Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Proline-Promag P 200

PDF datasheet mirror for Proline-Promag P 200 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

Product: Proline Promag P 200 / 5P2B Type: Electromagnetic flowmeter

Field of application

Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Suitable for hazardous areas with intrinsically safe (Ex ia) design.

Benefits

  • Versatile applications with a wide variety of wetted materials.
  • Energy-saving flow measurement with no pressure loss due to cross-section constriction.
  • Maintenance-free operation due to no moving parts.
  • Convenient device wiring with a separate connection compartment.
  • Safe operation without needing to open the device, thanks to a display with touch control and background lighting.
  • Integrated verification via Heartbeat Technology for continuous process safety.

Operating limits

  • Max. process pressure: PN 40, Class 300, 20K
  • Medium temperature range:
    • Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    • Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
  • Ambient temperature range:
    • Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    • Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

Feed water

  • Measuring principle: Electromagnetic
  • Measured variables: Volume flow, mass flow
  • Measuring range: 4 dm³/min to 1100 m³/h (1 to 4850 gal/min)
  • Max. measurement error (Volume flow): ±0.5 % o.r. ± 2 mm/s (0.08 in/s)

Product water

  • Nominal diameter range: DN 15 to 200 (½ to 8")

Electrical

  • Power supply: DC 18 to 35 V (for 4–20 mA HART with/without pulse/frequency/switch output)
  • Outputs:
    • 4–20 mA HART (passive)
    • Pulse/frequency/switch output (passive)
  • Inputs: None
  • Digital communication: HART, PROFIBUS PA, FOUNDATION Fieldbus

Mechanical / hydraulic

  • Wetted materials:
    • Liner: PFA; PTFE
    • Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
  • Sensor housing material: AlSi10Mg, coated
  • Transmitter housing material: AlSi10Mg, coated
  • Degree of protection: IP66/67, type 4X enclosure
  • Display/Operation: 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible. Remote display available.

Approvals and Certificates

  • Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, JPN, UK Ex
  • Product safety: CE, C-Tick
  • Functional safety: IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
  • Metrological approvals: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation).
  • Pressure approvals: CRN, PED
  • Material certificates: 3.1 material
  • Hygienic approvals: Drinking water approvals: ACS, NSF 61

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.