Back to Veolia E-Cell-EDI / EDR
Veolia logo

Datasheet summary

EDI E-Cell 3X Standard

Engineering summary from PDF text extraction for EDI E-Cell 3X Standard. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: E-Cell 3X Standard Systems
  • Stack Range: 1 to 12 stacks
  • Flow Range: 15 – 336gpm (3.4 - 76.3 m3/h)
  • Certifications: UL, CSA
  • Manufacturing Facility: ISO 9001:2000
  • Full Factory Acceptance Test (FAT) completed on each system before shipment.

Operating limits

  • Temperature: 40 to 104ºF (4.4 to 40ºC)
  • Feed Pressure: 60 to 100 psi (4.1 to 6.9 bar)
  • Dilute Pressure Drop: 20 to 40 psi (1.4 to 2.8 bar)
  • Recovery: Up to 95%

Feed water

  • Total Exchangeable Anions (TEA) (as CaCO₃) Including CO₂ as calculated by E-Calc: < 25.0 ppm
  • pH: 4 – 11
  • Hardness (as CaCO₃): < 1.0 ppm
  • Silica (Reactive): < 1.0 ppm
  • SDI (15 min): < 1
  • TOC: < 0.5 ppm
  • Total Chlorine: < 0.05 ppm
  • Fe, Mn, H₂S: <0.01 ppm

Product water

  • Outlet (Dilute) Product Quality: > 16 MOhm-cm
  • Outlet Product Silica Guarantee: Down to < 5ppb

Electrical

  • Rectifier Compatibility: 400VAC & 50Hz or 460VAC & 60Hz
  • Input Voltage: 460VAC 60Hz, 400VAC 50Hz
  • Control Panel Power: 24VDC
  • Individual stack current monitoring.

Electrical Specifications per Model

  • ECell3X-2 (1 - 2 Stacks):
    • Maximum Output @ 400VDC: 10.4 Amps
    • Connection Requirement: 13 kVA
  • ECell3X-4 (3 - 4 Stacks):
    • Maximum Output @ 400VDC: 20.8 Amps
    • Connection Requirement: 21 kVA
  • ECell3X-8 (5 - 8 Stacks):
    • Maximum Output @ 400VDC: 41.6 Amps
    • Connection Requirement: 36 kVA
  • ECell3X-12 (10 - 12 Stacks):
    • Maximum Output @ 400VDC: 62.4 Amps
    • Connection Requirement: 52 kVA

Mechanical / hydraulic

  • Materials of Construction:
    • Welded Frame: Painted Carbon Steel
    • Dilute Piping: Sch. 80 PVC
    • Concentrate Piping: Sch. 80 PVC
    • Flanges: ANSI
    • Rectifier: NEMA 4
    • Control Panel: NEMA 4
  • Instrumentation:
    • Standard Instrumentation:
      • Burkert Paddlewheel flow sensors on Dilute, Concentrate, and Electrode Outlet
      • Burkert pressure transmitters on all streams
      • Burkert conductivity analyzer and sensor on Dilute Outlet
    • Premium Instrumentation:
      • Rosemount vortex flow transmitters on Dilute and Concentrate Outlet
      • Burkert Paddlewheel flow sensor on Electrode Outlet
      • Burkert pressure transmitters on all streams
      • Rosemount conductivity analyzer and sensor on Dilute Outlet
  • Optional Features:
    • Allen Bradley Micrologix PLC with Ethernet, includes Veolia 6” Color QuickPanel View HMI
    • NEMA 4 Terminal Box
    • Inlet Divert Valve (Burkert for Standard Instrumentation, Rosemount for Premium Instrumentation)
    • ANSI to DIN conversion kits
  • Monitored Streams:
    • Flow: Dilute (Product) Outlet, Concentrate Outlet, Electrode Outlet
    • Pressure: Dilute Inlet, Dilute Outlet, Concentrate Inlet, Concentrate Outlet, Electrode Outlet
    • Resistivity: Dilute Inlet (optional), Dilute Outlet

System Specifications per Model

  • ECell3X-2 (1 - 2 Stacks):
    • Product Flow Nominal: 44 gpm (10 m3/h)
    • Product Flow Range: 15 – 56 gpm (3.4 – 12.7 m3/h)
    • Concentrate Outlet Flow: 0.83 - 7.67 gpm (0.19 - 1.74 m3/h)
    • Electrode Outlet Flow (Nominal): 0.70 gpm (0.16 m3/h)
    • Overall Dimensions (W x L x H): 42” x 50” x 84” (1.1m x 1.3m x 2.2m)
    • Inlet Piping: 2.0”
    • Product Outlet Piping: 1.5”
    • Rinse Outlet Piping: 1.5”
    • Concentrate Outlet Piping: 0.75”
    • Electrode Outlet Piping: 0.5”
    • Shipping Weight (Approx.): 2050 lb / 925 kg
  • ECell3X-4 (3 - 4 Stacks):
    • Product Flow Nominal: 88 gpm (20 m3/h)
    • Product Flow Range: 45 - 112 gpm (10.2 – 25.4 m3/h)
    • Concentrate Outlet Flow: 2.50 - 15.34 gpm (0.57 - 3.48 m3/h)
    • Electrode Outlet Flow (Nominal): 1.40 gpm (0.32 m3/h)
    • Overall Dimensions (W x L x H): 46” x 75” x 84” (1.1m x 1.9m x 2.2m)
    • Inlet Piping: 2.5”
    • Product Outlet Piping: 2.5”
    • Rinse Outlet Piping: 2.5”
    • Concentrate Outlet Piping: 1.0”
    • Electrode Outlet Piping: 0.5”
    • Shipping Weight (Approx.): 3075 lb / 1400 kg
  • ECell3X-8 (5 - 8 Stacks):
    • Product Flow Nominal: 176 gpm (40 m3/h)
    • Product Flow Range: 75 - 224 gpm (17.0 – 50.9 m3/h)
    • Concentrate Outlet Flow: 4.17 - 30.67 gpm (0.95 - 6.97 m3/h)
    • Electrode Outlet Flow (Nominal): 2.80 gpm (0.64 m3/h)
    • Overall Dimensions (W x L x H): 64” x 103” x 90” (1.7m x 2.6m x 2.3m)
    • Inlet Piping: 4”
    • Product Outlet Piping: 3”
    • Rinse Outlet Piping: 3”
    • Concentrate Outlet Piping: 1.5”
    • Electrode Outlet Piping: 0.5”
    • Shipping Weight (Approx.): 5250 lb / 2400 kg
  • ECell3X-12 (10 - 12 Stacks):
    • Product Flow Nominal: 264 gpm (59.9 m3/h)
    • Product Flow Range: 150 - 336 gpm (34.0 – 76.3 m3/h)
    • Concentrate Outlet Flow: 8.34- 46.01 gpm (1.89 - 10.45 m3/h)
    • Electrode Outlet Flow (Nominal): 4.20 gpm (0.95 m3/h)
    • Overall Dimensions (W x L x H): 64” x 130” x 90” (1.7m x 3.3m x 2.3m)
    • Inlet Piping: 4”
    • Product Outlet Piping: 4”
    • Rinse Outlet Piping: 4”
    • Concentrate Outlet Piping: 1.5”
    • Electrode Outlet Piping: 0.5”
    • Shipping Weight (Approx.): 6190 lb / 3125 kg

All piping sizes are provided for nominal flow rates at 90% recovery.


Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)