Back to Wila Heat Exchangers
Wila logo

Datasheet summary

TSH 40

Engineering summary from PDF text extraction for TSH 40. Verify every value with the OEM datasheet.

Summary

Product Identification

The product is a Tubular Steam Heater, type 'TSH', designed for medium pressure applications up to 40 bar.

Operating Limits

The heat exchanger is designed for steam to fluid heat transfer. The maximum product side pressure is 40 barg. The maximum service (shell) side pressure and temperature limits vary by heat exchanger size:

  • 1 m²: 10 bar[g] / 185°C
  • 2 m²: 8 bar[g] / 176°C
  • 3 m²: 6 bar[g] / 165°C
  • 4 m² & 6 m²: 3 bar[g] / 144°C
  • 8 m²: 2.3 bar[g] / 136°C

Feed Water

The heat exchanger is suitable for food stuff fluids, such as dairy products and juices, on the tube side. All fluid media must be compatible with EN.1.4404 (AISI 316L) Stainless Steel.

Product Water

  • Material: EN.1.4404 (AISI 316L) stainless steel
  • Outside surface roughness: ≤ 1,6µm
  • Internal tube side surface roughness: ≤ 0,8µm

Electrical

Not applicable.

Mechanical / Hydraulic

The heat exchanger consists of two pressure chambers:

  • Tube side: Contains the tubes within the tube bundle.
  • Shell side: Contains the outside of the tube bundle and the inside of the exchanger's outer shell.

The design is based on either a Ø129x2mm shell or a Ø209x3mm shell.

Connections

  • Tube side (P1 and P2) connections:
    • Ø129mm shell: DN125, DN100, DN80, DN65 (in accordance with DIN 32676-A); Ø101.6, Ø76.1, Ø63.5 (in accordance with ISO 2852-2).
    • Ø209mm shell: DN150, DN125, DN100 (in accordance with DIN 32676-A); Ø101.6 (in accordance with ISO 2852-2).
  • Shell side (S1 and S2) connections:
    • For both Ø129 and Ø209mm shells: DN80, DN65, DN50, DN40, DN25 (in accordance with DIN 32676-A); Ø76.1, Ø63.5, Ø51, Ø38, Ø25 (in accordance with ISO 2852-2).
    • Also available with DIN 2633 / EN 1092 Type 11 connections.

Other connection types and sizes are available upon request.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or revisions. Contractual data must be verified against the official OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.