Datasheet summary
SUEZ MK3-1 EU
Engineering summary from PDF text extraction for SUEZ MK3-1 EU. Verify every value with the OEM datasheet.
Summary
Product identification
The E-Cell EU Standard Systems, combining E-Cell and Ionics EDI technology, are designed for reliable, long-term trouble-free operation with straightforward control. These systems utilize MK-3 stacks and are available in configurations from 1 to 12 stacks.
Models:
- SUEZMK3-1 EU
- SUEZMK3-3 EU
- SUEZMK3-6 EU
- SUEZMK3-9 EU
- SUEZMK3-12 EU
Quality Assurance:
- Certification: CE Marked
- Facility: ISO 9001:2000
- Full Factory Acceptance Test (FAT) completed on each system before shipment.
Key Features:
- MK-3 E-Cell stacks simplify system design by removing the need for concentrate recirculation and brine injection.
- Low energy design of MK-3 E-Cell stacks reduces electrical requirements and operating costs.
- Concentrate flow in the opposite direction to the Dilute flow allows operation at higher hardness concentrations for longer periods.
- Siemens S1200 PLC and HMI.
- Automatic Outlet Divert Valve.
- Includes Owners Operation & Maintenance Manual, Factory Acceptance Test results, and Stack Performance Test results.
- Direct Current Variable Freq. Drive (DC Drive).
- Premium models available with additional features like flow & pressure transmitters and SCADA connectivity.
- A Premium Model Option allows for the removal of PLC & HMI, with all wiring terminated at an IP55 Junction Box.
Operating limits
- Temperature: 4.4 to 40 °C (40 to 104 °F)
- Feed Pressure: 4.7 to 6.9 bar (70 to 100 psi)
- Dilute Pressure Drop: 1.4 to 2.4 bar (20 to 35 psi)
- Recovery: Up to 95%
Feed water requirements
- Total Exchangeable Anions (TEA including CO₂ as calculated by E-Calc): < 25.0 ppm (as CaCO₃)
- pH: 5 – 9
- Hardness: < 1.0 ppm (as CaCO₃)
- Silica (Reactive): < 1.0 ppm
- SDI (15 min): < 1
- TOC: < 0.5 ppm
- Total Chlorine: < 0.05 ppm
- Fe, Mn, H₂S: <0.01 ppm
Product water
- Outlet (Dilute) Product Quality: > 16 MOhm-cm
- Outlet Product Silica Guarantee: Down to < 5ppb
Electrical
- Input Voltage: 400 VAC/3/50Hz
- Control Panel Power: 24VDC
- DC Drive: IP55
- Control Panel: IP55
- Typical Power Consumption: 0.13 – 0.26 kWh/m³ (0.5 – 1.0 kWh/1000gal)
| Model | Maximum Output @ 300VDC | Connection Requirement |
|---|---|---|
| SUEZMK3-1 EU | 5.2Amps | 3.5 KVA |
| SUEZMK3-3 EU | 15.6Amps | 8 KVA |
| SUEZMK3-6 EU | 31.2Amps | 15 KVA |
| SUEZMK3-9 EU | 46.8Amps | 22 KVA |
| SUEZMK3-12 EU | 62.4Amps | 29 KVA |
Mechanical / hydraulic
General Information:
| Model | Number of Stacks | Type of Stack |
|---|---|---|
| SUEZMK3-1 EU | 1 | MK-3 |
| SUEZMK3-3 EU | 2 - 3 | MK-3 |
| SUEZMK3-6 EU | 4 - 6 | MK-3 |
| SUEZMK3-9 EU | 6 – 9 | MK-3 |
| SUEZMK3-12 EU | 10 - 12 | MK-3 |
Flow Rates:
| Model | Product Flow Nominal | Product Flow Range | Concentrate Outlet Flow | Electrode Outlet Flow |
|---|---|---|---|---|
| SUEZMK3-1 EU | 3.4 m³/h | 2.3-4.5 m³/h (10-20 gpm) | 3.4-5.7 lpm (0.91-1.5 gpm) | 1.3 lpm (0.35 gpm) |
| SUEZMK3-3 EU | 10.2 m³/h | 6.8-13.6 m³/h (30-60 gpm) | 11.0-17.8 lpm (2.9-4.7 gpm) | 4.0 lpm (1.05 gpm) |
| SUEZMK3-6 EU | 20.4 m³/h | 13.6-27.3 m³/h (60-120 gpm) | 22.0-35.6 lpm (5.8-9.4 gpm) | 7.9 lpm (2.10 gpm) |
| SUEZMK3-9 EU | 30.6 m³/h | 20.4-40.9 m³/h (90-180 gpm) | 33.3-53.4 lpm (8.8-14.1 gpm) | 11.9 lpm (3.15 gpm) |
| SUEZMK3-12 EU | 40.8 m³/h | 27.3-54.5 m³/h (120-240 gpm) | 44.3-71.2 lpm (11.7-18.8 gpm) | 15.9 lpm (4.2 gpm) |
| All piping sizes are provided for nominal flow rates at 90% recovery. |
Dimensions:
| Model | Overall System Dimensions (Width x Length x Height) | Inlet Piping | Product Outlet Piping | Rinse Outlet Piping | Electrode Outlet Piping | Concentrate Outlet Piping |
|---|---|---|---|---|---|---|
| SUEZMK3-1 EU | 0.9m x 1.4m x 1.8m (36”x54”x72”) | DN25 | DN25 | DN25 | DN15 | DN15 |
| SUEZMK3-3 EU | 1.2m x 2.2m x 2.1m (46”x86”x84”) | DN50 | DN50 | DN50 | DN15 | DN15 |
| SUEZMK3-6 EU | 1.2m x 2.7m x 2.1m (46”x107”x84”) | DN80 | DN80 | DN80 | DN15 | DN20 |
| SUEZMK3-9 EU | 1.2m x 3.4m x 2.1m (46”x132”x84”) | DN100 | DN100 | DN100 | DN15 | DN25 |
| SUEZMK3-12 EU | 1.2m x 3.7m x 2.1m (46”x146”x84”) | DN100 | DN100 | DN100 | DN15 | DN40 |
Shipping Weight:
| Model | Shipping Weight |
|---|---|
| SUEZMK3-1 EU | 454 kg (1000 lbs) |
| SUEZMK3-3 EU | 1134 kg (2500 lbs) |
| SUEZMK3-6 EU | 1588 kg (3500 lbs) |
| SUEZMK3-9 EU | 1950 kg (4300 lbs) |
| SUEZMK3-12 EU | 2268 kg (5000 lbs) |
Material of Construction:
- Welded Frame: Painted Carbon Steel
- Dilute Piping: PPL
- Concentrate Piping: PVC
- Flanges: DIN
Instrumentation:
- Flow: Dilute (Product) Outlet, Concentrate Outlet, Electrode Outlet
- Pressure: Dilute Inlet, Dilute Outlet, Concentrate Inlet, Concentrate Outlet, Electrode Outlet
- Resistivity: Dilute (Product) Outlet
Performance, flow rate per stack, recovery and power consumption are dependent on inlet feed water quality and temperature. An E-Calc projection must be completed for proper system design & for any performance guarantee to be provided.
Disclaimer: This summary is based on extracted text from an OEM PDF datasheet. It may not include all figures, footnotes, or the latest revisions. For contractual purposes, data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.