Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Proline Promass E 200

PDF datasheet mirror for Proline Promass E 200 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

  • Product: Proline Promass E 200 / 8E2C
  • Type: Coriolis flowmeter

Field of application

Reliable solution for accurately measuring liquids and gases in standard applications, particularly in the chemical industry. Suitable for hazardous areas with intrinsically safe design (Ex ia). Features Heartbeat Technology for process safety.

Benefits

  • Cost-effective alternative to conventional volumetric flowmeters.
  • Multivariable measurement (flow, density, temperature) reduces the number of process measuring points.
  • Space-saving installation with no in-/outlet run requirements.
  • Convenient wiring via a separate connection compartment.
  • Safe operation with an external touch-controlled display.
  • Integrated verification with Heartbeat Technology.

Operating limits

  • Medium temperature range: –40 to +150 °C (–40 to +302 °F)
  • Ambient temperature range: –40 to +60 °C (–40 to +140 °F)
  • Max. process pressure: PN 100, Class 600, 63K

Feed water

  • Nominal diameter range: DN 8 to 50 (⅜ to 2")

Product water

  • Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow, reference density

Performance

  • Max. measurement error (Mass flow, liquid): ±0.25 % (standard)
  • Max. measurement error (Volume flow, liquid): ±0.25 %
  • Max. measurement error (Mass flow, gas): ±0.50 %
  • Max. measurement error (Density, liquid): ±0.0005 g/cm³
  • Measuring range: 0 to 70,000 kg/h (0 to 2570 lb/min)

Electrical

  • Power supply:
    • DC 18 to 35 V (4–20 mA HART with/without pulse/frequency/switch)
    • DC 18 to 30 V (20 mA HART, 4–20 mA)
    • DC 9 to 32 V (PROFIBUS PA)
  • Outputs:
    • 4–20 mA HART (passive)
    • 4–20 mA (passive)
    • Pulse/frequency/switch output (passive)
  • Digital communication: HART, PROFIBUS PA, FOUNDATION Fieldbus

Mechanical / hydraulic

  • Wetted materials:
    • Measuring tube: 1.4539 (904L)
    • Connection: 1.4404 (316/316L)
  • Sensor housing material: 1.4301 (304), corrosion resistant
  • Transmitter housing material: AlSi10Mg, coated
  • Degree of protection: IP66/67, type 4X enclosure

Approvals and certificates

  • Hazardous area: ATEX, IECEx, cCSAus, JPN, UK Ex
  • Product safety: CE, C-Tick, EAC marking
  • Functional safety: IEC 61508, IEC 61511
  • Metrological: ISO/IEC 17025 calibration
  • Pressure: PED, CRN
  • Material: 3.1 material certificates
  • Hygienic: 3-A, EHEDG, cGMP

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.