Back to Wila Heat Exchangers
Wila logo

Datasheet summary

THEX 60

Engineering summary from PDF text extraction for THEX 60. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Line: THEX
  • Type: Tubular Heat Exchanger
  • Design Pressure: High Pressure - 60 BAR
  • Manufacturer: Wila A/S

Applications

  • Food and beverage industry
  • CIP units
  • Microbial reduction to ensure product safety and extend shelf life
  • Heating or cooling products prior to filling, drying, concentration, or other processes

Materials

  • Material: EN.1.4404 (AISI 316L) stainless steel
  • Surface Finish: Sanitary
  • Outer surface roughness: ≤ 1.6µm
  • Internal tube side surface roughness: ≤ 0.8µm
  • Fluid Compatibility: All fluid media must be compatible with EN.1.4404 (AISI 316L) Stainless Steel.

Operating Limits

  • Maximum Product Side Pressure: 60 barg / 85°C (for THEX-.5, THEX-01, THEX-03 series)
    • For THEX-02 series: 60 barg / 85°C
  • Maximum Shell Side Pressure and Temperature:
    • 0.5m² and 1 m²: 10 bar[g] / 185°C
    • 2 m²: 8 bar[g] / 176°C
    • 3 m²: 6 bar[g] / 165°C
    • For fluids other than steam, consult "Heat exchangers – pressure and temperature relations" document.

Design and Construction

  • Design: Two Pressure chambers in a combined housing.
    • Tube side: Inner chamber, including all tubes.
    • Shell side: Outer pressure chamber, between the tube bundle and the exchanger's outer shell.
  • Configuration: Eccentric product side reducer.
  • Shell Diameter: Ø133 mm (for models listed)

Connections

  • Tube side (P1 and P2) connection sizes:
    • Ø133 shell size: DN100 - DN80 (in accordance with DIN 32676-A)
    • Ø133 shell size: 4” (Ø101.6) - 3” (Ø76.1) (in accordance with ISO 2852-2)
  • Shell side (S1 and S2) connection sizes:
    • DN50 – DN40 (in accordance with DIN 32676-A)
    • 2” (Ø51) – 1.5” (Ø38) (in accordance with ISO 2852-2)
  • Other connection types and sizes: Available upon request.
  • Recommendations: SSH clamping rings (or similar) are recommended. For steam, the outlet should be at the lowest point; for liquids, at the highest point.

Product Variants and Specifications

The ordering code follows the pattern THEX-xx-133-yyy-zz:

  • xx: Heat transfer surface area in m² (.5, 01, 02, 03)
  • 133: Shell diameter in mm
  • yyy: Tube side connection size
  • zz: Shell side connection size

THEX-.5-133-60 Series (0.5 m²)

  • Maximum Pressure / Maximum Temperature: 60 barg / 85°C
  • Shell Side Limits: 10 bar[g] / 185°C
  • Volume: 4.5 liters (product side) / 1 liter (shell side)
  • Dry Weight: 11 kg
  • Tube bank: 61 pc Ø12x1mm

Specific models include variations in tube and shell side connections (e.g., THEX-.5-133-100-51, THEX-.5-133-076-38).

THEX-01-133-60 Series (1 m²)

  • Maximum Pressure / Maximum Temperature: 60 barg / 85°C
  • Shell Side Limits: 10 bar[g] / 185°C
  • Volume: 6 liters (product side) / 2.5 liters (shell side)
  • Dry Weight: 19 kg
  • Tube bank: 61 pc Ø12x1mm

Specific models include variations in tube and shell side connections (e.g., THEX-01-133-100-51, THEX-01-133-076-38).

THEX-02-133-60 Series (2 m²)

  • Maximum Pressure / Maximum Temperature: 60 barg / 85°C
  • Shell Side Limits: 8 bar[g] / 176°C
  • Volume: 8.5 liters (product side) / 5 liters (shell side)
  • Dry Weight: 34 kg
  • Tube bank: 61 pc Ø12x1mm

Specific models include variations in tube and shell side connections (e.g., THEX-02-133-100-51, THEX-02-133-076-38).

THEX-03-133-60 Series (3 m²)

  • Maximum Pressure / Maximum Temperature: 60 barg / 85°C
  • Shell Side Limits: 6 bar[g] / 165°C
  • Volume: 10 liters (product side) / 7.5 liters (shell side)
  • Dry Weight: 48 kg
  • Tube bank: 61 pc Ø12x1mm

Specific models include variations in tube and shell side connections (e.g., THEX-03-133-100-51, THEX-03-133-076-38).

Regulations and Directives

The heat exchanger is designed and manufactured in accordance with:

  • European Commission regulation No. 2023/2006 (Good Manufacturing Practices)
  • European Parliament directive No. EN 1935/2004 (Food Contact Materials)
  • European Parliament directive No. EN 1907/2006 (Chemical Restrictions (REACH))
  • PED - Article 4.3 (SEP) in the European Parliament directive No. 2014/68/EU (Pressure Equipment Directive).
  • Designed for fluid group 2 (non-dangerous fluids).

Documentation

  • Customer drawing with description and design data table
  • Declaration of conformity
  • Pressure test certificate
  • User Manual

Supplemental Documentation (upon request):

  • 3.1 material certificates according to EN 10204
  • Weld-logs with associated welding certificates according to DS/EN ISO 9601-1

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.