Datasheet summary
ECell 3X-2
Engineering summary from PDF text extraction for ECell 3X-2. Verify every value with the OEM datasheet.
Summary
Product identification
- E-Cell 3X Standard Systems with 1 to 12 stacks
- Flow range of 15 – 336 gpm (3.4 - 76.3 m³/h)
- Certification: UL, CSA
- Facility Certification: ISO 9001:2000
- Full Factory Acceptance Test (FAT) completed on each system before shipment.
Operating limits
- Temperature: 40 to 104ºF (4.4 to 40ºC)
- Feed Pressure: 60 to 100 psi (4.1 to 6.9 bar)
- Dilute Pressure Drop: 20 to 40 psi (1.4 to 2.8 bar)
- Recovery: Up to 95%
- Performance, flow rate per stack, recovery and power consumption are dependent on inlet feed water quality and temperature. An E-Calc projection is required for proper system design and performance guarantees.
Feed water
- Total Exchangeable Anions (TEA) (as CaCO₃) Including CO₂ as calculated by E-Calc: < 25.0 ppm
- pH: 4 – 11
- Hardness (as CaCO₃): < 1.0 ppm
- Silica (Reactive): < 1.0 ppm
- SDI (15 min): < 1
- TOC: < 0.5 ppm
- Total Chlorine: < 0.05 ppm
- Fe, Mn, H₂S: <0.01 ppm
Product water
- Outlet (Dilute) Product Quality: > 16 MOhm-cm
- Outlet Product Silica Guarantee: Down to < 5ppb
Electrical
- Rectifier compatible with: 400VAC & 50Hz or 460VAC & 60Hz
- Input Voltage: 460VAC 60Hz, 400VAC 50Hz
- Control Panel Power: 24VDC
- Features: Individual stack current monitoring
- Model Specifics:
| Model | Maximum Output @ 400VDC | Connection Requirement |
|---|---|---|
| ECell3X-2 | 10.4 Amps | 13 kVA |
| ECell3X-4 | 20.8 Amps | 21 kVA |
| ECell3X-8 | 41.6 Amps | 36 kVA |
| ECell3X-12 | 62.4 Amps | 52 kVA |
Mechanical / hydraulic
- Base system features:
- Flow & pressure transmitters, ability to connect to SCADA system
- System options:
- Allen Bradley Micrologix PLC with Ethernet (Includes SUEZ 6” Color QuickPanel View HMI)
- NEMA 4 Terminal Box (removal of PLC & HMI, all wiring terminated at terminal box)
- Standard Instrumentation:
- Burkert Paddlewheel flow sensors on Dilute, Concentrate, and Electrode Outlet
- Burkert pressure transmitters on all streams
- Burkert conductivity analyzer and sensor on Dilute Outlet
- Premium Instrumentation:
- Rosemount vortex flow transmitters on Dilute and Concentrate Outlet
- Burkert Paddlewheel flow sensor on Electrode Outlet
- Burkert pressure transmitters on all streams
- Rosemount conductivity analyzer and sensor on Dilute Outlet
- Inlet Divert Valve: Burkert (Standard Instrumentation) or Rosemount (Premium Instrumentation)
- ANSI to DIN conversion kits
- Instrumentation (Monitored points):
- Flow: Dilute (Product) Outlet, Concentrate Outlet, Electrode Outlet
- Pressure: Dilute Inlet, Dilute Outlet, Concentrate Inlet, Concentrate Outlet, Electrode Outlet
- Resistivity (optional): Dilute Inlet, Dilute Outlet
- Material of construction & ratings:
- Welded Frame: Painted Carbon Steel
- Dilute Piping: Sch. 80 PVC
- Concentrate Piping: Sch. 80 PVC
- Flanges: ANSI
- Rectifier: NEMA 4
- Control Panel: NEMA 4
- Model Specifics:
| Model | Number of Stacks | Product Flow Nominal | Range | Concentrate Outlet Flow* | Electrode Outlet Flow (Nominal) |
|---|---|---|---|---|---|
| ECell3X-2 | 1 - 2 | 44 gpm (10 m³/h) | 15 – 56 gpm (3.4 – 12.7 m³/h) | 0.83 - 7.67 gpm (0.19 - 1.74 m³/h) | 0.70 gpm (0.16 m³/h) |
| ECell3X-4 | 3 - 4 | 88 gpm (20 m³/h) | 45 - 112 gpm (10.2 – 25.4 m³/h) | 2.50 - 15.34 gpm (0.57 - 3.48 m³/h) | 1.40 gpm (0.32 m³/h) |
| ECell3X-8 | 5 - 8 | 176 gpm (40 m³/h) | 75 - 224 gpm (17.0 – 50.9 m³/h) | 4.17 - 30.67 gpm (0.95 - 6.97 m³/h) | 2.80 gpm (0.64 m³/h) |
| ECell3X-12 | 10 - 12 | 264 gpm (59.9 m³/h) | 150 - 336 gpm (34.0 – 76.3 m³/h) | 8.34 - 46.01 gpm (1.89 - 10.45 m³/h) | 4.20 gpm (0.95 m³/h) |
*Concentrate outlet flow depends on recovery and product flow. Range shown is at 95% max recovery and minimal product flow of 15gpm/stack to 87% recovery and maximum product flow of 28gpm/stack.
- Dimensions and Piping:
| Model | Overall Dimensions (W x L x H) | Inlet Piping | Product Outlet Piping | Rinse Outlet Piping | Concentrate Outlet Piping | Electrode Outlet Piping | Shipping Weight (Approx.) |
|---|---|---|---|---|---|---|---|
| ECell3X-2 | 42” x 50” x 84” (1.1m x 1.3m x 2.2m) | 2.0” | 1.5” | 1.5” | 0.75” | 0.5” | 2050 lb / 925 kg |
| ECell3X-4 | 46” x 75” x 84” (1.1m x 1.9m x 2.2m) | 2.5” | 2.5” | 2.5” | 1.0” | 0.5” | 3075 lb / 1400 kg |
| ECell3X-8 | 64” x 103” x 90” (1.7m x 2.6m x 2.3m) | 4” | 3” | 3” | 1.5” | 0.5” | 5250 lb / 2400 kg |
| ECell3X-12 | 64” x 130” x 90” (1.7m x 3.3m x 2.3m) | 4” | 4” | 4” | 1.5” | 0.5” | 6190 lb / 3125 kg |
All piping sizes are provided for nominal flow rates at 90% recovery.
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the most recent revisions. Contractual data must match the specific OEM PDF revision used on the project.