Datasheet summary
THEXA 60
Engineering summary from PDF text extraction for THEXA 60. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: THEXA
- Type: Tubular Heat Exchanger
- Pressure Rating: HIGH PRESSURE - 60 BAR
The THEXA heat exchanger consists of two pressure chambers: the "Tube side" or "Product side" (inside tubes) and the "Shell side" or "Service side" (outside tubes, inside shell). It is designed for fluid-to-fluid heat transfer (cooling or heating).
Materials
- Construction Material: EN.1.4404 (AISI 316L) stainless steel
- Surface Finish:
- Tube side: ≤ 0.8 µm (Ra)
- Shell side: ≤ 1.6 µm (Ra)
- Compatibility: All fluid media must be compatible with EN.1.4404 (AISI 316L) Stainless Steel.
Operating Limits
- Maximum Product Side Pressure: 60 bar[g] (870 PSI)
- Service Side Limits (Steam):
- 0.5 m² and 1 m²: 10 bar[g] / 185°C
- 2 m²: 8 bar[g] / 176°C
- 3 m²: 6 bar[g] / 165°C
- 4 m² and 6 m²: 3 bar[g] / 144°C
- 8 m²: 2.3 bar[g] / 136°C
- For other fluids, refer to "Heat exchangers – pressure and temperature relations" document.
Product Specifics
THEXA-xx-133-60
- Shell Diameter: Ø133 mm
- Pressure Design: Based on Ø133x4 shell.
Connections
- Tube Side (P1/P2):
- Shell size Ø133 mm: DN100 - DN80 (DIN 32676-A) or 4” (Ø101.6) - 3” (Ø76.1) (ISO 2852-2)
- Shell Side (S1/S2):
- DN50 – DN40 (DIN 32676-A) or 2” (Ø51) – 1.5” (Ø38) (ISO 2852-2)
- Other connection types and sizes are available.
Model Overview (Examples)
THEXA-.5-133-60 (0.5 m² Heat Transfer Surface Area)
- Maximum Pressure/Temperature: 40 barg / 85°C
- Service Side Limits (Steam): 10 bar[g] / 185°C
- Volume (Product Side): 1 liter
- Volume (Shell Side): 4.5 liters
- Dry Weight: 9 kg
- Tube Bank: 61 tubes of Ø12x1mm
Table Data (Example for THEXA-.5-133-100-51):
- Stock number: W-035512
- P1/P2: DN100
- A: Ø133
- S1/S2: Ø51
- B: 190
- C: 130
- D: 558
THEXA-01-133-60 (1 m² Heat Transfer Surface Area)
- Maximum Pressure/Temperature: 40 barg / 85°C
- Service Side Limits (Steam): 10 bar[g] / 185°C
- Volume (Product Side): 2.5 liters
- Volume (Shell Side): 6 liters
- Dry Weight: 15 kg
- Tube Bank: 61 tubes of Ø12x1mm
Table Data (Example for THEXA-01-133-100-51):
- Stock number: W-035532
- P1/P2: DN100
- A: Ø133
- S1/S2: Ø51
- B: 190
- C: 380
- D: 808
THEXA-02-133-60 (2 m² Heat Transfer Surface Area)
- Maximum Pressure/Temperature: 40 barg / 85°C
- Service Side Limits (Steam): 8 bar[g] / 176°C
- Volume (Product Side): 5 liters
- Volume (Shell Side): 8.5 liters
- Dry Weight: 26 kg
- Tube Bank: 61 tubes of Ø12x1mm
Table Data (Example for THEXA-02-133-100-51):
- Stock number: W-035552
- P1/P2: DN100
- A: Ø133
- S1/S2: Ø51
- B: 190
- C: 870
- D: 1268
THEXA-03-133-60 (3 m² Heat Transfer Surface Area)
- Maximum Pressure/Temperature: 40 barg / 85°C
- Service Side Limits (Steam): 6 bar[g] / 165°C
- Volume (Product Side): 7.5 liters
- Volume (Shell Side): 10 liters
- Dry Weight: 38 kg
- Tube Bank: 61 tubes of Ø12x1mm
Table Data (Example for THEXA-03-133-100-51):
- Stock number: W-035572
- P1/P2: DN100
- A: Ø133
- S1/S2: Ø51
- B: 190
- C: 1360
- D: 1788
Regulations and Directives
The heat exchanger is designed and manufactured in accordance with:
- European Commission regulation No. 2023/2006 (Good Manufacturing Practices)
- European Parliament directive No. EN 1935/2004 (Food Contact Materials)
- European Parliament directive No. EN 1907/2006 (Chemical Restrictions (REACH))
- PED - Article 4.3 (SEP) in the European Parliament directive No. 2014/68/EU (Pressure Equipment Directive) - only for fluid group 2 (non-dangerous fluids)
- 3-A Sanitary Standards 00-01 / 12-08
Documentation
The following documents are typically provided:
- Customer drawing with description and design data table
- Declaration of conformity
- Pressure test certificate
- User Manual
Optional supplements: 5. 3.1 material certificates according to EN 10204 6. Weld-logs with associated welding certificates according to DS/EN ISO 9601-1.
Disclaimer
This summary is extracted from a datasheet and may not include all figures, footnotes, or revisions. Contractual data must match the specific revision of the OEM PDF used for the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.