Summary

Product identification

  • Product line: Proline Promass A 500
  • Type: Coriolis flowmeter
  • Model: 8A5C

Field of application

The compact Promass A is ideal for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. The remote transmitter Promass A 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification. Suitable for applications with smallest flow quantities in all industries.

Sensor features

  • Space-saving installation – compact, lightweight sensor
  • Highest product quality – self-drainable measuring tube in all line sizes
  • Optimum process safety – resistant to corrosive ambient conditions and internal clogging

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology
  • Remote version with up to 4 I/Os
  • Backlit display with touch control and WLAN access
  • Standard cable between sensor and transmitter

Operating limits

  • Medium temperature range: -50 to 205 °C (-58 to 401 °F)
  • Max. process pressure: 430.9 bar (6250 psi)
  • Ambient temperature range: -40 to 60 °C (-40 to +140 °F)

Mechanical / hydraulic

  • Nominal diameter range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
  • Wetted materials: Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
  • Sensor housing material: Stainless steel, 1.4404 (316L)
  • Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
  • Degree of protection:
    • Sensor remote version (standard): IP66/67, Type 4X enclosure
    • Sensor remote version (option): IP69
    • Transmitter remote version: IP66/67, Type 4X enclosure

Measured variables

  • Mass flow
  • Density
  • Temperature
  • Volume flow
  • Corrected volume flow
  • Reference density

Performance

  • Measuring range: 0 to 450 kg/h (0 to 16.54 lb/min)
  • Max. measurement error:
    • Mass flow (liquid): ±0.1 %
    • Volume flow (liquid): ±0.1 %
    • Mass flow (gas): ±0.35 %
    • Density (liquid): ±0.0005 g/cm³

Electrical

  • Outputs (4 outputs):
    • 4-20 mA HART (active/passive)
    • 4-20 mA WirelessHART
    • 4-20 mA (active/passive)
    • Pulse/frequency/switch output (active/passive)
    • Double pulse output (active/passive)
    • Relay output
  • Inputs:
    • Status input
    • 4-20 mA input
  • Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
  • Power supply:
    • DC 24 V
    • AC 100 to 230 V
    • AC 100 to 230 V / DC 24 V (non-hazardous area)

Approvals and certifications

  • Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, NEPSI
  • Product safety: CE, C-TICK
  • Functional safety: Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
  • Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025); Heartbeat Technology complies with ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • Pressure approvals and certificates: PED, CRN
  • Material certificates: 3.1 material
  • Hygienic approvals and certificates: 3-A, cGMP