Summary
Product identification
- Model: BEL 16-s(2x4)-1200 psi (also referred to as 16s4-1200)
- Document Revision: 0 (Dated 15/08/2014)
Operating limits
- Max. allowable working pressure: 1200 psi (82.7 bar)
- Permeate internal pressure: 125 psi (8.6 bar)
- Operating temperature: Not to exceed 49°C (120°F)
Mechanical / hydraulic
- Drawing units: Millimeters (inches)
- Key dimensions:
- Peak bell diameter: 540 mm (21.26 in)
- Body diameter: 450 mm (17.72 in)
- Feed / Concentrate port: 4" victaulic
- Permeate port: 3" victaulic
- Other specified dimensions (refer to drawing for location):
- 403.9 mm (15.9 in)
- 173 mm (6.81 in)
- 305 mm (12 in)
- 15 mm (0.6 in) max.
- 243 mm (9.57 in)
- 60 mm (2.36 in)
- 460 mm (18.11 in)
- Screw hex head: DIN EN 24014 M8x100
- Supports: 3 supports required for length code - 4 and over.
- Saddles: The vessel is supplied with two straps for external saddles; saddles can be shimmed if required.
- Closing torque (Item 19): Not to exceed 2 Nm.
Important Notes and Warnings
- Dimensions L, P, M can be varied according to exact membrane type.
- Items 17 & 18 should be located on the feed side for membrane shimming.
- Item 13 is for downstream only.
- Never pressurize a pressure vessel that is not loaded with membrane elements.
- Wrong manifolding may cause an excessive pressure on ports, potentially leading to leaks.
- All dimensions are for reference only, not for construction unless certified.
- Do not scale the drawing.