Datasheet summary
V132A Softener Body
Engineering summary from PDF text extraction for V132A Softener Body. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: SIATA Residential Valve
- Model: V132
- Series: Water Purification Valves - SIATA
Technical Characteristics
- Flow rate: up to 7 m³/h
- Installation: Quick connect clips for easy installation and maintenance
- Compatibility: Compatible with the entire SIATA controller range
- Typical Applications:
- Softening
- Demineralisation
- Filtration
- Mixing Device: Included (for residential softeners up to 800 L/h flow rate, for pressure vessels up to 10x35 inches diameter)
- Backwash Flow Control: Included (for filter and demineralisation installations)
- Driver Replica: Available for special applications (e.g., to drive an external brine valve or close valve outlet)
Flow Rate
- Continuous (Δp = 1 bar): 7.0 m³/h (Cv* = 7.32 gpm)
- Maximum Backwash (Δp = 1.8 bar): 3.0 m³/h
- Regeneration Cycles: Adjustable depending on fitted controller
Valve Specifications
- Material: Glassfiber reinforced ABS
- Hydrostatic Pressure: 22 bar
- Working Pressure: 1.5 - 6 bar
- Working Temperature: 5 - 40°C
Dimensions
- Inlet/Outlet: Male 2 inches BSP or various QC** fittings
- Distributor Pilot: 32 mm O.D.
- Drain Line: 20 mm - QC**
- Brine Line: 3/8 inch
- Mounting Base (Top): 2.5 inches 8 NPSM
- Height (from top of tank): 129 mm ± 2
Tank Size Application (Recommended)
- Water Softener: 8 - 16 inches (max 200 L of resin)
- Filter: 8 - 16 inches (according to filter media specs)
- Demineralisation: 8 - 16 inches (max 200 L of resin)
Meter Accuracy
- Accuracy Range 3/4 inch (± 5%): 12 - 150 Lpm
- Accuracy Range 1 1/2 inch (± 5%): 36 - 200 Lpm
Regeneration Cycles
- Softener & Demineralisation:
- Backwash (Upflow)
- Brine & slow rinse (Down flow)
- Rapid rinse (Down flow)
- Filter:
- Backwash (Upflow)
- Rapid rinse (Down flow)
Options
- Mixing: Yes
- Backwash Flow Control: Yes
- Driver Replica: Yes
- *Cv: Flow rate of valve alone in gpm at 0.07 bar pressure drop.
- ** QC: Quick connect.
Disclaimer This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.