Datasheet summary
TLC 60
Engineering summary from PDF text extraction for TLC 60. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Type: Tubular Liquid Cooler
- Series: TLC
- Pressure Rating: High Pressure - 60 BAR (870 PSI)
- Material: EN.1.4404 (AISI 316L) stainless steel with a sanitary surface finish
Applications
Tubular Liquid Coolers are commonly used in the food and beverage industry, including applications such as CIP units. They are utilized to reduce or eliminate microbials for product safety and shelf-life extension, and for heating or cooling products prior to various processes like filling, drying, or concentration.
Operating Limits
- Maximum Product Side Pressure: 60 barg / 85°C
- Maximum Service Side Pressure: 16 barg / 95°C
Materials and Surface Finish
- Material: EN.1.4404 (AISI 316L) stainless steel
- Tube Side Surface Roughness: ≤ 0.8 µm
- Shell Side Surface Roughness: ≤ 1.6 µm
- Fluid Compatibility: All fluid media must be compatible with EN.1.4404 (AISI 316L) Stainless Steel.
Design and Construction
- Design Basis: Ø133x4 shell for the 60 BAR design.
- Structure: Two pressure chambers (Tube side/Product side and Shell side/Service side) in a combined housing.
- Tubes: Tube bank consists of 61 tubes of Ø12x1mm.
- Fluid Group: Designed for fluid group 2 (non-dangerous fluids) as per PED Directive 2014/68/EU.
Connections
- Tube Side (P1 and P2) Connections:
- For Shell size Ø133: DN100, DN80, DN65 (in accordance with DIN 32676-A)
- For Shell size Ø133: 4” (Ø101.6), 3” (Ø76.1), 2.5” (Ø63.5) (In accordance with ISO 2852-2)
- Shell Side (S1 and S2) Connections:
- DN20, DN25, DN40, DN50, DN65 (in accordance with DIN 32676-A)
- 3/4” (Ø20), 1” (Ø25), 1.5” (Ø38), 2” (Ø51), 2.5” (Ø63.5) (in accordance with ISO 2852-2)
- Note: Other connection types and sizes are available upon request.
Shell Side Workflow Limits
- 0.5 m²: Recommended maximum 3 m³/h
- 1 m²: Recommended maximum 3 m³/h
- 2 m²: Recommended maximum 7 m³/h
- 3 m²: Recommended maximum 12 m³/h
Regulations and Directives
The heat exchanger is designed and manufactured in accordance with:
- European Commission regulation No. 2023/2006 (Good Manufacturing Practices)
- European Parliament directive No. EN 1935/2004 (Food Contact Materials)
- European Parliament directive No. EN 1907/2006 (Chemical Restrictions (REACH))
- PED - Article 4.3 (SEP) in the European Parliament directive No. 2014/68/EU (Pressure Equipment Directive)
Documentation
- Customer drawing with description and design data table
- Declaration of conformity
- Pressure test certificate
- User Manual
- Optional: 3.1 material certificates (EN 10204), Weld-logs, and welding certificates (DS/EN ISO 9601-1).
Model Naming Convention
-
TLC-xx-133-60:
TLC: Tubular Liquid Coolersxx: Heat transfer surface area in m² (.5, 01, 02, 03)133: Heat exchanger shell diameter in mm (Ø133)60: Design pressure up to 60 bar
-
TLC-xx-xxx-yyy-zz:
xx,xxx: As aboveyyy: Tube side connection codezz: Shell side connection code
Specific Model Data
Detailed specifications including stock numbers, dimensions (A, B, C, D), and tube bank configurations for models TLC-.5-133-60, TLC-01-133-60, TLC-02-133-60, and TLC-03-133-60 are provided in tabular format. See the official PDF for exact tabulated values.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.