LX-HI

Engineering summary from PDF text extraction for LX-HI. Verify every value with the OEM datasheet.

Summary

Product identification

IONPURE® LX-HI Instant Hot Water Sanitizable Continuous Electrodeionization (CEDI) Modules are designed for pharmaceutical, biotechnology, and other applications requiring chemical-free, instant hot water sanitization. These modules produce high-purity water without regeneration downtime.

Key features include:

  • Hot water sanitizable at 185°F/85°C ± 5°C
  • Continuous operation up to 140°F (60°C)
  • US Patented technology for instant hot water capability – no ramp up/down required
  • Higher sanitization pressures: 30 psi/2.0 bar
  • Double O-ring seal guarantees leak-free operation
  • Proven performance after 150+ sanitizations
  • Concentrate recirculation and brine injection not required
  • Wetted materials of construction comply with FDA requirements

Operating limits

  • Continuous Operating Temperature: Up to 140°F (60°C)
  • Maximum Feed Temperature: 113°F (45°C)
  • Maximum Ambient Room Temperature: 113°F (45°C)
  • Sanitization Temperature: 185°F (85°C) at 30 psi (2.0 bar)
  • Maximum Feed Pressure: 100 psi (7 bar)

Feed water

  • Feed Water Conductivity Equivalent, including CO₂ and Silica: < 40 μS/cm
  • Temperature: 40 - 140° F (5 - 60° C)
  • Inlet Pressure: 20 - 100 psi (1.4 - 7 bar)
  • Maximum Free Chlorine (as Cl): < 0.02 ppm
  • Iron (as Fe): < 0.01 ppm
  • Manganese (as Mn): < 0.01 ppm
  • Sulfide (S²⁻): < 0.01 ppm
  • pH: 4 – 11
  • Total Hardness (as CaCO₃): < 1.0 ppm
  • Dissolved Organics (TOC as C): < 0.5 ppm
  • Silica (SiO₂): < 1.0 ppm

Product water

  • Typical Recovery: 90 – 95%
  • Product Conductivity: < 0.1 μS/cm
  • Silica (SiO₂) Removal: 90 – 99%, depending on feed water

Electrical

  • DC Voltage*: 0 – 600
  • DC Amperage: 0 - 10

*Voltage required depends on module size.

Mechanical / hydraulic

Product Flow Rates

Item NumberProduct Flow min. gpm (m³/hr)Product Flow nominal gpm (m³/hr)Product Flow max. gpm (m³/hr)
IP-LXM04HI-31.0 (0.22)2.0 (0.44)3.0 (0.67)
IP-LXM10HI-32.5 (0.55)5.0 (1.1)7.5 (1.65)
IP-LXM18HI-34.5 (1.1)9.0 (2.0)13.5 (3.1)
IP-LXM24HI-36.3 (1.4)12.5 (2.8)18.8 (4.2)
IP-LXM30HI-37.5 (1.65)15.0 (3.3)22.5 (5.11)
IP-LXM45HI-311.3 (2.55)22.5 (5.1)33.8 (7.67)

Weights

Item NumberShipping Weight lbs (kg)Operating Weight lbs (kg)
IP-LXM04HI-3150 (68)110 (50)
IP-LXM10HI-3200 (91)150 (68)
IP-LXM18HI-3220 (100)170 (77)
IP-LXM24HI-3250 (113)200 (91)
IP-LXM30HI-3270 (123)220 (100)
IP-LXM45HI-3320 (145)270 (122.5)

Dimensions

Item NumberL ± .25” (6.4 mm)M ± .13” (3.2 mm)
IP-LXM04HI-311.81“ (300.0 mm)7.47“ (189.7 mm)
IP-LXM10HI-315.29“ (388.6 mm)10.96“ (278.5 mm)
IP-LXM18HI-319.91“ (505.7 mm)15.62“ (396.7 mm)
IP-LXM24HI-323.38“ (593.9 mm)19.12“ (485.6 mm)
IP-LXM30HI-327.42“ (696.5 mm)22.61“ (574.2 mm)
IP-LXM45HI-335.72“ (907.3 mm)31.35” (796.3 mm)
  • Pressure Drop Range at Nominal Flow: 20 - 30 psi (1.4 - 2.1 bar)

Quality Assurance

  • CE marked.
  • Each module is factory tested to meet strict industry standards.
  • Manufactured in an ISO 9001 and ISO 14000 quality and environmental management system.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data and complete specifications, the official OEM PDF revision used on the project must be consulted.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.