Datasheet summary
15 kW
Engineering summary from PDF text extraction for 15 kW. Verify every value with the OEM datasheet.
Summary
Product identification
This document describes the O-008D: 15kW DC Power Supply designed for Electropure™ brand EDI modules by SnowPure.
Operating limits
- Designed for continuous operation at rated output
- Over-current and short-circuit protection
- Over-temperature protection
- Suitable for NEMA Enclosures
- Designed for use with:
- EXL-750 x 3 to 4 modules (0-600VDC, operates at 400VDC)
- EXL-850 x 3 to 4 modules (0-600VDC, operates at 500VDC)
Electrical
- Output DC Voltage (Constant Voltage Mode): 0-600 VDC
- Output DC Current (Has Overcurrent Protection): 0-24 Amps DC
- AC Input:
- Three phase, 50 or 60HZ
- Specify 400V (380-440V) or 480V (440-480V) at order
- Protection:
- Over-Current (Lowers Operating Voltage): @24.1 ADC
- Over-Current (Shutdown/Fault): @24.2 ADC
- Short-Circuit (Shutdown/Fault): Open Circuit
- Over-Temperature (Standby/Fault): Included
- Voltage Ripple, Max: < 3% (1-2%)
- Power Efficiency Rating (@Full Load): > 94%
- System Interfaces & Options:
- Standard 0-10VDC Set Value Input
- Optional: 4-20mA Set Value Input (O-016A)
- Available: Remote digital DC Volt/Ammeter display (O-014B)
- Actual Voltage and Current: 0-10Vdc input, 4-20mA output
- Interlock by dry normally open contact (flow switch/pressure switch)
- Main input contactor “On/Off” (customer)
- Interlock “Open/Closed” (customer)
- Fault Indicator (customer)
- Other Electrical Features:
- Air-cooled, Switch-mode DC supply
- Low AC ripple
- Power semiconductors for pulse amplitude modulation
- Electronics for constant voltage control
- CE Compliant (IEC EN61558-2-16, EN61558-1)
- EMC filter to protect against mains line noise
- Isolation transformer built into the power supply
Mechanical / Hydraulic
- Cooling: Speed Controlled Fan (Inlet: Front, Outlet: Rear)
- Dimensions (Width x Depth x Height):
- 17x17.5x10 inches
- 43.2x44.5x25.4 cm
- Operating Weight:
- 67 lbs
- 31 kg
- Degree of Protection: NEMA 2
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.