V360A Softener valve body

Engineering summary from PDF text extraction for V360A Softener valve body. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Line: Siata Control Valves
  • Model: V360 - Industrial Valve
  • Type: Water Purification Valve

Technical Specifications

  • Side mounted valve
  • Up to 32 m³/h flow rate
  • Quick pilot connections
  • Suitable for industrial softening, demineralisation, dealkalisation applications, as well as filtration systems
  • High flow rate pistons for improved performances
  • Compatible with most of the SIATA controller range

Technical Characteristics

  • Material: Glassfiber reinforced ABS
  • Color: Blue or black
  • Hydrostatic pressure: 22 bar
  • Working pressure: 2 to 6 bar
  • Working temperature: 5 to 40°C

Valve Connections

  • Inlet / outlet: Up to 3” flanged – threaded or to be glued
  • Drain line connector: 40 mm ISO – molded in outlet body
  • Mounting base / Tank connection: Side mount / flanged
  • Adjustable cycles: Depending on controller fitted

Flow Rate

  • Continuous (∆p = 1 bar): 32 m³/h
  • Peak (∆p = 1.9 bar): 42 m³/h
  • Cv: 36.8 (Flow rate of valve alone in GPM at 0.07 bar pressure drop)
  • Maximum backwash (∆p = 1.9 bar): 15 m³/h
  • Maximum rapid rinse (∆p = 1.9 bar): 18 m³/h

Inlet/Outlet Connection Options

  • 364-A: 1 ½” BSP
  • 364-B: 2” BSP
  • 364-C: 2 ½” BSP
  • 364-D: 3” BSP
  • 364R-Q01: D90 GLUED
  • 364-E01: ISO 50 GLUED
  • 364-F01: ISO 63 GLUED
  • 364-G01: ISO 75 GLUED
  • 364-N01: Ø 60.4 GLUED
  • 364-P01: 3” NPT GLUED
  • 364R-D_3''_BSP

Options

  • Up Flow regeneration: Yes
  • Duplex systems: Yes
  • External DLFC 1” ¼: Yes

Tank Size Application (Recommended)

  • Water softener: 24” - 48” (max 1200 l of resin)
  • Filter: 24” - 48” (according to filter media specs)
  • Demineralisation: 24” – 48” (max 1200 l of resin)

Regeneration Cycles

  • Softener & Demineralisation:
      1. Backwash (Down flow)
      1. Brine & slow rinse (Down flow)
      1. Rapid rinse (Down Flow)
  • Filter:
      1. Backwash (Up flow)
      1. Rapid rinse (Down Flow) (Note: Depending on the controller type, brine draw and slow rinse time must be set to 0.)

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.