Datasheet summary
80H60
Engineering summary from PDF text extraction for 80H60. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: Codeline 80H60 Fiberglass RO Pressure Vessel
- Intended Use: Designed for continuous, long-term use as housing for reverse osmosis membrane elements to desalt typical brackish waters at pressures up to 600 psi.
- Element Compatibility: Accommodates any make of eight-inch nominal diameter spiral-wound element. Appropriate interfacing hardware is furnished with the vessel.
- Compliance: Designed in accordance with the engineering standards of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. ASME Code stamping and National Board Registration are available at an additional cost. CE Marking is also available.
Operating limits
- Design Pressure: 600 PSIG (4.1 MPa) at 190°F (88°C)
- Minimum Operating Temperature: 20°F (-7°C)
- Maximum Permeate Pressure: 125 psi (0.86 MPa) at 190°F (88°C)
- pH Range: 3-10
Mechanical / hydraulic
The vessel features a Filament Wound Epoxy/Glass composite shell with integrally wound head locking grooves. The end closure incorporates close-fitting, interlocking metal components.
Component Materials:
- Shell: Filament Wound Epoxy/Glass composite
- F/C Port: CF3M (standard)
- F/C Port Seal: Ethylene Propylene
- Bearing Plate: 6061-T6 Aluminium alloy - Hard anodized (standard)
- Sealing Plate: Engineering Thermoplastic (standard)
- Permeate Port: Engineering Thermoplastic (standard)
- Port Nut: Engineering Thermoplastic
- Head Seal: Ethylene Propylene - O-Ring
- Perm Port Seal: Ethylene Propylene - O-Ring
- Quick Release Spiral Ring: 316 Stainless Steel
- Saddle: Engineering Thermoplastic
- Strap Assembly: 304 Stainless Steel-PVC Cushion (standard)
- Strap Screw: 5/16-18 UNC, 18-8 Stainless Steel
- Adapter: Engineering Thermoplastic
- Adapter Seal: Ethylene Propylene - O-Ring
- PWT Seal: Ethylene Propylene - O-Ring
- Thrust Cone: Engineering Thermoplastic
Approximate Dimensions and Weights by Length Code:
- Dash -1: L 60.75 IN (1543 MM), P 47 IN (1194 MM), S 8X1 IN (222 MM), Approx Weight 114 LB (52 KG)
- Dash -2: L 100.75 IN (2559 MM), P 87 IN (2210 MM), S 48X1 IN (1238 MM), Approx Weight 136 LB (62 KG)
- Dash -3: L 140.75 IN (3575 MM), P 127 IN (3226 MM), S 80X1 IN (2032 MM), Approx Weight 158 LB (72 KG)
- Dash -4: L 180.75 IN (4591 MM), P 167 IN (4242 MM), S 64X2 IN (1626 MM), Approx Weight 180 LB (82 KG)
- Dash -5: L 220.75 IN (5607 MM), P 207 IN (5258 MM), S 78X2 IN (1981 MM), Approx Weight 202 LB (92 KG)
- Dash -6: L 260.75 IN (6623 MM), P 247 IN (6274 MM), S 92X2 IN (2337 MM), Approx Weight 224 LB (102 KG)
- Dash -7: L 300.75 IN (7639 MM), P 287 IN (7290 MM), S 106X2 IN (2692 MM), Approx Weight 246 LB (112 KG)
- Dash -8: L 340.75 IN (8655 MM), P 327 IN (8306 MM), S 120X2 IN (3048 MM), Approx Weight 268 LB (122 KG)
Expansion under pressure for a length code -8 vessel:
- Radial Expansion (∆DIA): 0.015 in. (0.4mm)
- Axial Expansion (∆L): 0.2 in. (6mm)
Factory Test Pressure
- CE Certified: 900 PSIG (6.20 MPa)
- ASME Certified: 660 PSIG (4.55 MPa)
- Qualification Pressure: 3600 PSI (24.8 MPa)
Ordering Options
The following features are configurable when ordering:
- Vessel Length Code: Available from -1 to -8.
- Membrane Brand and Model: To ensure suitable interfacing hardware is provided.
- Certifications: Options include ASME Stamped and National Board Registered, CE Marked Standard, Certified by Pentair Water, Compliance with ASME Section X (unstamped), and Hydro testing at 1.1 or 1.5 times the design pressure.
- Permeate Port Selection:
- Size: 1”, 1.25”, 1.5” (Standard offering is 1.0”).
- Type of Connection: FNPT (standard), MNPT, BSPTM, BSPTF, IPS GROOVED.
- Material of Construction: PET/Noryl (standard), SS316L, or Zeron 100. Options can be specified independently for the Serial Number End and Non Serial Number End.
- Strap Assembly: Standard SS304, or optional SS316 / SS316L.
- Feed/Concentrate Port Selection:
- Material of Construction: CF3M (standard), optional Duplex SS (CD3MN), or optional Super Duplex SS (CD3MWCuN).
- Configuration: Standard CF3M 1G5G, or optional Multi-port configurations.
- Bearing Plate Material: Standard 6061 T6 Aluminium, or optional Stainless Steel 316L.
- Adapter Kits: Available for upstream and downstream.
- Port Size Code: Options include D (1½” GROOVED END), E (2” GROOVED END), F (2½” GROOVED END), G (3” GROOVED END).
Precautions for Installation and Operation
- Mount the shell on horizontal members at span “S” using compliant vessel supports; shim saddles if required and tighten hold-down straps snugly.
- Align and center side ports with the manifold header, correcting any causes of misalignment.
- Use flexible grooved-end pipe couplings (e.g., Victaulic® Style 77) at side ports, allowing a 0.125 inch gap, and position piping for maximum flexibility.
- Provide flexibility in and support for piping manifolds to allow vessel growth under pressure without undue restraint.
- Install overpressure protection set at not more than 105% of the design pressure.
- Regularly inspect end closures, replacing deteriorated components and correcting corrosion.
- Lubricate seals sparingly with non-petroleum based lubricants (e.g., Parker Super O-lube®, Glycerin, or suitable silicone-based lubricants).
- Do not work on any component until verifying that pressure has been relieved from the vessel.
- Avoid rigid piping connections to ports or clamping the vessel in any way that resists the expansion of the fiberglass shell under pressure.
- Do not hang piping manifolds from ports or use the vessel to support other components.
- Do not overtighten Permeate Port connections (no more than one turn past hand tight).
- Ensure both Permeate Ports are connected internally to the full set of elements or otherwise plugged internally so external piping is not subjected to feed pressure.
- Do not install a Spacer on the downstream end of the vessel.
- Operate the vessel with the Thrust Cone installed downstream.
- Verify the Locking Ring is in place and fully seated before pressurizing the vessel.
- Do not operate the vessel at pressures or temperatures exceeding its rating.
- Do not operate the vessel with permeate pressure exceeding 125 psi at 190°F (0.86 MPa at 88°C).
- Do not tolerate leaks or allow end closures to be routinely wetted.
- Do not operate outside the pH range of 3-10.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions found in the official PDF. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.