Datasheet summary
Proline-Promag E 100
PDF datasheet mirror for Proline-Promag E 100 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product line: Proline Promag E 100
- Model: Proline Promag E 100 / 5E1B
- Headline: The economical flowmeter with an ultra-compact transmitter.
- Description: Proven sensor for economical measurement of conductive liquids, suitable for basic applications in the chemical and process industry. Ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration. Heartbeat Technology for compliance and process safety.
Field of application
- Basic applications in the chemical and process industry.
- Preferred choice for skid builders, equipment manufacturers, and system integrators.
Features and specifications
Sensor features
- Cost-effective sensor – ideal solution for basic requirements.
- Energy-saving flow measurement – no pressure loss due to cross-section constriction.
- Maintenance-free – no moving parts.
- Nominal diameter: max. DN 600 (24").
- Ex approvals for Zone 2.
- Liner made of PTFE.
Transmitter features
- Space-saving transmitter – full functionality on the smallest footprint.
- Time-saving local operation without additional software and hardware – integrated web server.
- Integrated verification – Heartbeat Technology.
- Robust, ultra-compact transmitter housing.
- Local display available (4-line backlit display).
- Configuration via web browser and operating tools possible.
Wetted materials
- Liner: PTFE
- Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Performance
- Max. measurement error (Volume flow, standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
- Max. measurement error (Volume flow, option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
- Measuring range: 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
- Measured variables: Volume flow, conductivity, mass flow
Operating limits
- Nominal diameter range: DN 15 to 600 (½ to 24")
- Max. process pressure: PN 40, Class 150, 20K
- Medium temperature range: –10 to +110 °C (+14 to +230 °F)
- Ambient temperature range: –10 to +60 °C (+14 to +140 °F)
Mechanical / hydraulic
- Sensor housing material:
- DN 15 to 300 (½ to 12"): AlSi10Mg, coated
- DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
- Transmitter housing material: AlSi10Mg, coated
- Degree of protection: IP67, type 4X enclosure
Electrical
- Outputs:
- 4–20 mA HART (active)
- Pulse/frequency/switch output (passive)
- Inputs: None
- Digital communication: HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
- Power supply: DC 20 to 30 V
Approvals and certificates
- Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, EAC
- Product safety: CE, C-Tick
- Metrological approvals: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025); Heartbeat Technology complies with ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
- Pressure approvals: PED
- Material certificates: 3.1 material
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.