Datasheet summary
Hot Water E-Cell Stack MK-3PharmHT
Engineering summary from PDF text extraction for Hot Water E-Cell Stack MK-3PharmHT. Verify every value with the OEM datasheet.
Summary
Product identification
The E-Cell* EDI MK-3PharmHT Stack is a hot water sanitizable electrodeionization (EDI) stack designed to provide ultrapure water for the pharmaceutical and biotechnology industries.
Key features include:
- Uses electrical current for ultrapure water production.
- Hot water sanitizable up to 185ºF (85ºC) for 160 cycles.
- Delivers high product water quality and low energy consumption.
- Minimizes cleaning requirements at higher feed water hardness levels using counter-current operation.
- Leak free, with a standard 3-year prorated warranty.
- Operates continuously, requiring no caustic or acid for regeneration of ion exchange resin.
- Requires no brine injection or concentrate recirculation.
Typical Applications: The product water from this stack can exceed USP, EP, and other pharmacopeia required quality levels in applications such as:
- Water for injection
- Pharmaceutical purified water
- Laboratory purified water systems
Quality Assurance:
- CE, RoHS, CSA and EAC marked
- Materials in contact with fluids meet FDA requirements
- Certified with UKCA
- Manufactured in an ISO 9001 and ISO 14001 facility
- Halal certified by the Islamic Food and Nutrition Council of America (IFANCA®)
Mechanical / Hydraulic
- Nominal Flow: 3.4 m3/h (15 gpm)
- Flow Rate Range: 1.6–5.4 m3/h (7.0–23.8 gpm)
- Shipping Weight: 100 kg (220 lbs)
- Dimensions (width x height x depth): 30 cm x 61 cm x 54 cm (12’’ x 24” x 22”)
Operating limits
- Recovery: Up to 96%
- Inlet Pressure: ≤ 6.9 bar (100 psi) (Determined by downstream pressure requirements, operation choice, and stack pressure drop.)
- Pressure Drop: 1.4–2.8 bar (20–40 psi) (At nominal flow and 25°C.)
- Hot Water Sanitization Cycles: 160
- Maximum Sanitization Temperature: 85ºC (185ºF)
- Maximum Sanitization Inlet Pressure: 2.1 bar (30 psi)
Product water
Guarantees available based on site conditions and design:
- Resistivity: ≥ 10 MOhm-cm
- Sodium: ≥ 99.9% removal
- Silica (SiO₂): Up to 99% removal
Electrical
- Voltage: 0–300 VDC
- Amperage: 0–5.2 ADC
Feed water
- Total Exchangeable Anions (TEA as CaCO₃): ≤ 63.6 ppm (At minimum flow and maximum temperature, represents all anions including OH⁻, CO₂, and SiO₂.)
- Conductivity Equivalent: ≤ 109 μS/cm
- Temperature: 4.4–40˚C (40–104˚F)
- Total Hardness (as CaCO₃): ≤ 1.0 ppm (Applies to standard counter-current flow. Decreases to 0.1 ppm in co-current flow.)
- Silica (SiO₂): ≤ 1.0 ppm (Allowable limit decreases above nominal flow and to 0.5 ppm with feed water hardness above 0.5 ppm as CaCO₃.)
- Total Organic Carbon (TOC as C): ≤ 0.5 ppm
- Total Chlorine: ≤ 0.05 ppm
- Fe, Mn, H₂S: ≤ 0.01 ppm
- Boron: ≤ 1.0 ppm (Limited to 0.3 ppm as B if a silica guarantee or resistivity guarantee above 10 MOhm-cm is required.)
- pH: 4 to 11
- Oil & Grease: None detectable
- Particulate: RO permeate (RO or equivalent feed water is required as EDI stacks contain packed beds of ion exchange medium that cannot be backwashed. Systems with an open system between RO and E-Cell must be fitted with filters, typically 5 µm absolute or 1 µm nominal, immediately preceding the E-Cell.)
- Oxidizing Agents: None detectable
- Color: ≤ 5 APHA (Defined by ASTM D1209.)
Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual purposes, please refer to the specific OEM PDF revision used on your project.