Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Proline-Promag P 500

PDF datasheet mirror for Proline-Promag P 500 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

  • Product name: Proline Promag P 500
  • Product headline: High-temperature flowmeter for process applications as remote version with up to 4 I/Os.
  • Model: 5P5B

Field of application

Dedicated to chemical and process applications with corrosive liquids and highest medium temperatures.

Features and specifications

Sensor features

  • Wide variety of wetted materials.
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction.
  • Maintenance-free – no moving parts.
  • Nominal diameter: max. DN 600 (24").
  • Liner made of PTFE or PFA.

Transmitter features

  • Full access to process and diagnostic information.
  • Numerous, freely combinable I/Os and fieldbuses.
  • Freely configurable I/O functionality.
  • Integrated verification – Heartbeat Technology.
  • Remote version with up to 4 I/Os.
  • Backlit display with touch control and WLAN access.
  • Standard cable between sensor and transmitter.

Operating limits

  • Max. process pressure: PN 40, Class 300, 20K

Feed water

Medium temperature range

  • Liner material PFA: –20 to +150 °C (–4 to +302 °F)
  • Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
  • Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

Ambient temperature range

  • Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
  • Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

Product water

Measured variables

  • Volume flow
  • Conductivity
  • Mass flow

Max. measurement error

  • Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
  • Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

Measuring range

  • 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)

Electrical

  • Power supply: DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area)
  • Outputs: 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output
  • Inputs: Status input, 4-20 mA input
  • Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Mechanical / hydraulic

  • Nominal diameter range: DN 15 to 600 (½ to 24")
  • Wetted materials:
    • Liner: PFA; PTFE
    • Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium; Duplex 1.4462 (UNS S31803)
  • Sensor housing material:
    • DN 15 to 300 (½ to 12"): AlSi10Mg, coated
    • DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
  • Sensor connection housing (standard): AlSi10Mg, coated
  • Sensor connection housing (option): 1.4409 (CF3M) similar to 316L
  • Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
  • Degree of protection:
    • Sensor remote version (standard): IP66/67, type 4X enclosure
    • Transmitter remote version: IP66/67, Type 4X enclosure
  • Display/Operation: 4-line backlit display with touch control. Configuration via local display and operating tools possible.

Approvals and certifications

  • Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
  • Product safety: CE, C-tick, EAC marking
  • Functional safety: According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
  • Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation).
  • Marine approvals and certificates: LR approval, DNV approval, ABS approval, BV approval
  • Pressure approvals and certificates: PED, CRN
  • Material certificates: 3.1 material
  • Hygienic approvals and certificates: ACS, NSF 61, WRAS