Product identification

  • Product line: Proline Promag D 10 electromagnetic flowmeter
  • Headline: Highly cost-effective wafer flowmeter with easy-to-use operation concept.
  • Application: Designed for all basic water applications where space is at a minimum. Optimized for limited space and plastic pipe installations.
  • Model: Proline Promag D 10 / 5DBB

Operating limits

  • Max. process pressure: PN 16, Class 150, 10K
  • Medium temperature range (Liner material polyamide): 0 to +60°C (+32 to +140°F)
  • Ambient temperature range: -40 to 60°C (-40 to 140°F)

Feed water

  • Wetted materials:
    • Liner material: Polyamide
    • Electrodes: 1.4435 (316L)

Product water

  • Measured variables: Volume flow, mass flow

Performance

  • Max. measurement error (Volume flow, standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
  • Measuring range: 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)

Electrical

  • Outputs: 4-20 mA HART (active/passive), Pulse/frequency/switch output, Modbus RS485, 4-20 mA
  • Digital communication: HART, MODBUS RS485
  • Power supply: DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area)

Mechanical / hydraulic

  • Nominal diameter range: DN 25 to 100 (1 to 4")
  • Sensor housing material: DN 25 to 100 (1 to 12"): AlSi10Mg, coated
  • Transmitter housing material: Polycarbonat; AlSi10Mg, coated
  • Degree of protection:
    • Compact version: IP66/67, type 4X enclosure
    • Sensor remote version (standard): IP66/67, type 4X enclosure
  • Display/Operation: LCD display with touch & auto rotate

Features

  • Easy, fast centering of the sensor – innovative housing construction
  • Energy-saving flow measurement – no pressure loss due to cross section constriction
  • Maintenance-free – no moving parts
  • Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
  • Simple, time-saving commissioning – guided parameterization
  • Integrated verification – Heartbeat Technology
  • Short face-to-face length and low weight
  • Integrated ground disks made of stainless steel
  • International drinking water approvals

Approvals and certificates

  • Hazardous area approvals: CSA, GP
  • Product safety:
  • Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with ISO 9001:2015 requirements.
  • Hygienic approvals and certificates: