Datasheet summary
V240A Softener valve body
Engineering summary from PDF text extraction for V240A Softener valve body. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: SIATA V240
- Type: Water Purification Valve
- Application: Softener, demineralisation, dealkalisation, and filtration systems.
- Mounting: Side mounted valve
Operating limits
- Working Pressure: 1.5 to 6 bar
- Hydrostatic Pressure: 22 bar
- Working Temperature: 5° to 40°C
Feed water
- Flow Rate (Continuous, ∆p = 1 bar): 8.5 m³/h
- Flow Rate (Peak, ∆p = 1.9 bar): 11.7 m³/h
- Maximum Backwash Flow Rate (∆p = 1.9 bar): 4 m³/h
- Maximum Rapid Rinse Flow Rate (∆p = 1.9 bar): 5.5 m³/h
- Cv (Flow rate of valve alone at 0.07 bar pressure drop): 9.88
Tank size application (Recommended)
- Water Softener: 14’’ - 24’’ (max 300 L of resin)
- Filter: 14‘‘ - 21’’ (according to filter media specs)
- Demineralisation: 14‘‘ - 21’’ (max 200 L of resin)
Electrical
- Not specified in the extract.
Mechanical / hydraulic
- Inlet / Outlet Ports: 2’’ BSP
- Drain Line Connector: Threaded
- Material: ABS + 17% glass fiber
- Color: Blue / black
- Regeneration Cycles: Adjustable depending on controller fitted. Can support upflow and downflow regeneration. Duplex systems are supported. External DLFC 1” 1/4 is available.
- Inlet/Outlet Connection Options:
- 2265-A/05: ¾” BSP female
- 2265-B/05: 1” BSP female
- 2265-C/05: 1 ¼” BSP female
- 2265-D/05: 32 mm to glue
- 2265-H/05: 1 ½” male and 1” female
- 2265-I/05: 2” male and 1 ¼” female
- 2265-K/05: 1 ½” BSP female
- Optional Quick Fittings:
- 494-B/05: 1 ¼” BSP female (PVC-PVC)
- 494-C/05: 40 mm to glue (PVC-PVC)
- 494-F/05: 1 ¼” BSP female (Brass-brass)
- 494-S/05: 1 ¼” NTP (PVC-PVC)
- 494-T/05: 1 ¼” NTP (PVC-PVC)
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.