Back to Evoqua / Ionpure, EDI modules
IonPure logo

Datasheet summary

LX-MK

Engineering summary from PDF text extraction for LX-MK. Verify every value with the OEM datasheet.

Summary

Product identification

  • Manufacturer: Evoqua Water Technologies
  • Model: LX-MK
  • Country of Origin: United States of America
  • Endplate Material: Machined aluminum
  • Cell Spacer Material: PVC

The IONPURE LX-MK module is a continuous electrodeionization (CEDI) system designed for final water polishing. It utilizes ion exchange resins that are continuously regenerated by an imposed electric current, eliminating the need for chemical regeneration. This technology has been applied in pharmaceutical, power, microelectronics, and food/beverage industries since 1987.

CEDI Process Overview

The CEDI process removes ionized or ionizable substances from water using ion exchange membranes, electrically active media (ion exchange resin), and a DC electric potential. It involves three coupled processes:

  1. Feed: RO permeate is fed through alternating dilute and concentrate compartments. A fraction of the flow is diverted to concentrate and electrode compartments. Ion exchange resin accepts ions from the feed water.
  2. Removal: The ion exchange resin serves as a bridge for cations and anions to travel. A DC electrical field causes ions to migrate toward ion selective membranes and into adjacent concentrate compartments, where they are carried away by the concentrate flow.
  3. Regeneration: Electric potential causes some water to split into hydrogen and hydroxyl ions, continuously regenerating the ion exchange resins in-situ without chemical reagents.

Benefits of Electrodeionization

  • Continuous operation, no downtime for regenerations.
  • Truly chemical-free process, no brine injection required.
  • One pass operation, no need for concentrate recirculation.
  • Guaranteed leak free.
  • Proven technology.

Operating limits

  • Maximum Feed Temperature: 113°F (45°C)
  • Minimum Feed Temperature: 41°F (5°C)
  • Maximum Feed Pressure: 100 PSIG (7 bar) (@113°F (45°C) maximum temperature)

Pressure Drop

  • @ minimum flow rate: 10-15 psi (0.69-1.03 bar)
  • @ nominal flow rate: 25-35 psi (1.72-2.41 bar)
  • @ maximum flow rate: 40-50 psi (2.76-3.45 bar)

Feed water

  • Feed Water Source: RO Permeate
  • Feed Water Conductivity (Equivalent including CO₂): < 40 micro S/cm
  • Silica (SiO₂): < 1 ppm
  • Iron, Mn, Sulfite: < 0.01 ppm
  • Total Chlorine/Chloramine: < 0.02 PPM
  • Hardness: < 1.0 ppm
  • Dissolved Organics: < 0.5 ppm
  • Operating pH range: 4 – 11
  • Operating Temperature: 41 – 113°F (5 – 45C)
  • Inlet Pressure: < 100 psi (7 bar)

Mechanical / hydraulic

  • Design Product Flow:
    • LX24MK: 12.5 gpm (2.8 m³/h)
    • LX30MK: 15 gpm (3.3 m³/h)
  • Pressure Rating: 100 PSIG (7 bar)
  • Operating Temperature Rating: 113°F (45°C)
  • Dilute In/Product Process Connections: 1 ¼” BSP Male w/ O-Ring seals
  • Concentrate In/Reject Process Connections: ¾” BSPT Male w/ O-Ring seals