Datasheet summary
eq-codeline-pressure-vessels-codeline-80e45
Engineering summary from PDF text extraction for 80E45. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: 80E45 Fiberglass RO Pressure Vessel
- Intended Use: Housing for reverse osmosis membrane elements to desalt typical brackish waters. Accommodates any make of eight-inch nominal diameter spiral-wound element.
Operating limits
- Design Pressure: 450 PSI at 120°F (3.1 MPa @ 49°C)
- Minimum Operating Temperature: 20°F (-7°C)
- Factory Test Pressure:
- CE: 675 PSI (4.65 MPa)
- ASME: 585 PSI (4 MPa)
- Burst Pressure: 2700 PSI (18.6 MPa)
- Maximum Permeate Pressure: 125 psi at 120°F (0.9 MPa @ 49°C)
- Operating pH Range: 3 to 10
Feed water
- Suitable for typical brackish waters.
- Operating pH Range: 3 to 10
Mechanical / hydraulic
- Accommodates any make of eight-inch nominal diameter spiral-wound element.
- Fiberglass shell expansion under pressure:
- ΔDIA = 0.02 in. (0.5 mm)
- ΔL = 0.2 in. (5 mm) for a length code –6 vessel
- Maximum weight of branch piping supported by ports:
- Feed/Concentrate: 16 lbs (7 kg)
- Permeate: 8 lbs (4 kg)
Precautions
- Read, understand, and follow all instructions; failure to take every precaution will void warranty and may result in vessel failure.
- Mount the shell on horizontal members at span "S" using compliant vessel supports furnished; tighten hold-down straps just snug.
- Provide overpressure protection for the vessel set at not more than 105% of design pressure.
- Inspect end closures regularly; replace components that have deteriorated and correct causes of corrosion.
- Do not make rigid piping connections to ports or clamp the vessel in any way that resists growth of the fiberglass shell under pressure.
- Do not hang piping manifolds from ports or use the vessel in any way to support other components.
- Do not operate the vessel at pressures and temperatures in excess of its rating.
- Do not operate the vessel without permeate ports internally connected with a complete set of elements and interconnecting hardware.
- Do not operate the vessel with permeate pressure in excess of 125 psi at 120°F (0.9 MPa @ 49°C).
- Do not overtighten the connection to the permeate port (hand-tighten plus one-quarter turn, check for leaks).
- Do not tolerate leaks or allow end closures to be routinely wetted in any way.
- Do not pressurize the vessel until double-checking to verify that the retaining ring is completely inside the groove.
- Do not work on any component until first verifying that pressure is relieved from the vessel.
- Do not operate at pH levels below 3 or above 10.
Ordering Information
When ordering, specify:
- Vessel length code (e.g., -1 to -7).
- Membrane brand and specific model (adapters will be supplied).
- Required certification: ASME Stamped and National Board Registered (consult factory for pricing), CE Marked, or Standard (Certified by Pentair Water).
- Exterior finish: Standard white high-gloss polyurethane coating, or optional colors (for 50 or more vessels per order, consult factory).
- Material options: Standard (as per drawing 99112) or customer-specified materials (consult factory for pricing and lead-time).
Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, or revisions. For contractual data, always refer to the specific OEM PDF revision used on the project.