Back to SUEZ E-Cell Electrodeionization EDI / EDR modules
SUEZ logo

Datasheet summary

ECell 3X-2

Engineering summary from PDF text extraction for ECell 3X-2. Verify every value with the OEM datasheet.

Summary

Product identification

  • E-Cell 3X Standard Systems with 1 to 12 stacks
  • Flow range of 15 – 336 gpm (3.4 - 76.3 m³/h)
  • Certification: UL, CSA
  • Facility Certification: ISO 9001:2000
  • Full Factory Acceptance Test (FAT) completed on each system before shipment.

Operating limits

  • Temperature: 40 to 104ºF (4.4 to 40ºC)
  • Feed Pressure: 60 to 100 psi (4.1 to 6.9 bar)
  • Dilute Pressure Drop: 20 to 40 psi (1.4 to 2.8 bar)
  • Recovery: Up to 95%
  • Performance, flow rate per stack, recovery and power consumption are dependent on inlet feed water quality and temperature. An E-Calc projection is required for proper system design and performance guarantees.

Feed water

  • Total Exchangeable Anions (TEA) (as CaCO₃) Including CO₂ as calculated by E-Calc: < 25.0 ppm
  • pH: 4 – 11
  • Hardness (as CaCO₃): < 1.0 ppm
  • Silica (Reactive): < 1.0 ppm
  • SDI (15 min): < 1
  • TOC: < 0.5 ppm
  • Total Chlorine: < 0.05 ppm
  • Fe, Mn, H₂S: <0.01 ppm

Product water

  • Outlet (Dilute) Product Quality: > 16 MOhm-cm
  • Outlet Product Silica Guarantee: Down to < 5ppb

Electrical

  • Rectifier compatible with: 400VAC & 50Hz or 460VAC & 60Hz
  • Input Voltage: 460VAC 60Hz, 400VAC 50Hz
  • Control Panel Power: 24VDC
  • Features: Individual stack current monitoring
  • Model Specifics:
ModelMaximum Output @ 400VDCConnection Requirement
ECell3X-210.4 Amps13 kVA
ECell3X-420.8 Amps21 kVA
ECell3X-841.6 Amps36 kVA
ECell3X-1262.4 Amps52 kVA

Mechanical / hydraulic

  • Base system features:
    • Flow & pressure transmitters, ability to connect to SCADA system
  • System options:
    • Allen Bradley Micrologix PLC with Ethernet (Includes SUEZ 6” Color QuickPanel View HMI)
    • NEMA 4 Terminal Box (removal of PLC & HMI, all wiring terminated at terminal box)
    • Standard Instrumentation:
      • Burkert Paddlewheel flow sensors on Dilute, Concentrate, and Electrode Outlet
      • Burkert pressure transmitters on all streams
      • Burkert conductivity analyzer and sensor on Dilute Outlet
    • Premium Instrumentation:
      • Rosemount vortex flow transmitters on Dilute and Concentrate Outlet
      • Burkert Paddlewheel flow sensor on Electrode Outlet
      • Burkert pressure transmitters on all streams
      • Rosemount conductivity analyzer and sensor on Dilute Outlet
    • Inlet Divert Valve: Burkert (Standard Instrumentation) or Rosemount (Premium Instrumentation)
    • ANSI to DIN conversion kits
  • Instrumentation (Monitored points):
    • Flow: Dilute (Product) Outlet, Concentrate Outlet, Electrode Outlet
    • Pressure: Dilute Inlet, Dilute Outlet, Concentrate Inlet, Concentrate Outlet, Electrode Outlet
    • Resistivity (optional): Dilute Inlet, Dilute Outlet
  • Material of construction & ratings:
    • Welded Frame: Painted Carbon Steel
    • Dilute Piping: Sch. 80 PVC
    • Concentrate Piping: Sch. 80 PVC
    • Flanges: ANSI
    • Rectifier: NEMA 4
    • Control Panel: NEMA 4
  • Model Specifics:
ModelNumber of StacksProduct Flow NominalRangeConcentrate Outlet Flow*Electrode Outlet Flow (Nominal)
ECell3X-21 - 244 gpm (10 m³/h)15 – 56 gpm (3.4 – 12.7 m³/h)0.83 - 7.67 gpm (0.19 - 1.74 m³/h)0.70 gpm (0.16 m³/h)
ECell3X-43 - 488 gpm (20 m³/h)45 - 112 gpm (10.2 – 25.4 m³/h)2.50 - 15.34 gpm (0.57 - 3.48 m³/h)1.40 gpm (0.32 m³/h)
ECell3X-85 - 8176 gpm (40 m³/h)75 - 224 gpm (17.0 – 50.9 m³/h)4.17 - 30.67 gpm (0.95 - 6.97 m³/h)2.80 gpm (0.64 m³/h)
ECell3X-1210 - 12264 gpm (59.9 m³/h)150 - 336 gpm (34.0 – 76.3 m³/h)8.34 - 46.01 gpm (1.89 - 10.45 m³/h)4.20 gpm (0.95 m³/h)

*Concentrate outlet flow depends on recovery and product flow. Range shown is at 95% max recovery and minimal product flow of 15gpm/stack to 87% recovery and maximum product flow of 28gpm/stack.

  • Dimensions and Piping:
ModelOverall Dimensions (W x L x H)Inlet PipingProduct Outlet PipingRinse Outlet PipingConcentrate Outlet PipingElectrode Outlet PipingShipping Weight (Approx.)
ECell3X-242” x 50” x 84” (1.1m x 1.3m x 2.2m)2.0”1.5”1.5”0.75”0.5”2050 lb / 925 kg
ECell3X-446” x 75” x 84” (1.1m x 1.9m x 2.2m)2.5”2.5”2.5”1.0”0.5”3075 lb / 1400 kg
ECell3X-864” x 103” x 90” (1.7m x 2.6m x 2.3m)4”3”3”1.5”0.5”5250 lb / 2400 kg
ECell3X-1264” x 130” x 90” (1.7m x 3.3m x 2.3m)4”4”4”1.5”0.5”6190 lb / 3125 kg

All piping sizes are provided for nominal flow rates at 90% recovery.


Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the most recent revisions. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.