Datasheet summary
Proline-Promag P 10
PDF datasheet mirror for Proline-Promag P 10 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product line: Proline Promag P 10
- Type: Electromagnetic flowmeter
- Model: Proline Promag P 10 / 5PBB
- Headline: Flowmeter for basic process applications with easy-to-use operation concept.
- Application: Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Operating limits
- Max. measurement error (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
- Max. measurement error (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
- Measuring range: 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
- Max. process pressure: PN 40, Class 300, 20K
Feed water
- Medium temperature range (Liner PFA): –20 to +150 °C (–4 to +302 °F)
- Medium temperature range (Liner PTFE): –40 to +130 °C (–40 to +266 °F)
- Ambient temperature range (Flange carbon steel): –10 to +60 °C (+14 to +140 °F)
- Ambient temperature range (Flange stainless steel): –40 to +60 °C (–40 to +140 °F)
Product water
- Drinking water approvals: ACS; NSF61, WRAS
Electrical
- Power supply: DC 24 V; AC 100 to 230 V; AC 100 to 230 V / DC 24 V (non-hazardous area)
- Outputs: 4-20 mA HART (active/passive), Pulse/frequency/switch output; Modbus RS485, 4-20 mA
- Digital communication: HART, MODBUS RS485
Mechanical / hydraulic
- Nominal diameter range: DN 15 to 600 (½ to 24")
- Wetted materials:
- Liner: PFA; PTFE
- Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
- Sensor housing material:
- DN 15 to 300 (½ to 12"): AlSi10Mg, coated
- DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
- Transmitter housing material: AlSi10Mg, coated
- Degree of protection: Standard: IP66/67, Type 4X enclosure
- Display/Operation: 2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
Approvals and Certificates
- Hazardous area approvals: ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, IND Ex, KC, JPN, UK Ex
- Metrological approvals: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025); Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
- Pressure approvals: PED, CRN
- Material certificates: 3.1 material
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.