Back to SUEZ E-Cell Electrodeionization EDI / EDR modules
SUEZ logo

Datasheet summary

2020-2L-2S

Engineering summary from PDF text extraction for 2020-2L-2S. Verify every value with the OEM datasheet.

Summary

Product Identification

The SUEZ 2020 Electrodialysis Reversal (EDR) system is a proven desalination technology.

EDR Features

  • Use of Carbon Electrodes results in no gas produced and no separate electrode stream required.
  • High Water Recovery, up to 94%
  • Salt Removal of 50 to 95%
  • Polarity Reversal self-cleaning with electricity
  • Free chlorine tolerance
  • Tolerance to moderate suspended solids
  • Adjustable product water performance without blending
  • Ability to disassemble stacks for inspection
  • Silica tolerance

EDR Benefits

  • Efficient use of scarce water resources
  • Low pretreatment requirements and costs
  • Low chemical consumption costs
  • Long membrane life, typically 10+ years
  • Strong ability to recover from less than ideal feed water quality

Standard Design and Scope of Supply

  • MK-IV-2 EDR stacks with SUEZ Carbon Electrodes
  • Cartridge filter
  • Concentrate Recirculation pump with VFD
  • GE Fanuc Micro PLC & 12” (30 cm) color Quick Panel HMI
  • Full Owners Operation & Maintenance Manual, Factory Acceptance Test results and Stack Performance Test results

Instrumentation - Transmitters

  • Flow: Product Outlet, Concentrate Outlet
  • Pressure: Cartridge Filter Inlet & Outlet, Concentrate, Recirculation Pump Outlet, Product Outlet
  • Conductivity: Inlet & Product Outlet

Operating Limits

  • Water Recovery: Up to 94%
  • Salt Removal: 50% to 95%
  • Silica Removal: none
  • Temperature: 40 to 100ºF (4 To 38ºC)
  • Maximum Feed Pressure: 50 psi
  • Input Voltage: 480VAC/3/60Hz

Feed Water Requirements

Continuous Levels

  • Typical Feed TDS: 100 to 3,000 ppm (mg/l)
  • Maximum Feed TDS: 12,000 ppm (mg/l)
  • Silica (Reactive): unlimited
  • pH: 2 to 10
  • SDI (5 min. test): 10
  • Turbidity: < 0.5 NTU
  • Free Chlorine: 0.5 ppm (mg/l)
  • TOC: < 15 ppm (mg/l)
  • COD: < 50 ppm (mg/l) as O2
  • Iron: < 0.3 ppm (mg/l)
  • Manganese, Aluminum: < 0.1 ppm (mg/l)
  • H₂S: < 0.1 ppm (mg/l)

Allowable Intermittent Levels

  • SDI (5 min. test): 15
  • Turbidity: 2.0 NTU
  • Free Chlorine: 30 mg/l

Mechanical / Hydraulic

Material of Construction

  • Welded Frame: Painted Carbon Steel
  • Dilute and Concentrate Piping: Sch. 80 PVC
  • Flanges: ANSI
  • Concentrate Pump: Single-stage Centrifugal
  • Rectifier: NEMA 3R
  • Control Panel: NEMA 4

Quality Assurance

  • Certification: UL
  • Facility: ISO 9001:2000

EDR 2020 2 & 4 Line Standard Systems

2020-2L-2S

  • Product Flow Nominal: 280 gpm (63.6 m³/h)
  • Product Flow Range: 165 to 325 gpm (37.5 to 73.8 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product
  • Electrode Outlet Flow: 2.2 gpm (8.3 lpm)
  • Number of Stacks: 4
  • Number of Lines: 2
  • Number of Stages: 2
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 90” x 309” (2.3 x 7.9 m)
  • Inlet Piping: 4” (10 cm)
  • Product Outlet Piping: 4” (10 cm)
  • Off-Spec Outlet Piping: 4” (10 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 1.5” (4 cm)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 46A
    • Stage 2: 518VDC, 18A
  • Connection Requirement (Includes Feed pump): 140 KVA

2020-2L-3S

  • Product Flow Nominal: 260 gpm (59.1 m³/h)
  • Product Flow Range: 165 to 270 gpm (37.5 to 61.3 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product
  • Electrode Outlet Flow: 2.5 gpm (9.5 lpm)
  • Number of Stacks: 6
  • Number of Lines: 2
  • Number of Stages: 3
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 90” x 375” (2.3 x 9.5 m)
  • Inlet Piping: 4” (10 cm)
  • Product Outlet Piping: 4” (10 cm)
  • Off-Spec Outlet Piping: 4” (10 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 1.5” (4 cm)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 26A
    • Stage 2: 518VDC, 14A
    • Stage 3: 420VDC, 7.5A
  • Connection Requirement (Includes Feed pump): 107 KVA

