Datasheet summary
80U30
Engineering summary from PDF text extraction for 80U30. Verify every value with the OEM datasheet.
Summary
Product identification
The CodeLine 80U30 Fiberglass RO Pressure Vessel is designed for continuous, long-term use as a housing for reverse osmosis membrane elements. It is intended for desalting typical brackish waters at pressures up to 300 psi. The vessel accommodates any make of eight-inch nominal diameter spiral-wound element, with appropriate interfacing hardware furnished.
The CodeLine 80U30 is designed in accordance with the engineering standards of the Boiler and Pressure Vessel Code of the American Society of Mechanical Engineers (ASME) Code.
Operating limits
- Design Pressure: 300 PSIG at 190°F (2.1 MPa at 88°C)
- Minimum Operating Temperature: 20°F (-7°C)
- Factory Test Pressure:
- CE: 450 PSIG (3.10 MPa)
- ASME: 330 PSIG (2.27 MPa)
- Qualification Pressure: 1800 PSI (12.4 MPa)
- Maximum Permeate Pressure: 125 psi at 190°F (0.86 MPa at 88PP0 PPC)
- pH Range: 3-10
Mechanical / Hydraulic (Materials)
The vessel components are constructed from the following materials:
- Shell: Filament Wound Epoxy/Glass composite with integrally wound head locking grooves.
- Feed/Concentrate (F/C) Port: CF3M (standard). Optional materials include Duplex SS (CD3MN) and Super Duplex SS (CD3MWCuN).
- F/C Port Seal: Ethylene Propylene
- Bearing Plate: 6061-T6 Aluminium alloy - Hard anodized (standard). Optional Stainless Steel 316L available.
- Sealing Plate: Engineering Thermoplastic (standard). An optional part is available for use with SS316L Bearing Plates.
- Spacer: Engineering Thermoplastic
- Permeate Port: Engineering Thermoplastic (standard). Optional materials include SS316L and Zeron 100.
- Port Nut: Engineering Thermoplastic
- Head Seal: Ethylene Propylene - O-Ring
- Permeate Port Seal: Ethylene Propylene - O-Ring
- Quick Release Spiral Ring: 316 Stainless Steel
- Saddle: Engineering Thermoplastic
- Strap Assembly: 304 Stainless Steel-PVC Cushion (standard). Optional SS316 and SS316L are available.
- Strap Screw: 5/16-18 UNC, 18-8 Stainless Steel
- Adapter: Engineering Thermoplastic
- Adapter Seal: Ethylene Propylene - O-Ring
- PWT Seal: Ethylene Propylene - O-Ring
- Thrust Cone: Engineering Thermoplastic
Mechanical / Hydraulic (Dimensions)
Dimensions and approximate weights for various vessel length codes:
| Dash Length | L IN(MM) | P IN(MM) | S IN(MM) | Approx Weight LB(KG) |
|---|---|---|---|---|
| -3 | 62.65 (1591) | 48 (1219) | 10X1 (254) | 123 (56) |
| -8 | 102.65 (2607) | 88 (2235) | 50X1 (1270) | 132 (60) |
| -6 | 142.65 (3623) | 128 (3251) | 80X1 (2032) | 139 (63) |
| -7 | 182.65 (4639) | 168 (4267) | 64X2 (1626) | 148 (67) |
| -1 | 222.65 (5655) | 208 (5283) | 78X2 (1981) | 157 (71) |
| -2 | 262.65 (6671) | 248 (6299) | 92X2 (2337) | 165 (75) |
| -4 | 302.65 (7687) | 288 (7315) | 106X2 (2692) | 174 (79) |
| -5 | 342.65 (8703) | 328 (8331) | 120X2 (3048) | 183 (83) |
Ordering Information
When ordering, specify the following:
- Vessel Length Code: -1 to -8.
- Membrane Brand and Model: Adapters for specific membrane brands and models are supplied.
- Certification Required:
- ASME Stamped and National Board Registered.
- CE Marked Standard.
