Back to Veolia E-Cell-EDI / EDR
Veolia logo

Datasheet summary

EDI AM Pro E-Cell EU Series

Engineering summary from PDF text extraction for EDI AM Pro E-Cell EU Series. Verify every value with the OEM datasheet.

Summary

PRO E-Cell Series Integrated RO/EDI Machines

The PRO E-Cell Series features integrated Reverse Osmosis (RO) and Electrodeionization (EDI) systems mounted on a common skid, designed for capacities of 50 to 200 gpm at 60 Hz.

Features

  • RO and EDI mounted on common skid
  • PRO E-Cell 50 and 100 models feature 2-pass RO designs.
  • PRO E-Cell 150 and 200 models feature 1-pass RO designs.
  • RO Pump VFD(s) and EDI DC Drive mounted on skid.
  • RO permeate flush sequence on shutdown and divert to drain on startup.
  • Allen Bradley control system with Compact Logix PLC and PanelView Plus 1000 interface.
  • UL/cUL Electrical Panel.

Instrumentation

  • Flow Meters: RO Permeate, RO Concentrate, EDI Product, EDI Concentrate, EDI Electrode
  • Pressure Gauge: Pre-& Post Cartridge Filter, Primary, Final, inter stage, RO Permeate, RO Concentrate, RO Pump Discharge
  • Pressure Switch: RO Feed, RO Permeate, RO Concentrate
  • Pressure Transmitter: RO Primary, RO Final, RO Permeate, EDI Product, EDI Concentrate, EDI Electrode, EDI Dilute Feed
  • pH Meter: RO Feed pass 1 (also pass 2 for 50-100 model)
  • ORP (Optional): RO Feed pass 1

Accessories

  • PRO Multi-Media filters
  • PRO Activated Carbon and Softeners
  • PRO Clean-in-Place units
  • PRO Chemical Feed Systems
  • Transfer Pumps and Storage Tanks

Operating Limits

  • Design Recovery RO1: 75% Pass 1; 85% Pass 2 (Recovery Rate can vary +/- 5%)
  • Design Recovery EDI: 90-95%
  • Design Temperature: 60ºF (16ºC)
  • Operating Temperature Range: 40-85ºF (5-29ºC)
  • System Inlet Pressure: 30-60 PSI (2-4 Bar)

Materials of Construction

  • High-pressure piping: 316 Stainless Steel, Sch. 10
  • Low-pressure RO & EDI piping: PVC, Sch. 80
  • Frame: Epoxy-coated carbon steel
  • Enclosure: Nema 4 carbon steel
  • Clamps/fittings: Zinc-plated

Membrane Elements and Housings

  • Model (50-100): Veolia AK-400
  • Model (150-200): Veolia PRO-RO-400-HR-WT
  • Average membrane flux (50-100): 12 GFD pass 1, 21 GFD pass 2
  • Average membrane flux (150-200): 14 GFD
  • Membrane rejection: 99.0 to 99.5%
  • Housing material: Fiberglass
  • Housing Pressure Rating: 450 psi

EDI Stacks

  • Model: Veolia E-Cell MK-3X
  • Stack product flow rate, nom: 16.7 gpm (3.8 m3/hr)
  • Performance: 16 MOhm-cm
  • Silica Removal: <10 ppb

Cartridge Filtration

  • Housing model: Veolia HX-0740-80-V316
  • Housing material: 316 Stainless Steel
  • Cartridge filter: 1-µ nom, ROSave.Zs*, RO.Zs01-40XK

PRO E-Cell Models

PRO E-Cell 50DP

  • RO Permeate Rate: 52.5 gpm (11.9 m3/hr)
  • RO Concentrate Rate: 21 gpm (4.8 m3/hr)
  • Concentrate Recycle: 10 gpm (2.3 m3/hr)
  • RO Feed Rate: 74 gpm (16.8 m3/hr)
  • EDI Product Rate: 50 gpm (11.4 m3/hr)
  • EDI Concentrate Rate (max): 1.6 gpm (0.36 m3/hr)
  • EDI Electrode Rate: 1 gpm (0.23 m3/hr)
  • Pumps and Motors: Veolia/Tonkaflo SS8512 Pass 1 (20HP/15KW), SS8512 Pass 2 (20HP/15KW); Quantity: 2; Installed Power: 30 KW
  • Membrane Elements: Quantity: 20 Pass 1; 12 Pass 2. Housing Style: 4 element long, 4 port. Banking Arrangement: 3→2 Pass 1; 2→1 Pass 2
  • EDI Stacks: Model: Veolia E-Cell MK-3X; Quantity: 2; Power (DC drive, 300 VDC): 16 A max
  • Cartridge Filtration: Housing Model: HX-0740-3.0-V-316; Housing Quantity: 1; Cartridge Filter Model: ROSave.Zs, RO.Zs01-40XK; Cartridge Filter Length: 40-inch (120 cm); Cartridge Filter Qty: 7
  • Skid Dimensions: Height: 96” (244 cm); Width: 72” (183 cm); Length: 197” (500 cm)
  • Skid Weights: Shipping Weight: 9050 lb. (4150 kg); Operating Weight: 11150 lb. (5100 kg)

PRO E-Cell 100DP

  • RO Permeate Rate: 105 gpm (23.9 m3/hr)
  • RO Concentrate Rate: 42 gpm (9.5 m3/hr)
  • Concentrate Recycle: 10 gpm (2.3 m3/hr)
  • RO Feed Rate: 147 gpm (33.4 m3/hr)
  • EDI Product Rate: 100 gpm (22.7 m3/hr)
  • EDI Concentrate Rate (max): 3.2 gpm (0.73 m3/hr)
  • EDI Electrode Rate: 2.1 gpm (0.48 m3/hr)
  • Pumps and Motors: Veolia /Tonkaflo SS24007 Pass 1 (50 Hp/37 KW), SS12509 Pass 2 (30 Hp/22.5 KW); Quantity: 2; Installed Power: 60 KW
  • Membrane Elements: Quantity: 36 Pass 1; 18 Pass 2. Housing Style: 6 element long, 4 port. Banking Arrangement: 4→2 Pass 1; 2→1 Pass 2
  • EDI Stacks: Model: Veolia E-Cell MK-3X; Quantity: 4; Power (DC drive, 300 VDC): 31.2 A max
  • Cartridge Filtration: Housing Model: HX-0740-3.0-V-316; Housing Quantity: 2; Cartridge Filter Model: ROSave.Zs, RO.Zs01-40XK; Cartridge Filter Length: 40-inch (102 cm); Cartridge Filter Qty: 14
  • Skid Dimensions: Height: 96” (244 cm); Width: 58” (147 cm); Length: 277” (704 cm)
  • Skid Weights: Shipping Weight: 13650 lb. (6250 kg); Operating Weight: 17050 lb. (7750 kg)

PRO E-Cell 150

  • RO Permeate Rate: 158 gpm (36 m3/hr)
  • RO Concentrate Rate: 52.7 gpm (12 m3/hr)
  • Concentrate Recycle: NA
  • RO Feed Rate: 211 gpm (48 m3/hr)
  • EDI Product Rate: 150 gpm (34 m3/hr)
  • EDI Concentrate Rate (max): 4.7 gpm (1.1 m3/hr)
  • EDI Electrode Rate: 3.2 gpm (0.73 m3/hr)
  • Pumps and Motors: Veolia /Tonkaflo SS24009 (60 Hp/45 KW); Quantity: 1; Installed Power: 45 KW
  • Membrane Elements: Quantity: 42. Housing Style: 6 element long, 4 port. Banking Arrangement: 5→2
  • EDI Stacks: Model: Veolia E-Cell MK-3X; Quantity: 6; Power (DC drive, 300 VDC): 46.8 A max
  • Cartridge Filtration: Housing Model: HX-0740-3.0-V-316; Housing Quantity: 2; Cartridge Filter Model: ROSave.Zs, RO.Zs01-40XK; Cartridge Filter Length: 40-inch (102 cm); Cartridge Filter Qty: 14
  • Skid Dimensions: Height: 90” (229 cm); Width: 80” (203 cm); Length: 282” (716 cm)
  • Skid Weights: Shipping Weight: 12350 lb. (5650 kg); Operating Weight: 15200 lb. (6950 kg)

PRO E-Cell 200

  • RO Permeate Rate: 210 gpm (48 m3/hr)
  • RO Concentrate Rate: 70 gpm (16 m3/hr)
  • Concentrate Recycle: NA
  • RO Feed Rate: 280 gpm (63.6 m3/hr)
  • EDI Product Rate: 200 gpm (45 m3/hr)
  • EDI Concentrate Rate (max): 6.3 gpm (1.4 m3/hr)
  • EDI Electrode Rate: 4.2 gpm (0.95 m3/hr)
  • Pumps and Motors: Veolia /Tonkaflo AS40409 (75 Hp/56.3 KW); Quantity: 1; Installed Power: 56.3 KW
  • Membrane Elements: Quantity: 54. Housing Style: 6 element long, 4 port. Banking Arrangement: 6→3
  • EDI Stacks: Model: Veolia E-Cell MK-3X; Quantity: 8; Power (DC drive, 300 VDC): 62.4 A max
  • Cartridge Filtration: Housing Model: HX-0740-3.0-V-316; Housing Quantity: 2; Cartridge Filter Model: ROSave.Zs, RO.Zs01-40XK; Cartridge Filter Length: 40-inch (102 cm); Cartridge Filter Qty: 14
  • Skid Dimensions: Height: 90” (229 cm); Width: 80” (203 cm); Length: 282” (716 cm)
  • Skid Weights: Shipping Weight: 14600 lb. (6650 kg); Operating Weight: 18250 lb. (8300 kg)

Note on Permeate Rate: Maximum permeate rate listed at design temperature. Permeate rate can be reduced by up to 15%.

Installation and Utility Requirements

Mechanical / Hydraulic Connections

  • RO Inlet: 3” ANSI flange (50DP, 100DP); 4” ANSI flange (150, 200)
  • RO Reject to Drain: 1.5” ANSI flange (50DP, 150); 2” ANSI flange (100DP, 200)
  • RO Product Dump: 1.5” ANSI flange (50DP); 3” ANSI flange (100DP, 150); 4” ANSI flange (200)
  • EDI Product Outlet: 1.5” ANSI flange (50DP); 3” ANSI flange (100DP, 150); 4” ANSI flange (200)
  • EDI Product Dump: 1.5” ANSI flange (50DP); 3” ANSI flange (100DP, 150); 4” ANSI flange (200)
  • EDI Concentrate Outlet: 0.5” ANSI flange (all models)
  • EDI Electrode Outlet: 0.5” ANSI flange (all models)

Feed Water

  • Inlet Water Pressure: 30-60 psig (all models)

Electrical

  • Power: 460 VAC, 3-phase, 60Hz (all models)
  • Control Circuit: 120 VAC, 1-phase, 60Hz (all models)

Other Utilities

  • Air Pressure: 80 psi, oil-free (all models)
  • Drain to be Sized for: 95 gpm (22 m3/hr) (50DP); 150 gpm (35 m3/hr) (100DP); 220 gpm (50 m3/hr) (150); 280 gpm (64 m3/hr) (200)

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the official OEM PDF document revision used on your project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.