Datasheet summary
SFE-EV PRO controller Duplex Std
Engineering summary from PDF text extraction for SFE-EV PRO controller Duplex Std. Verify every value with the OEM datasheet.
Summary
Product Identification
SIATA offers a range of water treatment valves and controllers, including the SFE/SFE-EV, AT-PLUS, AC, AT, AC-PLUS, AC-MULTIPLEX, and AI series controllers, compatible with various valve models.
Valves and Controllers Correspondence
The document provides a correspondence table detailing valve models and their applicable controllers for different water treatment applications:
- Residential:
- Simplex softening (time clock/metered): V132A/V1191, V132T with SFE/SFE-EV
- Duplex alternating softening: V132E/V2191 with SFE/SFE-EV
- Simplex filter: V132F with SFE
- Commercial:
- Simplex softening (time clock/metered): V132A/V230A/V240A, V132T/V230T/V240T with SFE/SFE-EV and AT-PLUS
- Simplex filter: V230F/V240F/V250F/V260F with SFE
- Duplex alternating softening: V132E/V230E/V240A with AC, AT-PLUS/AC-PLUS
- Duplex parallel softening metered: V132E-T/V230E-T/V240A-T with AC-PLUS
- Triplex softening parallel and alternating: V132E-T/V230E-T/V240A-T with AC-MULTIPLEX
- Simplex dealkanization: V132D/V230D/V240D with SFE, AT-PLUS
- Duplex dealkanization: V132D/V230D/V240D with AC, AT-PLUS/AC-PLUS
- Simplex deionization: V132D/V230D/V240D with AI, AI-PLUS
- Duplex deionization: V132D/V230D/V240D with AI-PLUS DUPLEX
- Commercial/Light Industrial:
- Simplex softening metered & time clock: V250A/V260A with SFE/SFE-EV2, AT-PLUS
- Simplex filter: V350F/V351F with SFE3, AT-PLUS
- Duplex alternating softening: V250A/V260A with AC, AT-PLUS/AC-PLUS
- Duplex parallel softening: V250A/V260A with AT, AC-PLUS
- Triplex softening: V250A/V260A with AC-MULTIPLEX
- Simplex dealkanization: V250D/V260D with SFE, AT-PLUS
- Duplex dealkanization: V250D/V260D with AC, AT-PLUS/AC-PLUS
- Simplex deionization: V250D/V260D with AI, AI-PLUS
- Duplex deionization: V250D/V260D with AI-PLUS DUPLEX
- Industrial:
- Simplex softening metered & time clock: V360SMA with SFE, AT-PLUS
- Simplex filter: V363 with SFE3, AT-PLUS
- Duplex alternating softening: V360SMA with AC, AT-PLUS/AC-PLUS
- Duplex parallel softening: V360SMA with AT, AC-PLUS
- Triplex softening: V360SMA with AC-MULTIPLEX
- Simplex dealkanization: V360SMD with SFE, AT-PLUS
- Duplex dealkanization: V360SMD with AC, AT-PLUS/AC-PLUS
- Simplex deionization: V360SMD with AI, AI-PLUS
- Duplex deionization: V360SMD with AI-PLUS DUPLEX
Accessories
Pentair has developed specific accessories including:
- Turbine meters
- Brine valves
- Patented by-pass valves
- Metal adapters
- Flow regulators
- Check valves
- Chlorine producers
- Distributors
Valve Specifications
| Valve Model | Material | Inlet/Outlet | Service Flow Rate (m³/h / gpm) | Backwash Flow Rate (m³/h / gpm) | Valve Mounting | Filter Option | Duplex |
|---|---|---|---|---|---|---|---|
| V119/219 | ABS | 3/4” | 2 / 9 | No | Top mount | No | |
| V132 | ABS | 2” | 7 / 30 | 3 / 13 | Top mount | • | • |
| V230 | ABS | 2” | 8.5 / 37.4 | 4 / 17.6 | Top mount | • | • |
| V240 | ABS | 2” | 8.5 / 37.4 | 4 / 17.6 | Side mount | • | • |
| V250 | ABS | 2” 1/4 | 21 / 92.5 | 12 / 52.8 | Top mount | • | • |
| V260 | ABS | 2” 1/4 | 21 / 92.5 | 12 / 52.8 | Side mount | • | • |
| V360 | ABS | 3” | 32 / 141 | 15 / 66 | Side mount | • | • |
| V350 | ABS | 2” 1/4 | 23 / 101 | 31 / 137 | Side mount | • | • |
| V351 | ABS | 2” 1/4 | 23 / 101 | 31 / 137 | Top mount | • | • |
| V363 | ABS | 2” 3/4 | 36 / 159 | 48 / 211 | Side mount | • | • |
Note: Upflow regeneration is indicated with '•'. Specific notes for valves V119/219 and SFE-EV are provided.
