Datasheet summary

Fleck 3900

Engineering summary from PDF text extraction for Fleck 3900. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: 3900
  • Type: 3" Control Valve

Features

  • Fully adjustable, 5-cycle control delivers upflow backwash, downflow brining, slow rinse, rapid rinse, and downflow service.
  • Designed for single tank or multi-tank systems, alternating or interlocking.
  • Protective NEMA 3R enclosure is water-resistant, corrosion-resistant, and UV stable.
  • Choice of 7 or 12 day clock or meter initiated regeneration.

Operating Limits

  • Pressure:
    • Hydrostatic: 300 psi
    • Working: 20 - 125 psi
  • Temperature: 34° - 110° F

Flow Rates (50 psi Inlet) - Valve Alone

  • Continuous (15 psi drop): 250 GPM
  • Peak (25 psi drop): 325 GPM
  • Cv (flow at 1 psi drop): 65
  • Max. backwash (25 psi drop): 100 GPM

Regeneration

  • Cycles: 5
  • Type: Downflow/Upflow
  • Adjustable cycles: Yes
  • Time available:
    • Electromechanical: 164 minutes
    • 3200NXT/3214NXT/XT: 240 minutes per cycle

Meter Information

  • Meter accuracy: 7 - 300 GPM +/- 5%
  • Meter capacity range (gal.):
    • Standard: 3,750 - 63,750
    • Extended: 18,750 - 318,750
    • 3200NXT/3214NXT/XT: 9,900,000

Mechanical / Hydraulic

  • Valve material: Lead-free brass*
  • Inlet/Outlet: 3" NPT
  • Distributor pilot: 3" O.D.
  • Drain line: 2" NPTF
  • Injector brine system: 1"
  • Mounting base: Top: 6" - 8" threaded or flanged
  • Height from top of tank: 15"

Electrical

  • Rating: 24 v, 110 v, 200 v - 50 Hz, 60 Hz

Additional Information

  • Estimated shipping weight:
    • Time clock: 93 lbs.
    • Metered valve: 115 lbs.
  • *As defined in the U.S. EPA Safe Drinking Water Act; the product also meets California Proposition 65 Standards.
  • Tested and Certified by the WQA to NSF/ANSI Std. 61 Section 8 Material Safety Only and Annex "G".

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.