- Certified by Pentair water.
- In compliance with ASME Sec X but not Code Stamped.
- Hydro testing at 1.1 times the design pressure.
- Hydro testing at 1.5 times the design pressure.
- Permeate Port Selection:
- Port End: Serial Number End or Non Serial Number End.
- Size: 1”, 1.25”, 1.5”. Note: Standard offering is 1.0” FNPT in PET/Noryl. 1.25” & 1.5” BSPTF, 1.25” & 1.5” FNPT connections are not available.
- Type of Connection: FNPT, MNPT, BSPTM, BSPTF, IPS GROOVED.
- Material of Construction: PET/Noryl, SS316L, Zeron 100.
- Strap Assembly: Standard SS304, Optional SS316, Optional SS316L.
- Feed/Concentrate Port Selection:
- Material of Construction: CF3M (standard), Optional Duplex SS (CD3MN), Optional Super Duplex SS (CD3MWCuN).
- Configuration: Standard - CF3M 1I5I, Optional – Multi ports (Ports not available in 90º configurations).
- Location: Serial number end or Opposite end.
- Bearing Plate Material: Standard – 6061 T6 Aluminium, Optional – Stainless Steel 316L.
- Adapter Kits: Upstream, Downstream.
- Port Size Code (for Adapter Kits): D (1½” GROOVED END), E (2” GROOVED END), F (2½” GROOVED END), G (3” GROOVED END), I (4” GROOVED END).
For detailed part numbers regarding Strap Assemblies, Permeate Port retainer rings and port nuts, Permeate Ports with offset distances, Bearing Plates, Sealing Plates, and Feed/Concentrate Ports and Seals, please refer to the official PDF datasheet. These tables provide specific part numbers based on material, size, and connection type.
Precautions
- DO read, understand and follow all instructions; failure to take every precaution will void warranty and may result in vessel failure.
- DO mount the shell on horizontal members at span “S” using compliant vessel supports furnished; shim saddles if required. Tighten hold down straps just snug.
- DO align and center side ports with the manifold header. Correct causes of misalignment in a row of vessels connected to the same header.
- DO use flexible type grooved-end pipe couplings, Victaulic® Style 77 or equal, at side ports; allow full, 0.125 inch gap between port and piping, and position piping to maximize flexibility of connection.
- DO provide flexibility in, and support for piping manifolds so that vessel can grow in length under pressure without undue restraint; provide additional flexible joints in large pipes leading to manifold header.
- DO provide overpressure protection for vessel set at not more than 105% of design pressure.
- DO inspect end closures regularly; replace components that have deteriorated and correct causes of corrosion.
- DO lubricate seals sparingly, using nonpetroleum based lubricants, i.e. Parker Super O-lube®, Glycerin or suitable silicone based lubricants.
- DO NOT work on any component until first verifying that pressure is relieved from vessel.
- DO NOT make rigid piping connections to ports or clamp vessel in any way that resists growth of fiberglass shell under pressure (∆DIA = 0.015 in. (0.4mm) and ∆L = 0.2 in. (6mm) for a length code –8 vessel).
- DO NOT hang piping manifolds from ports or use vessel in any way to support other components.
- DO NOT tighten Permeate Port connection more than one turn past hand tight.
- DO NOT operate vessel without connecting both Permeate Ports internally to complete set of elements or otherwise plug ports internally so that external piping connection is not subjected to feed pressure.
- DO NOT install Spacer on downstream end of vessel.
- DO NOT operate vessel without Thrust Cone installed downstream.
- DO NOT pressurize vessel until double-checking to verify that the Locking Ring is in place and fully seated.
- DO NOT operate vessel at pressure and temperature in excess of its rating.
- DO NOT operate vessel with permeate pressure in excess of 125 psi at 190°F (0.86 MPa at 88PP0 PPC).
- DO NOT tolerate leaks or allow end closures to be routinely wetted in any way.
- DO NOT operate outside the pH range 3-10.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original document. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.