Controller Applications and Technical Specifications
| Controller Series | Applications | Technical Specifications |
|---|---|---|
| SFE / SFE-EV | Softening, Filtration | Time clock, Adjustable cycle time, Holidays mode, Remote regeneration start, Inhibit signal in/out, Relay on board |
| SFE-EV2 | Softening, Filtration | Time clock, Adjustable cycle time, Holidays mode, Remote regeneration start, Inhibit signal in/out, Relay on board |
| SFE3 | Filter | Time clock, Adjustable cycle time, Holidays mode, Remote regeneration start, Inhibit signal in/out, Relay on board |
| AT-PLUS | Softening, Filtration, Dealkanization, Iron removal | Volumetric, Immediate/Delayed, Adjustable cycle time, Holidays mode, Remote regeneration start, Inhibit signal in/out, Relay on board |
| AC / AC-PLUS | Softening, Filtration, Dealkanization, Iron removal | Immediate/Delayed, Adjustable cycle time, Chlorine cell management, Duplex system control (Alternating/Parallel), Holidays mode, Remote regeneration start, Inhibit signal in/out, Relay on board |
| AT / AC-PLUS | Duplex parallel softening | Immediate, Adjustable cycle time, Duplex system control (Parallel), Remote regeneration start, Inhibit signal in/out, Relay on board |
| AC-MULTIPLEX | Triplex softening parallel and alternating | Immediate, Adjustable cycle time, Duplex system control (Alternating/Parallel), Remote regeneration start, Inhibit signal in/out, Relay on board |
| AI / AI-PLUS | Deionization | Immediate, Adjustable cycle time, Holidays mode, Remote regeneration start, Inhibit signal in/out, Relay on board |
| AI-PLUS DUPLEX | Duplex deionization | Immediate, Adjustable cycle time, Holidays mode, Remote regeneration start, Inhibit signal in/out, Relay on board |
| Aquacubic | Softening, Filtration | Time clock, Adjustable cycle time, Calendar override, Relay on board |
| Aquacubic Plus | Softening, Filtration, Dealkanization, Iron removal | Volumetric, Immediate/Delayed, Adjustable cycle time, Calendar override, Relay on board |
| Aquatimer | Softening, Filtration | Time clock, Adjustable cycle time, Calendar override, Relay on board |
| Aquatimer Plus | Softening, Filtration, Dealkanization, Iron removal | Volumetric, Immediate/Delayed, Adjustable cycle time, Calendar override, Relay on board |
| Aquaionic | Deionization | Immediate, Adjustable cycle time, Calendar override, Relay on board |
| Aquaionic Plus | Deionization | Immediate, Adjustable cycle time, Calendar override, Relay on board |
| Aquaionic Plus Duplex | Duplex deionization | Immediate, Adjustable cycle time, Calendar override, Relay on board |
| RO Easy/RO EV | Reverse osmosis | Immediate, Adjustable cycle time, Calendar override, Relay on board |
Note: Some controllers offer optional features like microswitch, chlorine cell management, duplex system control, holidays mode, remote regeneration start, inhibit signal in/out, and variable brining.
Quality and Certifications
All SIATA products are certified by major EU certificates including CE, 206 / 95 / EC low voltage, 2004 / 108 / EC electromagnetic compatibility, ACS and DM174. The Pisa plant is ISO 9001:2008 certified.
Deionization Valves
SIATA offers valves specifically designed for DI applications, constructed from glass fibre reinforced ABS, which resist regenerants such as NaOH, HCl, and H₂SO₄.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.