Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Proline Promass A 100

PDF datasheet mirror for Proline Promass A 100 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

  • Product line: Proline Promass A 100
  • Type: Coriolis flowmeter
  • Headline: The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.

Field of application

Promass A is designed for highly accurate measurement of small quantities of liquids and gases, suitable for high and low pressure applications. It features the smallest transmitter housing available, delivering full performance in a compact footprint. This makes it a preferred choice for system integrators, skid builders, and equipment manufacturers.

Benefits

  • Highest process safety – self-drainable measuring tube design
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in/outlet run needed
  • Space-saving transmitter – full functionality on the smallest footprint
  • Time-saving local operation without additional software and hardware – integrated web server
  • Integrated verification – Heartbeat Technology

Operating limits

  • Max. process pressure: PN 40, Class 300, 20K, 400 bar (5800 psi)
  • Medium temperature range: –50 to +205 °C (–58 to +401 °F)
  • Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
  • Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)

Feed water / Medium

  • Measuring range: 0 to 450 kg/h (0 to 16.5 lb/min)

Product water / Measured variables

  • Mass flow
  • Density
  • Temperature
  • Volume flow
  • Corrected volume flow
  • Reference density
  • Concentration

Performance

  • Max. measurement error (Mass flow, liquid): ±0.1 %
  • Max. measurement error (Volume flow, liquid): ±0.1 %
  • Max. measurement error (Mass flow, gas): ±0.5 %
  • Max. measurement error (Density, liquid): ±0.0005 g/cm³

Mechanical / Hydraulic

  • Nominal diameter range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
  • Wetted materials (Measuring tube): 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
  • Wetted materials (Connection): 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
  • Sensor housing material: 1.4301 (304), corrosion resistant

Electrical

  • Power supply: DC 20 to 30 V
  • Outputs:
    • 4–20 mA HART (active)
    • Pulse/frequency/switch output (passive)
  • Inputs: None
  • Digital communication: HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Transmitter Features

  • Housing material (Compact): AlSi10Mg, coated
  • Housing material (Compact/ultra-compact): 1.4301 (304)
  • Degree of protection (Standard): IP66/67, type 4X enclosure
  • Degree of protection (Option): IP69
  • Display/Operation:
    • 4-line backlit display available (no local operation)
    • Configuration via web browser and operating tools possible

Approvals and Certificates

  • Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
  • Product safety: CE, C-Tick, EAC marking
  • Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR. Heartbeat Technology compliance with ISO 9001:2015 requirements.
  • Pressure approvals and certificates: CRN
  • Material certificates: 3.1 material
  • Hygienic approvals and certificates: 3-A, EHEDG, cGMP