Datasheet summary
Proline-Promag H 10
PDF datasheet mirror for Proline-Promag H 10 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product Identification
- Product line: Proline Promag H 10 electromagnetic flowmeter
- Headline: Flowmeter for basic hygienic applications with easy-to-use operation concept.
- Field of application: Hygienic applications in the food and beverage and life sciences industries.
Features and Specifications
Sensor
- Measuring principle: Electromagnetic
- Nominal diameter range: DN 2 to 150 (¹⁄₁₂ to 6")
- Wetted materials:
- Liner: PFA
- Electrodes: 1.4435 (316L); Alloy C22
- Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
- Seals: aseptic molded seal (EPDM, FKM, silicone)
- Sensor housing material: 1.4301 (304), corrosion resistant
- Housing approvals: 3-A, EHEDG
- Cleanability: CIP-/SIP-cleanable
Transmitter
- Transmitter housing material: AlSi10Mg, coated
- Degree of protection: IP66/67, type 4X enclosure
- Display/Operation: 2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible.
- System integration: HART, Modbus RS485, IO-Link
- Outputs: 4-20 mA HART (active/passive), Pulse/frequency/switch output; Modbus RS485, 4-20 mA
Operating Limits
- Max. measurement error (Volume flow, standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
- Measuring range (Volume flow): 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
- Max. process pressure: PN 40, Class 150, 20K
- Medium temperature range: –20 to +150 °C (–4 to +302 °F)
- Ambient temperature range: –40 to +60 °C (–40 to +140 °F)
Electrical
- Power supply:
- DC 24 V
- AC 100 to 230 V
- AC 100 to 230 V / DC 24 V (non-hazardous area)
Approvals and Certificates
- Hazardous area approvals: CSA, GP, KC
- Metrological approvals: Calibration accredited to ISO/IEC 17025; Heartbeat Technology complies with ISO 9001:2015 Section 7.1.5.2 a (TÜV SÜD).
- Pressure approvals: PED, CRN
- Material certificates: 3.1 material
- Hygienic approvals: EHEDG, 3-A, liner and seals acc. to FDA, cGMP
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.