Back to Pentair Water Softeners
Pentair logo

Datasheet summary

Composite Vessels

Engineering summary from PDF text extraction for Composite Vessels. Verify every value with the OEM datasheet.

Summary

Product Identification

These are composite fiberglass vessels for commercial and industrial water treatment and storage. They are designed to not rust and require little or no maintenance.

Product Features

  • 100% composite fiberglass construction
  • Outstanding performance and durability in harsh chemical environments
  • Absolutely will not rust
  • Requires little or no maintenance
  • Capacities up to 2500 gallons
  • Factory-backed five-year warranty

Materials of Construction

  • Polyethylene inner shell (PVDF available)

Operating Parameters

  • Maximum operating pressure: 150 psi
  • Maximum operating temperature:
    • 150°F (flanged)
    • 120°F (threaded)

Design Parameters

Pentair Design Parameters

  • Safety factor: 4:1
  • Minimum burst at 600 psi
  • Tested to 250,000 cycles without leakage

NSF Design Parameters

  • Safety factor: 4:1
  • Minimum burst at 600 psi
  • Tested to 100,000 cycles without leakage

ASME Design Parameters

  • Safety factor: 5:1
  • Minimum burst at 750 psi
  • Tested to 33,000 cycles without leakage

Additional ASME Parameters (Side Entry)

  • Safety factor: 6:1
  • Minimum burst at 900 psi
  • Tested to 100,000 cycles without leakage

Specifications Table

See the official PDF for exact tabulated values for various part numbers, descriptions, dimensions, capacities, and connection types.

Dome Volume and Straight Wall Gallon per Inch

Nominal Diameter (inches)Gallons* (One Dome)Gallon / Inch (Approx.)A (Sq. Feet)
121.00.50.7
131.40.50.9
141.70.61.1
162.70.81.3
183.71.01.8
216.21.42.4
249.31.93.0
30182.94.6
36334.26.7
42525.79.0
48747.512.0
6316813.020.0

* Cubic Ft. = 0.1337 x Gallons

Installation Notes

  • Flexible connections must be installed between hard piping and tank openings. Failure to install flex connections properly with the vessel will void the warranty.
  • Pressure vessels are rated for an internal negative pressure of 5" Hg (17 Pa) vacuum below atmospheric. If negative pressure could exceed 5" Hg (17 Pa), an adequate vacuum breaker must be installed.
  • Bolt base to floor.
  • Calculate height for valve and base combined.

Color Options

  • AL - Almond
  • BL - Blue
  • BK - Black
  • GR - Gray
  • NA - Natural

Top and Bottom Opening Threads

SizeNumber of Full ThreadsComposite
2.5"- 8" NPSM3 min6
4"- 8" UN3 min7
4.5"- 8" Buttress3 min7

Top and Bottom Opening Flanges/Manway

SizeLI.D.B.C.O.D.Bolt Dia.Number of HolesWeight (lbs.)
6" SNA3.6"5.9"8.5"9.4"0.31"125.8
10" ANSI3.7"10.0"14.3"16.0"0.88"1217.8
16" Manway SNA4.3"16.0"20.4"21.3"0.50"2434.0

Manway Cover

MaterialPressure RatingTapping
CPVC100 psiAs requested
VE150 psiAs shown only

Side Flange

SizeLI.D.B.C.O.D.Bolt Dia.Number of HolesWeight (lbs.)
4" ANSI4.1"4.0"7.5"9.0"0.63"86.4

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror