Summary

Product Identification

ECell3X EU EDI Systems are available with 1 to 12 stacks for a flow range of 3.4 - 76.3 m³/h.

Base System Features

  • ECell3X Systems with 1 to 12 stacks for flow range of 3.4 - 76.3 m³/h
  • Power supply compatible with 400VAC/50Hz
  • Individual stack current monitoring
  • Flow & pressure transmitters, ability to connect to control system
  • IP55 Terminal Box - all wiring terminated at terminal box
  • Standard Instrumentation package:
    • Burkert Paddlewheel flow sensors on Dilute Out, Concentrate Out, and Electrode Outlet
    • Burkert Resistivity analyzer and sensor on Dilute Outlet
    • Endress + Hauser pressure transmitters on all streams

Optional Features

  • Premium Instrumentation package:
    • Endress + Hauser Vortex flow transmitters on Dilute and Concentrate Outlet
    • Endress + Hauser conductivity analyzer and sensor on Dilute Outlet
    • Endress + Hauser pressure transmitters on all streams
  • Dilute Inlet Divert Valve Assembly
  • Control Panel including Siemens S7 1200 PLC with TP 1200 HMI

Quality Assurance

  • Certification: CE
  • Facility: ISO 9001:2000
  • Full Factory Acceptance Test (FAT) completed on each system before shipment.

Instrumentation

  • Flow: Dilute (Product) Outlet, Concentrate Outlet, Electrode Outlet
  • Pressure: Dilute Inlet, Dilute Outlet, Concentrate Inlet, Concentrate Outlet, Electrode Outlet
  • Resistivity: Dilute Inlet (optional), Dilute Outlet

Feed Water Requirements

  • Total Exchangeable Anions (as CaCO₃) (TEA) Including CO₂ as calculated by E-Calc: < 25.0 ppm
  • pH: 4 – 11
  • Hardness (as CaCO₃): < 1.0 ppm
  • Silica (Reactive): < 1.0 ppm
  • SDI (15 min): < 1
  • TOC: < 0.5 ppm
  • Total Chlorine: < 0.05 ppm
  • Fe, Mn, H₂S: <0.01 ppm

Operating Limits

  • Outlet (Dilute) Product Quality: > 16 MOhm-cm
  • Outlet Product Silica Guarantee: Down to < 5ppb
  • Recovery: Up to 95%
  • Temperature: 4.4 to 40ºC
  • Feed Pressure: 4.1 to 6.9 bar
  • Dilute Pressure Drop: 1.4 to 2.8 bar
  • Input Voltage: 400VAC 50Hz

Note 1: Performance, flow rate per stack, recovery, and power consumption are all dependent on inlet feed water quality and temperature. An E-Calc projection must be completed for proper system design & for any performance guarantee to be provided.

Material of Construction & Ratings

  • Welded Frame: Painted Carbon Steel
  • Dilute Piping: Sch. 80 PVC
  • Concentrate Piping: Sch. 80 PVC
  • Flanges: DIN
  • Power Panel: IP55
  • Control Panel/Terminal Box: IP55
  • Control Panel Power: 24VDC

System Specifications by Model

E-Cell3X-2

  • Number of Stacks: 1 - 2
  • Type of stack: E-Cell-3X
  • Flow Rates:
    • Product Flow Nominal: 10 m³/h
    • Range: 3.4 – 12.7 m³/h
    • Concentrate Outlet Flow: 0.19 - 1.74 m³/h
    • Electrode Outlet Flow (Nominal): 0.16 m³/h
  • Dimensions:
    • Overall Dimensions (Width x Length x Height): 1.1m x 1.3m x 2.2m
    • Inlet Piping: DN50
    • Product Outlet Piping: DN40
    • Rinse Outlet Piping: DN40
    • Concentrate Outlet Piping: DN20
    • Electrode Outlet Piping: DN15
  • Shipping Weight (Approx.): 925 kg
  • Electrical:
    • Maximum Output @ 400VDC: 10.4 Amps
    • Connection Requirement: 13 kVA

E-Cell3X-4

  • Number of Stacks: 3 - 4
  • Type of stack: E-Cell-3X
  • Flow Rates:
    • Product Flow Nominal: 20 m³/h
    • Range: 10.2 – 25.4 m³/h
    • Concentrate Outlet Flow: 0.57 - 3.48 m³/h
    • Electrode Outlet Flow (Nominal): 0.32 m³/h
  • Dimensions:
    • Overall Dimensions (Width x Length x Height): 1.1m x 1.9m x 2.2m
    • Inlet Piping: DN65
    • Product Outlet Piping: DN65
    • Rinse Outlet Piping: DN65
    • Concentrate Outlet Piping: DN25
    • Electrode Outlet Piping: DN15
  • Shipping Weight (Approx.): 1400 kg
  • Electrical:
    • Maximum Output @ 400VDC: 20.8 Amps
    • Connection Requirement: 21 kVA

E-Cell3X-8

  • Number of Stacks: 5 - 8
  • Type of stack: E-Cell-3X
  • Flow Rates:
    • Product Flow Nominal: 40 m³/h
    • Range: 17.0 – 50.9 m³/h
    • Concentrate Outlet Flow: 0.95 - 6.97 m³/h
    • Electrode Outlet Flow (Nominal): 0.64 m³/h
  • Dimensions:
    • Overall Dimensions (Width x Length x Height): 1.7m x 2.6m x 2.3m
    • Inlet Piping: DN100
    • Product Outlet Piping: DN80
    • Rinse Outlet Piping: DN80
    • Concentrate Outlet Piping: DN40
    • Electrode Outlet Piping: DN15
  • Shipping Weight (Approx.): 2400 kg
  • Electrical:
    • Maximum Output @ 400VDC: 41.6 Amps
    • Connection Requirement: 36 kVA

E-Cell3X-12

  • Number of Stacks: 10 - 12
  • Type of stack: E-Cell-3X
  • Flow Rates:
    • Product Flow Nominal: 60 m³/h
    • Range: 34.0 – 76.3 m³/h
    • Concentrate Outlet Flow: 1.89 - 10.45 m³/h
    • Electrode Outlet Flow (Nominal): 0.95 m³/h
  • Dimensions:
    • Overall Dimensions (Width x Length x Height): 1.7m x 3.3m x 2.3m
    • Inlet Piping: DN100
    • Product Outlet Piping: DN100
    • Rinse Outlet Piping: DN100
    • Concentrate Outlet Piping: DN40
    • Electrode Outlet Piping: DN15
  • Shipping Weight (Approx.): 3125 kg
  • Electrical:
    • Maximum Output @ 400VDC: 62.4 Amps
    • Connection Requirement: 52 kVA

Note: All piping sizes are provided for nominal flow rates at 90% recovery. Note 2: Concentrate outlet flow at 95% max recovery and minimal product flow of 3.4m³/h/stack to 87% recovery and maximum product flow of 6.4m³/h/stack.