Back to Pentair Water Softeners
Pentair logo

Datasheet summary

Fleck 9500

Engineering summary from PDF text extraction for Fleck 9500. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: 9500
  • Type: 1.5" Twin Tank Control Valve

Features

  • Fully adjustable 5-cycle control (upflow backwash, downflow brining, slow rinse, rapid rinse, timed brine refill, downflow service)
  • Easily-adjustable, 5-cycle, downflow-brining control
  • Backwash capability for up to 24" diameter tanks
  • Lead-free brass valve body
  • Total flexibility in meter and timer setting
  • Satisfies operational needs from 3,125 to 53,125 gallons
  • Uses conditioned water for regeneration
  • 100% capacity of tank in service before switching to the second tank
  • Regenerates immediately when needed for continuous soft water
  • Regenerates with soft water for optimum operating efficiency and minimum maintenance

Options

  • Bypass valve (Fiber-reinforced polymer or lead-free brass)
  • Hot water capability (150°F max., 1" meter only)
  • Auxiliary switches
  • 3200 mechanical timer, SXT or XT electronic timer
  • Cover with window for electronic timers

Valve Specifications

  • Valve material: Lead-free brass
  • Inlet/Outlet: 1-1/2" NPTF
  • Cycles: 5
  • Regeneration type: Downflow/Upflow or Downflow only
  • Adjustable cycles: Yes

Flow Rates (50 psi Inlet) - Valve Alone

  • Continuous (15 psi drop): 38 GPM
  • Peak (25 psi drop): 49 GPM
  • Cv (flow at 1 psi drop): 9.8
  • Max. backwash (25 psi drop): 16 GPM

Regeneration Time

  • Electromechanical: 82 or 164 minutes
  • SXT: 0 - 199 minutes per cycle
  • XT: 240 minutes per cycle

Meter Information

  • Flow range: 1.5 - 75 GPM
  • Meter capacity range (gal.):
    • Standard: 625 - 10,625
    • Extended: 3,125 - 53,125
    • SXT: 1 - 999,900
    • XT: 1,000 - 9,900,000

Mechanical / Hydraulic

  • Distributor pilot: 1.5" pipe I.D.
  • Drain line: 1" NPTM
  • Injector brine system: 1/2" & 3/8"
  • Mounting base: 4" - 8 UN
  • Height from top of tank: 7-1/4"

Typical Applications

  • Water softener tanks: 10" - 24" diameter

Operating Limits

  • Pressure:
    • Hydrostatic: 300 psi
    • Working: 25 - 125 psi
  • Temperature: 34°F - 110°F

Electrical

  • Rating: 24 V, 110 V, 200 V - 50 Hz, 60 Hz
  • Max. VA: 8.9

Additional Information

  • Estimated shipping weight (metered value): 48 lbs.
  • Certifications: Tested and certified by the WQA to NSF/ANSI Std. 61 Section 8 (Material Safety Only) and Annex "G".
  • Materials meet U.S. EPA Safe Drinking Water Act and California Proposition 65 Standards.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.