • Networks up to four valves
  • Field-configurable for System Types 4, 5, 6, 7, and 9
  • Auxiliary inputs and outputs:
    • Remote signal start input
    • Remote lockout input
    • Programmable relay output/chemical pump output
  • Easy installation with plug-in wiring harnesses
  • Front panel diagnostics button for:
    • Flow rate
    • Peak flow rate
    • Totalizer
    • Hours between last two regenerations
    • Hours since last regeneration
    • Adjustable volume remaining
    • Valve position
    • Software version
  • Easy time of day adjustment (automatically copied to networked controllers)
  • Five configurable cycle steps
  • Remote signal start can be used simultaneously with time clock, meter immediate, or meter delayed regeneration triggers (allows monitoring of flow and volume information in RSS applications)

Programming Levels

  • User mode
  • Master programming
  • Diagnostics mode

The 3200NXT Network Controller links multiple commercial valves using off-the-shelf CAT3, CAT5, or better cables for various system types. It is configured for use with Fleck® 2750, 2850s, 2900s, 3150, and 3900 Control Valves and supports stager valves with butterfly or notched cams.

System Types

  • System 4 (Single Valve): Time Clock, Delayed, One Meter Immediate, One Meter Remote Signal Start, Optional Meter
  • System 5 (Interlock, 2-4 Valves): Immediate, All Meters, Remote Signal Start, Optional Meter
  • System 6 (Series, 2-4 Valves): Immediate, All Meters, Remote Signal Start, Optional Meter
  • System 7 (Alternating, 2 Valves): Immediate, One Meter, Remote Signal Start, Optional Meter
  • System 9 (Alternating, 2-4 Valves): Immediate, All Meters, Remote Signal Start, Optional Meter

Regenerant Flow

  • Downflow, Upflow Brine First, Upflow Brine Refill First

Generic Meter Guidelines

  • Open collector output.
  • Pulse rate generated must not exceed 100 pulses per second (100 Hz), or 6,000 pulses per minute.
  • Support for meter outputs in the range of 1-255 gallons (25.5 m³) for every 1-255 pulses (e.g., 35 gallons/100 pulses).
  • Meter must operate at 5 VDC.

Electrical Rating

  • Transformers: 24 VAC Pentair® Transformers
    • 115 VAC +/- 20% input, 24 VAC output
    • 230 VAC +/- 20% input, 24 VAC output

Humidity

  • 95% RH, Non-Condensing

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.