Back to Veolia E-Cell-EDI / EDR
Veolia logo

Datasheet summary

EDI Mobile EDI CE

Engineering summary from PDF text extraction for EDI Mobile EDI CE. Verify every value with the OEM datasheet.

Summary

Product identification

The document describes Mobile EDI Systems for water demineralisation, available in two primary models: Mobile EDI and CEDI. These units are designed for emergency, supplemental, or long-term requirements.

  • Mobile EDI
    • E-Cell Model: Veolia MK-3X
    • Systems on Board: 20x Veolia MK-3X E-Cells
  • CEDI
    • E-Cell Model: Ionpure CEDI
    • Systems on Board: 4x Ionpure CEDI units

Both systems are CE marked ISO container systems.

Operating limits

ParameterMobile EDICEDI
Max Water Temperature40°C (104°F)40°C (104°F)
Min Water Temperature5°C (41°F)5°C (41°F)
Inlet Pressure1 bar (15 psig) to 2 bar (30 psig)2 bar (30 psig) to 6 bar (87 psig)
Max Permeate Outlet Pressure2.5 bar (36 psig)4 bar (58 psig)
Inlet Total Hardness<0.5ppm<0.5ppm
Inlet Conductivity<20μS/cm<40μS/cm

Feed water

  • Influent Flowrate
    • Mobile EDI: Up to 120m³/hr (528 gpm)
    • CEDI: 55m³/hr (242 gpm)
  • Inlet Instrumentation
    • Mobile EDI: Pressure, pH, ORP, Conductivity, Temperature
    • CEDI: Flow, Pressure, Conductivity, Temperature

Product water

The systems produce demineralized water for typical applications such as boiler feed water, rinse water, and cleaning or processing water.

  • Product Flowrate
    • Mobile EDI: 25 – 100m³/hr (110 – 440 gpm)
    • CEDI: 50m³/hr (220 gpm)
  • Effluent Flowrate
    • Mobile EDI: Up to 100m³/hr (440 gpm)
    • CEDI: Up to 50m³/hr (220 gpm)
  • Typical Treated Water Results
    • Conductivity: <0.1 µS/cm for both models
    • Silica: <20ppb for both models
  • Outlet Instrumentation
    • Mobile EDI: Flow, Pressure, Conductivity, Silica
    • CEDI: Flow, Pressure, Conductivity, Temperature

The Mobile EDI system offers the following operating configurations:

  • Mode 1: 20 Stacks, Product up to 100m³/hr
  • Mode 2: 12 Stacks, Product up to 70m³/hr
  • Mode 3: 8 Stacks, Product up to 48m³/hr The CEDI system configuration is 4 CEDI units, Product up to 50m³/hr.

Electrical

ParameterMobile EDICEDI
Service400/460 VAC, 50/60 Hz, 3 Phase400 VAC, 50Hz, 3 Phase
Current loadsFLA at Mode 1 - 162/152.9AFLA – 83.5A
FLA at Mode 2 - 128/119A
FLA at Mode 3 - 111/102A
Connection Type1x Terminal box, Hard wire 120mm²1x Junction box, Hard wire 120mm²

Mechanical / Hydraulic

The Mobile EDI systems are designed for quick deployment and feature continuous monitoring instrumentation, including pressure, temperature, flow, and water quality.

  • Pre-Filter
    • Mobile EDI: 1 Micron Cartridge Filters
    • CEDI: N/A
  • Feed Pump
    • Mobile EDI: 22kW Centrifugal
    • CEDI: N/A
  • Onboard CIP/ EDI Waste recycle
    • Mobile EDI: 2.5m³ Tank / Pump
    • CEDI: N/A
  • Noise Levels
    • Mobile EDI: Up to 79dB
    • CEDI: -
  • PLC
    • Mobile EDI: Allen-Bradley
    • CEDI: Siemens/Mitsubishi

Connections

Connection PointMobile EDI (Connection Type: ANSI 150 Flange)CEDI (Connection Type: PN10/16 Flange)
EDI Feed Water Inlet6”DN100
EDI Product Water Outlet6”DN100
Concentrate OutletN/A¹DN32
EDI Waste Recycle Outlet2”N/A
Feed Bypass/ EDI Rinse out6”DN100
RO CIP return/ Tank fill4”N/A
Tank Drain/ Overflow4”DN100
PSV release4”N/A

¹Mobile EDI Concentrate is recycled to CIP tank.

Container Specifications

ParameterMobile EDICEDI
Container Size40ft, Hi Cube20ft, Hi Cube
Dimensions (l x w x h)12.2m x 2.4m x 2.9m (40ft x 7.9ft x 9.5ft)6m x 2.4m x 2.6m (20ft x 7.9ft x 9.5ft)
Gross shipping weight11,900 kg (26,200 lbs)5,000 kg (11,000 lbs)
Gross operating weight15,700 kg (34,600 lbs)6,000 kg (13,200 lbs)

Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, or more recent revisions. For contractual purposes, data must match the specific OEM PDF revision used on the project. All information is typical, and some unit variation is possible.