8-E-1500-1M-to-8M R1

Engineering summary from PDF text extraction for 8-E-1500-1M-to-8M R1. Verify every value with the OEM datasheet.

Summary

Product Identification

This document describes the BEL8-E-1500 PSI RO PRESSURE VESSEL. It is an 8-inch end port pressure vessel designed for reverse osmosis applications.

Operating Limits

  • Max. allowable working pressure: 1500 psi (103.4 bar)
  • Permeate internal pressure not to exceed: 125 psi (8.6 bar)

Warning: Never pressurize a pressure vessel that was not loaded with membrane elements.

Mechanical / Hydraulic

  • Feed/Concentrate Port: 1.5" VICTAULIC
  • Permeate Port: 1.25" BSP-MALE (Permeate Ports Outlet)
  • Body Diameter Concentrate: 45 mm (1.77 in)
  • Support: 3 supports are required for length code -4 and over.
  • Number of Membrane Elements: Vessels can accommodate 1 to 8 membrane elements.
  • Dimensions: All dimensions are for reference only, not for construction unless certified. Drawing unit: mm (inches).
  • Shimming:
    • For membranes shimming (if needed), use disk spacers (item 17 & 18) on the feed side of the vessels.
    • Saddles can be shimmed if required.
  • Assembly: The vessel is supplied with two strap assembly.
  • ASME Code: ASME code SEC. X, RP stamped vessels are available as an option (contact for pricing).
  • Adapter Options:
    • Two Standard adapters
    • Standard & Solid (blind) adapter
  • Color Options:
    • Standard: white (RAL 9010)
    • Other RAL numbers available (contact for pricing)
  • Selectable Working Pressure Rates (PSI): 300, 450, 600, 1,000, 1,200, 1,500