Datasheet summary
EDI Mobile EDI CE
Engineering summary from PDF text extraction for EDI Mobile EDI CE. Verify every value with the OEM datasheet.
Summary
Product identification
The document describes Mobile EDI Systems for water demineralisation, available in two primary models: Mobile EDI and CEDI. These units are designed for emergency, supplemental, or long-term requirements.
- Mobile EDI
- E-Cell Model: Veolia MK-3X
- Systems on Board: 20x Veolia MK-3X E-Cells
- CEDI
- E-Cell Model: Ionpure CEDI
- Systems on Board: 4x Ionpure CEDI units
Both systems are CE marked ISO container systems.
Operating limits
| Parameter | Mobile EDI | CEDI |
|---|---|---|
| Max Water Temperature | 40°C (104°F) | 40°C (104°F) |
| Min Water Temperature | 5°C (41°F) | 5°C (41°F) |
| Inlet Pressure | 1 bar (15 psig) to 2 bar (30 psig) | 2 bar (30 psig) to 6 bar (87 psig) |
| Max Permeate Outlet Pressure | 2.5 bar (36 psig) | 4 bar (58 psig) |
| Inlet Total Hardness | <0.5ppm | <0.5ppm |
| Inlet Conductivity | <20μS/cm | <40μS/cm |
Feed water
- Influent Flowrate
- Mobile EDI: Up to 120m³/hr (528 gpm)
- CEDI: 55m³/hr (242 gpm)
- Inlet Instrumentation
- Mobile EDI: Pressure, pH, ORP, Conductivity, Temperature
- CEDI: Flow, Pressure, Conductivity, Temperature
Product water
The systems produce demineralized water for typical applications such as boiler feed water, rinse water, and cleaning or processing water.
- Product Flowrate
- Mobile EDI: 25 – 100m³/hr (110 – 440 gpm)
- CEDI: 50m³/hr (220 gpm)
- Effluent Flowrate
- Mobile EDI: Up to 100m³/hr (440 gpm)
- CEDI: Up to 50m³/hr (220 gpm)
- Typical Treated Water Results
- Conductivity: <0.1 µS/cm for both models
- Silica: <20ppb for both models
- Outlet Instrumentation
- Mobile EDI: Flow, Pressure, Conductivity, Silica
- CEDI: Flow, Pressure, Conductivity, Temperature
The Mobile EDI system offers the following operating configurations:
- Mode 1: 20 Stacks, Product up to 100m³/hr
- Mode 2: 12 Stacks, Product up to 70m³/hr
- Mode 3: 8 Stacks, Product up to 48m³/hr The CEDI system configuration is 4 CEDI units, Product up to 50m³/hr.
Electrical
| Parameter | Mobile EDI | CEDI |
|---|---|---|
| Service | 400/460 VAC, 50/60 Hz, 3 Phase | 400 VAC, 50Hz, 3 Phase |
| Current loads | FLA at Mode 1 - 162/152.9A | FLA – 83.5A |
| FLA at Mode 2 - 128/119A | ||
| FLA at Mode 3 - 111/102A | ||
| Connection Type | 1x Terminal box, Hard wire 120mm² | 1x Junction box, Hard wire 120mm² |
Mechanical / Hydraulic
The Mobile EDI systems are designed for quick deployment and feature continuous monitoring instrumentation, including pressure, temperature, flow, and water quality.
- Pre-Filter
- Mobile EDI: 1 Micron Cartridge Filters
- CEDI: N/A
- Feed Pump
- Mobile EDI: 22kW Centrifugal
- CEDI: N/A
- Onboard CIP/ EDI Waste recycle
- Mobile EDI: 2.5m³ Tank / Pump
- CEDI: N/A
- Noise Levels
- Mobile EDI: Up to 79dB
- CEDI: -
- PLC
- Mobile EDI: Allen-Bradley
- CEDI: Siemens/Mitsubishi
Connections
| Connection Point | Mobile EDI (Connection Type: ANSI 150 Flange) | CEDI (Connection Type: PN10/16 Flange) |
|---|---|---|
| EDI Feed Water Inlet | 6” | DN100 |
| EDI Product Water Outlet | 6” | DN100 |
| Concentrate Outlet | N/A¹ | DN32 |
| EDI Waste Recycle Outlet | 2” | N/A |
| Feed Bypass/ EDI Rinse out | 6” | DN100 |
| RO CIP return/ Tank fill | 4” | N/A |
| Tank Drain/ Overflow | 4” | DN100 |
| PSV release | 4” | N/A |
¹Mobile EDI Concentrate is recycled to CIP tank.
Container Specifications
| Parameter | Mobile EDI | CEDI |
|---|---|---|
| Container Size | 40ft, Hi Cube | 20ft, Hi Cube |
| Dimensions (l x w x h) | 12.2m x 2.4m x 2.9m (40ft x 7.9ft x 9.5ft) | 6m x 2.4m x 2.6m (20ft x 7.9ft x 9.5ft) |
| Gross shipping weight | 11,900 kg (26,200 lbs) | 5,000 kg (11,000 lbs) |
| Gross operating weight | 15,700 kg (34,600 lbs) | 6,000 kg (13,200 lbs) |
Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, or more recent revisions. For contractual purposes, data must match the specific OEM PDF revision used on the project. All information is typical, and some unit variation is possible.