Back to SUEZ E-Cell Electrodeionization EDI / EDR modules
SUEZ logo

Datasheet summary

SUEZ MK3-1 EU

Engineering summary from PDF text extraction for SUEZ MK3-1 EU. Verify every value with the OEM datasheet.

Summary

Product identification

The E-Cell EU Standard Systems, combining E-Cell and Ionics EDI technology, are designed for reliable, long-term trouble-free operation with straightforward control. These systems utilize MK-3 stacks and are available in configurations from 1 to 12 stacks.

Models:

  • SUEZMK3-1 EU
  • SUEZMK3-3 EU
  • SUEZMK3-6 EU
  • SUEZMK3-9 EU
  • SUEZMK3-12 EU

Quality Assurance:

  • Certification: CE Marked
  • Facility: ISO 9001:2000
  • Full Factory Acceptance Test (FAT) completed on each system before shipment.

Key Features:

  • MK-3 E-Cell stacks simplify system design by removing the need for concentrate recirculation and brine injection.
  • Low energy design of MK-3 E-Cell stacks reduces electrical requirements and operating costs.
  • Concentrate flow in the opposite direction to the Dilute flow allows operation at higher hardness concentrations for longer periods.
  • Siemens S1200 PLC and HMI.
  • Automatic Outlet Divert Valve.
  • Includes Owners Operation & Maintenance Manual, Factory Acceptance Test results, and Stack Performance Test results.
  • Direct Current Variable Freq. Drive (DC Drive).
  • Premium models available with additional features like flow & pressure transmitters and SCADA connectivity.
  • A Premium Model Option allows for the removal of PLC & HMI, with all wiring terminated at an IP55 Junction Box.

Operating limits

  • Temperature: 4.4 to 40 °C (40 to 104 °F)
  • Feed Pressure: 4.7 to 6.9 bar (70 to 100 psi)
  • Dilute Pressure Drop: 1.4 to 2.4 bar (20 to 35 psi)
  • Recovery: Up to 95%

Feed water requirements

  • Total Exchangeable Anions (TEA including CO₂ as calculated by E-Calc): < 25.0 ppm (as CaCO₃)
  • pH: 5 – 9
  • Hardness: < 1.0 ppm (as CaCO₃)
  • Silica (Reactive): < 1.0 ppm
  • SDI (15 min): < 1
  • TOC: < 0.5 ppm
  • Total Chlorine: < 0.05 ppm
  • Fe, Mn, H₂S: <0.01 ppm

Product water

  • Outlet (Dilute) Product Quality: > 16 MOhm-cm
  • Outlet Product Silica Guarantee: Down to < 5ppb

Electrical

  • Input Voltage: 400 VAC/3/50Hz
  • Control Panel Power: 24VDC
  • DC Drive: IP55
  • Control Panel: IP55
  • Typical Power Consumption: 0.13 – 0.26 kWh/m³ (0.5 – 1.0 kWh/1000gal)
ModelMaximum Output @ 300VDCConnection Requirement
SUEZMK3-1 EU5.2Amps3.5 KVA
SUEZMK3-3 EU15.6Amps8 KVA
SUEZMK3-6 EU31.2Amps15 KVA
SUEZMK3-9 EU46.8Amps22 KVA
SUEZMK3-12 EU62.4Amps29 KVA

Mechanical / hydraulic

General Information:

ModelNumber of StacksType of Stack
SUEZMK3-1 EU1MK-3
SUEZMK3-3 EU2 - 3MK-3
SUEZMK3-6 EU4 - 6MK-3
SUEZMK3-9 EU6 – 9MK-3
SUEZMK3-12 EU10 - 12MK-3

Flow Rates:

ModelProduct Flow NominalProduct Flow RangeConcentrate Outlet FlowElectrode Outlet Flow
SUEZMK3-1 EU3.4 m³/h2.3-4.5 m³/h (10-20 gpm)3.4-5.7 lpm (0.91-1.5 gpm)1.3 lpm (0.35 gpm)
SUEZMK3-3 EU10.2 m³/h6.8-13.6 m³/h (30-60 gpm)11.0-17.8 lpm (2.9-4.7 gpm)4.0 lpm (1.05 gpm)
SUEZMK3-6 EU20.4 m³/h13.6-27.3 m³/h (60-120 gpm)22.0-35.6 lpm (5.8-9.4 gpm)7.9 lpm (2.10 gpm)
SUEZMK3-9 EU30.6 m³/h20.4-40.9 m³/h (90-180 gpm)33.3-53.4 lpm (8.8-14.1 gpm)11.9 lpm (3.15 gpm)
SUEZMK3-12 EU40.8 m³/h27.3-54.5 m³/h (120-240 gpm)44.3-71.2 lpm (11.7-18.8 gpm)15.9 lpm (4.2 gpm)
All piping sizes are provided for nominal flow rates at 90% recovery.

Dimensions:

ModelOverall System Dimensions (Width x Length x Height)Inlet PipingProduct Outlet PipingRinse Outlet PipingElectrode Outlet PipingConcentrate Outlet Piping
SUEZMK3-1 EU0.9m x 1.4m x 1.8m (36”x54”x72”)DN25DN25DN25DN15DN15
SUEZMK3-3 EU1.2m x 2.2m x 2.1m (46”x86”x84”)DN50DN50DN50DN15DN15
SUEZMK3-6 EU1.2m x 2.7m x 2.1m (46”x107”x84”)DN80DN80DN80DN15DN20
SUEZMK3-9 EU1.2m x 3.4m x 2.1m (46”x132”x84”)DN100DN100DN100DN15DN25
SUEZMK3-12 EU1.2m x 3.7m x 2.1m (46”x146”x84”)DN100DN100DN100DN15DN40

Shipping Weight:

ModelShipping Weight
SUEZMK3-1 EU454 kg (1000 lbs)
SUEZMK3-3 EU1134 kg (2500 lbs)
SUEZMK3-6 EU1588 kg (3500 lbs)
SUEZMK3-9 EU1950 kg (4300 lbs)
SUEZMK3-12 EU2268 kg (5000 lbs)

Material of Construction:

  • Welded Frame: Painted Carbon Steel
  • Dilute Piping: PPL
  • Concentrate Piping: PVC
  • Flanges: DIN

Instrumentation:

  • Flow: Dilute (Product) Outlet, Concentrate Outlet, Electrode Outlet
  • Pressure: Dilute Inlet, Dilute Outlet, Concentrate Inlet, Concentrate Outlet, Electrode Outlet
  • Resistivity: Dilute (Product) Outlet

Performance, flow rate per stack, recovery and power consumption are dependent on inlet feed water quality and temperature. An E-Calc projection must be completed for proper system design & for any performance guarantee to be provided.


Disclaimer: This summary is based on extracted text from an OEM PDF datasheet. It may not include all figures, footnotes, or the latest revisions. For contractual purposes, data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.