Datasheet summary
LX-X
Engineering summary from PDF text extraction for LX-X. Verify every value with the OEM datasheet.
Summary
Product identification
Ionpure® LX-X Industrial Continuous Electrodeionization (CEDI) Modules are designed to generate mixed-bed quality deionized water for industrial applications without the use of chemicals. They are suitable for power, HPI/CPI, general electronics, food and beverage, and laboratory applications.
Key features include:
- Double O-ring seal guarantees leak-free operation
- Generate mixed-bed quality deionized water without the use of chemicals
- No need for acid/caustic, neutralization system or exchangable DI tanks
- Continuous production instead of batch, with consistent quality
- Superior electrical isolation
- Proprietary “all-filled” concentrating compartments eliminate recirculation pump and brine injection
- Significantly lower operating costs than conventional ion exchange
The modules are CE marked, factory tested to meet strict industry standards, and manufactured under ISO 9001 and ISO 14000 quality and environmental management systems.
Operating limits
- Continuous operation: 100 psi (7 bar), 113˚F (45˚C)
- Maximum ambient room temperature: 113°F (45°C)
- Installation: indoors with no direct sunlight
- Recovery: 90 – 95%
- Maximum Feed Pressure: 100 psi (7 bar)
- Pressure Drop Range at Nominal Flow: 20 - 30 psi (1.4 - 2.1 bar)
- Maximum Feed Temperature: 113˚F (45˚C)
Feed water
- Source: RO permeate
- Feed Water Conductivity Equivalent, including CO₂ and Silica: < 40 μS/cm
- Temperature: 41 – 113˚F (5 – 45˚C)
- Inlet Pressure: 100 psi (7 bar)
- Maximum Total Chlorine (as Cl₂): < 0.02 ppm
- Iron (as Fe): < 0.01 ppm
- Manganese (as Mn): < 0.01 ppm
- Sulfide (S²⁻): < 0.01 ppm
- pH: 4 – 11
- Total Hardness (as CaCO₃): < 1.0 ppm
- Dissolved Organics (TOC as C): < 0.5 ppm
- Silica (SiO₂): < 1.0 ppm
Product water
- Product Resistivity: > 16 megohm-cm*
- Silica (SiO₂) Removal: 90 – 99%, depending on feed conditions *Actual performance may be determined using the IP-Pro projection software available from Ionpure.
Electrical
- DC Voltage: 0 – 600
- DC Amperage: 0 - 6.0
Mechanical / hydraulic
Flow and Physical Specifications
| Model Number | Product Flow min. gpm (m3/hr) | Product Flow nominal gpm (m3/hr) | Product Flow max. gpm (m3/hr) | Shipping Weight lbs (kg) | Operating Weight lbs (kg) |
|---|---|---|---|---|---|
| IP-LXM04X | 1.0 (0.22) | 2.0 (0.44) | 3.0 (0.67) | 150 (68) | 100 (45) |
| IP-LXM10X | 2.5 (0.55) | 5.0 (1.1) | 7.5 (1.65) | 200 (91) | 150 (68) |
| IP-LXM18X | 4.5 (1.1) | 9.0 (2.0) | 13.5 (3.1) | 220 (100) | 170 (77) |
| IP-LXM24X | 6.3 (1.4) | 12.5 (2.8) | 18.8 (4.2) | 250 (113) | 200 (91) |
| IP-LXM30X | 7.5 (1.65) | 15.0 (3.3) | 22.5 (5.11) | 270 (123) | 220 (100) |
| IP-LXM45X | 11.3 (2.55) | 22.5 (5.1) | 33.8 (7.67) | 320 (145) | 270 (122.5) |
Physical Specifications
| Item Number | Dimensions L +/- 0.25” (6.4 mm) | Dimensions C +/- 0.13” (3.2 mm) |
|---|---|---|
| LXM04X | 10.12” (257 mm) | 5.78” (146.8 mm) |
| LXM10X | 13.69” (347.7 mm) | 9.28” (235.7 mm) |
| LXM18X | 19.22” (488.2 mm) | 13.93” (353.8 mm) |
| LXM24X | 23.69” (601.7 mm) | 17.43” (442.7 mm) |
| LXM30X | 27.42” (696.5 mm) | 20.92” (531.3 mm) |
| LXM45X | 35.72” (907.3 mm) | 29.44” (747.7 mm) |
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the most recent revisions of the product datasheet. For contractual data, please refer to the official OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.