
Datasheet summary
Proline Promass A 100
PDF datasheet mirror for Proline Promass A 100 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product line: Proline Promass A 100
- Type: Coriolis flowmeter
- Headline: The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.
Field of application
Promass A is designed for highly accurate measurement of small quantities of liquids and gases, suitable for high and low pressure applications. It features the smallest transmitter housing available, delivering full performance in a compact footprint. This makes it a preferred choice for system integrators, skid builders, and equipment manufacturers.
Benefits
- Highest process safety – self-drainable measuring tube design
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Space-saving installation – no in/outlet run needed
- Space-saving transmitter – full functionality on the smallest footprint
- Time-saving local operation without additional software and hardware – integrated web server
- Integrated verification – Heartbeat Technology
Operating limits
- Max. process pressure: PN 40, Class 300, 20K, 400 bar (5800 psi)
- Medium temperature range: –50 to +205 °C (–58 to +401 °F)
- Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
- Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
Feed water / Medium
- Measuring range: 0 to 450 kg/h (0 to 16.5 lb/min)
Product water / Measured variables
- Mass flow
- Density
- Temperature
- Volume flow
- Corrected volume flow
- Reference density
- Concentration
Performance
- Max. measurement error (Mass flow, liquid): ±0.1 %
- Max. measurement error (Volume flow, liquid): ±0.1 %
- Max. measurement error (Mass flow, gas): ±0.5 %
- Max. measurement error (Density, liquid): ±0.0005 g/cm³
Mechanical / Hydraulic
- Nominal diameter range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
- Wetted materials (Measuring tube): 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
- Wetted materials (Connection): 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
- Sensor housing material: 1.4301 (304), corrosion resistant
Electrical
- Power supply: DC 20 to 30 V
- Outputs:
- 4–20 mA HART (active)
- Pulse/frequency/switch output (passive)
- Inputs: None
- Digital communication: HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Transmitter Features
- Housing material (Compact): AlSi10Mg, coated
- Housing material (Compact/ultra-compact): 1.4301 (304)
- Degree of protection (Standard): IP66/67, type 4X enclosure
- Degree of protection (Option): IP69
- Display/Operation:
- 4-line backlit display available (no local operation)
- Configuration via web browser and operating tools possible
Approvals and Certificates
- Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
- Product safety: CE, C-Tick, EAC marking
- Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR. Heartbeat Technology compliance with ISO 9001:2015 requirements.
- Pressure approvals and certificates: CRN
- Material certificates: 3.1 material
- Hygienic approvals and certificates: 3-A, EHEDG, cGMP
Disclaimer: This extracted summary may not include all figures, footnotes, or revisions. Contractual data must match the official OEM PDF revision used for the specific project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.