2020-4L-2S

  • Product Flow Nominal: 560 gpm (127.2 m³/h)
  • Product Flow Range: 325 to 655 gpm (73.8 to 148.8 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product
  • Electrode Outlet Flow: 4.3 gpm (16.3 lpm)
  • Number of Stacks: 8
  • Number of Lines: 4
  • Number of Stages: 2
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 169” x 493” (4.3 x 12.5 m)
  • Inlet Piping: 6” (15 cm)
  • Product Outlet Piping: 6” (15 cm)
  • Off-Spec Outlet Piping: 6” (15 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 2” (5 cm)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 46A
    • Stage 2: 518VDC, 18A
  • Connection Requirement (Includes Feed pump): 276 KVA

2020-4L-3S

  • Product Flow Nominal: 520 gpm (118.2 m³/h)
  • Product Flow Range: 325 to 545 gpm (73.8 to 123.8 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product
  • Electrode Outlet Flow: 5.0 gpm (19 lpm)
  • Number of Stacks: 12
  • Number of Lines: 4
  • Number of Stages: 3
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 169” x 625” (4.3 x 15.9 m)
  • Inlet Piping: 6” (15 cm)
  • Product Outlet Piping: 6” (15 cm)
  • Off-Spec Outlet Piping: 6” (15 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 2” (5 CM)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 26A
    • Stage 2: 518VDC, 14A
    • Stage 3: 420VDC, 7.5A
  • Connection Requirement (Includes Feed pump): 209 KVA

Note: all piping sizes are provided for nominal flow rates at 85% recovery.

EDR 2020 6 & 8 Line Standard Systems

2020-6L-2S

  • Product Flow Nominal: 840 gpm (190.8 m³/h)
  • Product Flow Range: 485 to 985 gpm (110.2 to 223.7 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product flow rate
  • Electrode Outlet Flow: 6.5 gpm (25 lpm)
  • Number of Stacks: 12
  • Number of Lines: 6
  • Number of Stages: 2
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 270” x 493” (6.0 x 12.5 m)
  • Inlet Piping: 8” (20 cm)
  • Product Outlet Piping: 8” (20 cm)
  • Off-Spec Outlet Piping: 8” (20 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 3” (8 cm)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 46A
    • Stage 2: 518VDC, 18A
  • Connection Requirement (Includes Feed pump): 380 KVA

2020-6L-3S

  • Product Flow Nominal: 780 gpm (177.2 m³/h)
  • Product Flow Range: 485 to 820 gpm (110.2 to 186.2 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product flow rate
  • Electrode Outlet Flow: 7.5 gpm (28 lpm)
  • Number of Stacks: 18
  • Number of Lines: 6
  • Number of Stages: 3
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 270” x 625” (6.0 x 15.9 m)
  • Inlet Piping: 8” (20 cm)
  • Product Outlet Piping: 8” (20 cm)
  • Off-Spec Outlet Piping: 8” (20 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 3” (8 cm)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 26A
    • Stage 2: 518VDC, 14A
    • Stage 3: 420VDC, 7.5A
  • Connection Requirement (Includes Feed pump): 285 KVA

2020-8L-2S

  • Product Flow Nominal: 1120 gpm (254.4 m³/h)
  • Product Flow Range: 645 to 1315 gpm (146.5 to 298.7 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product flow rate
  • Electrode Outlet Flow: 8.7 gpm (33 lpm)
  • Number of Stacks: 16
  • Number of Lines: 8
  • Number of Stages: 2
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 270” x 493” (6.0 x 12.5 m)
  • Inlet Piping: 8” (20 cm)
  • Product Outlet Piping: 8” (20 cm)
  • Off-Spec Outlet Piping: 8” (20 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 3” (8 cm)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 46A
    • Stage 2: 518VDC, 18A
  • Connection Requirement (Includes Feed pump): 542 KVA

2020-8L-3S

  • Product Flow Nominal: 1040 gpm (236.2 m³/h)
  • Product Flow Range: 645 to 1090 gpm (146.5 to 247.6 m³/h)
  • Concentrate Outlet Flow: Depends on recovery and product flow rate
  • Electrode Outlet Flow: 10 gpm (38 lpm)
  • Number of Stacks: 24
  • Number of Lines: 8
  • Number of Stages: 3
  • Type of Stack: MK-IV-2
  • System Dimensions (Width x Length): 270” x 625” (6.0 x 15.9 m)
  • Inlet Piping: 8” (20 cm)
  • Product Outlet Piping: 8” (20 cm)
  • Off-Spec Outlet Piping: 8” (20 cm)
  • Electrode Outlet Piping: 3” (8 cm)
  • Concentrate Outlet Piping: 3” (8 cm)
  • Maximum Rectifier Output (Per Stack Basis):
    • Stage 1: 590VDC, 26A
    • Stage 2: 518VDC, 14A
    • Stage 3: 420VDC, 7.5A
  • Connection Requirement (Includes Feed pump): 397 KVA

Note: all piping sizes are provided for nominal flow rates at 85% recovery.

Electrical

  • Typical Power Consumption: 2 – 4 kWh/1,000 gallons of product water

Performance, number of stages and cell pairs, recovery and power consumption are dependent on inlet feed water quality and temperature. A Watsys projection must be completed by an authorized SUEZ Water Technologies & Solutions design representative for proper system design & for any performance guarantee to be provided.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.