Back to Codeline Pressure Vessels
CodeLine logo

Datasheet summary

80H15

Engineering summary from PDF text extraction for 80H15. Verify every value with the OEM datasheet.

Summary

Product identification

The CodeLine 80H15 is a fiberglass reverse osmosis (RO) pressure vessel designed for continuous, long-term use as housing for RO membrane elements. It is intended to desalt typical brackish waters at pressures up to 150 psi. This vessel accommodates any make of eight-inch nominal diameter spiral-wound element. The appropriate interfacing hardware for the specified element is furnished with the vessel.

The design adheres to the engineering standards of the Boiler and Pressure Vessel Code of the American Society of Mechanical Engineers (ASME) Code. ASME Code stamping and CE Marking are available options.

Operating limits

  • Design Pressure: 150 PSIG at 190°F (1.0 MPa at 88°C)
  • Minimum Operating Temperature: 20°F (-7°C)
  • Factory Test Pressure:
    • CE: 225 PSIG (1.6 MPa)
    • ASME: 165 PSIG (1.13 MPa)
  • Qualification Pressure: 900 PSI (6.2 MPa)
  • Maximum Permeate Pressure: 125 psi at 190°F (0.86 MPa at 88°C)
  • Operating pH Range: 3-10

Mechanical / hydraulic

Dimensions and Weights

The pressure vessel is available in several dash lengths, corresponding to overall length, span, and approximate weight:

DashLength L IN(MM)P IN(MM)S IN(MM)Approx Weight LB(KG)
60.1560.15 (1528)47 (1194)8 (207)92 (42)
100.15100.15 (2544)87 (2210)48 (1223)109 (49)
140.15140.15 (3560)127 (3226)80 (2032)127 (58)
180.15180.15 (4576)167 (4242)64 (1626)145 (66)
220.15220.15 (5592)207 (5258)78 (1981)162 (73)
260.15260.15 (6608)247 (6274)92 (2337)180 (82)
300.15300.15 (7624)287 (7290)106 (2692)197 (89)
340.15340.15 (8640)327 (8306)120 (3048)214 (97)

Standard Component Materials

  • SHELL: Filament Wound Epoxy/Glass composite - Head locking grooves integrally wound in place.
  • F/C Port: CF3M
  • F/C Port Seal: Ethylene Propylene
  • Bearing Plate: 6061-T6 Aluminium alloy - Hard anodized
  • Sealing Plate: Engineering Thermoplastic.
  • Permeate Port: Engineering Thermoplastic.
  • Port Nut: Engineering Thermoplastic.
  • Head Seal: Ethylene Propylene - O-Ring
  • Perm Port Seal: Ethylene Propylene - O-Ring
  • Quick Release Spiral Ring: 316 Stainless Steel.
  • Saddle: Engineering Thermoplastic.
  • Strap Assy.: 304 Stainless Steel-PVC Cushion.
  • Strap screw: 5/16-18 UNC, 18-8 Stainless Steel.
  • Adapter: Engineering Thermoplastic.
  • Adapter seal: Ethylene Propylene - O-Ring
  • PWT Seal: Ethylene Propylene - O-Ring
  • Thrust Cone: Engineering Thermoplastic.

Installation and Operating Precautions

  • Mount the shell on horizontal members at the specified span "S" using furnished compliant vessel supports.
  • Align and center side ports with the manifold header.
  • Use flexible type grooved-end pipe couplings (e.g., Victaulic® Style 77 or equal) at side ports, allowing a 0.125 inch gap between the port and piping.
  • Provide flexibility and support for piping manifolds to accommodate vessel expansion under pressure. For a length code –8 vessel, expansion can be ∆DIA = 0.015 in. (0.4mm) and ∆L = 0.2 in. (6mm).
  • Provide overpressure protection set at not more than 105% of design pressure.
  • Inspect end closures regularly; replace deteriorated components and correct causes of corrosion.
  • Lubricate seals sparingly with non-petroleum based lubricants (e.g., Parker Super O-lube®, Glycerin, or suitable silicone-based lubricants).
  • Do not work on any component until pressure is relieved from the vessel.
  • Do not make rigid piping connections or clamp the vessel in any way that restricts shell growth under pressure.
  • Do not hang piping manifolds from ports or use the vessel to support other components.
  • Do not tighten Permeate Port connections more than one turn past hand tight.
  • Do not operate the vessel without connecting both Permeate Ports internally to complete the set of elements, or otherwise plug ports internally so that external piping connections are not subjected to feed pressure.
  • Do not install a Spacer on the downstream end of the vessel.
  • Do not operate the vessel without the Thrust Cone installed downstream.
  • Do not pressurize the vessel until verifying that the Locking Ring is in place and fully seated.
  • Do not operate the vessel outside its specified pressure, temperature, or pH rating.
  • Do not tolerate leaks or allow end closures to be routinely wetted.

Ordering and Customization Options

  • Vessel Length Code: Available from -1 to -8.
  • Membrane Adapter: Adapters are supplied for specific membrane brands and models (e.g., eight-inch nominal diameter spiral-wound elements).
  • Certification: Options include ASME Stamped and National Board Registered, CE Marked Standard, Certified by Pentair Water, In compliance with ASME Sec X (not Code Stamped), Hydro testing at 1.1 or 1.5 times the design pressure.
  • Permeate Port Selection:
    • Size: 1”, 1.25”, 1.5” (Note: 1.25” & 1.5” BSPTF, 1.25” & 1.5” FNPT connections cannot be offered).
    • Type of Connection: FNPT, MNPT, BSPTM, BSPTF, IPS GROOVED.
    • Material of Construction: PET/Noryl, SS316L, Zeron 100.
    • Standard offering is 1.0” FNPT in PET/Noryl.
  • Strap Assembly: Standard SS304, Optional SS316, Optional SS316L.
  • Feed/Concentrate Port Selection:
    • Material of Construction: CF3M, Optional Duplex SS (CD3MN), Optional Super Duplex SS (CD3MWCuN).
    • Configuration: Standard - CF3M 1G5G, Optional – Multi ports (ports not available in 90º configurations).
  • Bearing Plate Material: Standard – 6061 T6 Aluminium, Optional – Stainless Steel 316L.
  • Adapter Kits: Available for Upstream and Downstream, with Port Size Codes: D (1½” GROOVED END), E (2” GROOVED END), F (2½” GROOVED END), G (3” GROOVED END).

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions of the official document. For contractual data and complete specifications, the OEM PDF revision used on the project must be consulted.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.