Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Proline-Promag E 100

PDF datasheet mirror for Proline-Promag E 100 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

  • Product line: Proline Promag E 100
  • Model: Proline Promag E 100 / 5E1B
  • Headline: The economical flowmeter with an ultra-compact transmitter.
  • Description: Proven sensor for economical measurement of conductive liquids, suitable for basic applications in the chemical and process industry. Ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration. Heartbeat Technology for compliance and process safety.

Field of application

  • Basic applications in the chemical and process industry.
  • Preferred choice for skid builders, equipment manufacturers, and system integrators.

Features and specifications

Sensor features

  • Cost-effective sensor – ideal solution for basic requirements.
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction.
  • Maintenance-free – no moving parts.
  • Nominal diameter: max. DN 600 (24").
  • Ex approvals for Zone 2.
  • Liner made of PTFE.

Transmitter features

  • Space-saving transmitter – full functionality on the smallest footprint.
  • Time-saving local operation without additional software and hardware – integrated web server.
  • Integrated verification – Heartbeat Technology.
  • Robust, ultra-compact transmitter housing.
  • Local display available (4-line backlit display).
  • Configuration via web browser and operating tools possible.

Wetted materials

  • Liner: PTFE
  • Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Performance

  • Max. measurement error (Volume flow, standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
  • Max. measurement error (Volume flow, option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
  • Measuring range: 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
  • Measured variables: Volume flow, conductivity, mass flow

Operating limits

  • Nominal diameter range: DN 15 to 600 (½ to 24")
  • Max. process pressure: PN 40, Class 150, 20K
  • Medium temperature range: –10 to +110 °C (+14 to +230 °F)
  • Ambient temperature range: –10 to +60 °C (+14 to +140 °F)

Mechanical / hydraulic

  • Sensor housing material:
    • DN 15 to 300 (½ to 12"): AlSi10Mg, coated
    • DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
  • Transmitter housing material: AlSi10Mg, coated
  • Degree of protection: IP67, type 4X enclosure

Electrical

  • Outputs:
    • 4–20 mA HART (active)
    • Pulse/frequency/switch output (passive)
  • Inputs: None
  • Digital communication: HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
  • Power supply: DC 20 to 30 V

Approvals and certificates

  • Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, EAC
  • Product safety: CE, C-Tick
  • Metrological approvals: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025); Heartbeat Technology complies with ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • Pressure approvals: PED
  • Material certificates: 3.1 material

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.