Fleck 3900
Engineering summary from PDF text extraction for Fleck 3900. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: 3900
- Type: 3" Control Valve
Features
- Fully adjustable, 5-cycle control delivers upflow backwash, downflow brining, slow rinse, rapid rinse, and downflow service.
- Designed for single tank or multi-tank systems, alternating or interlocking.
- Protective NEMA 3R enclosure is water-resistant, corrosion-resistant, and UV stable.
- Choice of 7 or 12 day clock or meter initiated regeneration.
Operating Limits
- Pressure:
- Hydrostatic: 300 psi
- Working: 20 - 125 psi
- Temperature: 34° - 110° F
Flow Rates (50 psi Inlet) - Valve Alone
- Continuous (15 psi drop): 250 GPM
- Peak (25 psi drop): 325 GPM
- Cv (flow at 1 psi drop): 65
- Max. backwash (25 psi drop): 100 GPM
Regeneration
- Cycles: 5
- Type: Downflow/Upflow
- Adjustable cycles: Yes
- Time available:
- Electromechanical: 164 minutes
- 3200NXT/3214NXT/XT: 240 minutes per cycle
Meter Information
- Meter accuracy: 7 - 300 GPM +/- 5%
- Meter capacity range (gal.):
- Standard: 3,750 - 63,750
- Extended: 18,750 - 318,750
- 3200NXT/3214NXT/XT: 9,900,000
Mechanical / Hydraulic
- Valve material: Lead-free brass*
- Inlet/Outlet: 3" NPT
- Distributor pilot: 3" O.D.
- Drain line: 2" NPTF
- Injector brine system: 1"
- Mounting base: Top: 6" - 8" threaded or flanged
- Height from top of tank: 15"
Electrical
- Rating: 24 v, 110 v, 200 v - 50 Hz, 60 Hz
Additional Information
- Estimated shipping weight:
- Time clock: 93 lbs.
- Metered valve: 115 lbs.
- *As defined in the U.S. EPA Safe Drinking Water Act; the product also meets California Proposition 65 Standards.
- Tested and Certified by the WQA to NSF/ANSI Std. 61 Section 8 Material Safety Only and Annex "G".