Datasheet summary
Proline-Promag W 10
PDF datasheet mirror for Proline-Promag W 10 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product name: Proline Promag W 10
- Product type: Electromagnetic flowmeter
- Headline: Flowmeter for basic water and wastewater applications with easy-to-use operation concept.
- Field of application: Water and wastewater, raw water intake. International drinking water approvals (e.g., ACS, KTW/W270, NSF 61, WRAS BS 6920).
- Measurement principle: Electromagnetic
- Measured variables: Volume flow, conductivity, mass flow
Operating limits
- Max. measurement error (Volume flow, standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
- Measuring range: 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1665 Mgal/d)
- Max. process pressure: PN 40, Class 300, 20K
- Ambient temperature range: -40 to +60 °C (-40 to +140 °F)
Feed water (Medium)
- Liquids: Suitable for liquids.
- Medium temperature range:
- Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
- Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
- Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Product water (Wetted materials)
- Liner material:
- Hard rubber: 0 to +80 °C (+32 to +176 °F)
- Polyurethane: –20 to +50 °C (–4 to +122 °F)
- PTFE: –20 to +90 °C (–4 to +160 °F)
- Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Electrical
- Outputs: 4-20 mA HART (active/passive), Pulse/frequency/switch output, Modbus RS485, 4-20 mA
- Digital communication: HART, MODBUS RS485
- Power supply:
- DC 24 V
- AC 100 to 230 V
- AC 100 to 230 V / DC 24 V (non-hazardous area)
- Hazardous area approvals: CSA, GP, KC
Mechanical / hydraulic
- Nominal diameter range: DN 25 to 3000 (1 to 120")
- Sensor housing material:
- DN 25 to 300 (1 to 12"): AlSi10Mg, coated
- DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish
- Transmitter housing material: Polycarbonat; AlSi10Mg, coated
- Degree of protection:
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version (standard): IP66/67, type 4X enclosure
- Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3
- Display/Operation: LCD display with touch & auto rotate
- Installation length: DVGW/ISO conform
- Corrosion protection: EN ISO 12944 for underground or underwater installation.
- Process connections: Fixed or lap-joint
- Pressure approvals and certificates: CRN, PED
- Material certificates: 3.1 material
Features and Technologies
- Operation: Easy-to-use operation concept, operation with mobile devices and SmartBlue app or display with touch screen.
- Commissioning: Simple, time-saving commissioning with guided parameterization.
- Verification: Integrated verification with Heartbeat Technology.
- Accuracy: Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss.
- Approvals: International drinking water approvals.
- Calibration: Performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with ISO 9001:2015 requirements for measurement traceability.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.