Datasheet summary
8-S-1200-1M to 8M R11
Engineering summary from PDF text extraction for 8-S-1200-1M to 8M R11. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Type: RO Pressure Vessel
- Designation: BEL8 8" Side Port
- Drawing Number: BEL8-S-PV
- Typical Configuration Example: BEL8-S (4 x 2.5") – 1,000 - 7M (indicating 4 ports with 2.5" diameter, 1,000 PSI working pressure, and 7 membrane elements).
Operating limits
- Maximum Permeate Internal Pressure: 125 psi (8.6 bar)
- Maximum Operating Temperature: 49°C (120°F)
- Available Working Pressure Rates: 300, 450, 600, 1,000, 1,200, 1,500 PSI
Mechanical / hydraulic
- Vessel Diameter: Ø202.2 mm (7.96 in)
- Feed/Concentrate Ports:
- Available sizes (Victaulic): 1.5", 2", 2.5", 3", 4"
- Note: Ports with 2.5", 3", or 4" diameter cannot be mounted 90° from any other port.
- Permeate Ports:
- Standard: 1.5" NPT male (I.D. 30 mm [1.18 in])
- Options: 1.5" Victaulic grooved, 1" BSP female
- Membrane Element Capacity: Designed to hold 1 to 8 membrane elements.
- Construction Details:
- Fasteners: M8x70 hex head screws (DIN 933 or DIN EN 24017)
- Supplied with two strap assemblies.
- Adapters: Standard (two provided), or an option for one standard and one solid (blind) adapter.
- Color: Standard white (RAL 9010); other RAL colors available upon request.
- ASME Code: Available with ASME code SEC. X, RP stamped vessel (contact for pricing).
- General Drawing Dimensions: See the official PDF for exact tabulated values and detailed drawing dimensions, which are provided for reference only and not for construction unless certified.
Disclaimer: This summary is based solely on the provided text extract. It may miss figures, footnotes, or revisions present in the full OEM PDF. Contractual data must match the specific OEM PDF revision used on the project.