Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Proline Promass F 200

PDF datasheet mirror for Proline Promass F 200 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

  • Product name: Proline Promass F 200
  • Product type: Coriolis flowmeter
  • Headline: Robust flowmeter with genuine loop-powered technology. Highest measurement performance for liquids and gases in a wide range of applications.

Operating limits

  • Max. process pressure: PN 100, Class 600, 63K
  • Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F)
  • Medium temperature range (Option): –50 to +205 °C (–58 to +401 °F)
  • Ambient temperature range: –40 to +60 °C (–40 to +140 °F)

Feed water

N/A

Product water

N/A

Electrical

  • Outputs:
    • 4–20 mA HART (passive)
    • 4–20 mA (passive)
    • Pulse/frequency/switch output (passive)
  • Inputs: None
  • Digital communication: HART, PROFIBUS PA, FOUNDATION Fieldbus
  • Power supply:
    • DC 18 to 35 V (4–20 mA HART with/without pulse/frequency/switch)
    • DC 18 to 30 V (20 mA HART, 4–20 mA)
    • DC 9 to 32 V (PROFIBUS PA)

Mechanical / hydraulic

  • Nominal diameter range: DN 8 to 80 (⅜ to 3")
  • Wetted materials (Measuring tube): 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022)
  • Wetted materials (Connection): 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
  • Sensor housing material: 1.4301/1.4307 (304L), corrosion resistant
  • Transmitter housing material: AlSi10Mg, coated, 1.4404 (316L)
  • Degree of protection: IP66/67, type 4X enclosure

Performance

  • Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow, reference density
  • Max. measurement error (Mass flow - liquid): ±0.1 %
  • Max. measurement error (Volume flow - liquid): ±0.1 %
  • Max. measurement error (Mass flow - gas): ±0.25 %
  • Max. measurement error (Density - liquid): ±0.0005 g/cm³
  • Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)

Features and Approvals

  • Display/Operation: 4-line backlit display with touch control (operation from outside)
  • Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
  • Product safety: CE, C-TICK, EAC marking
  • Functional safety: According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
  • Metrological approvals and certificates: Calibration accredited (ISO/IEC 17025), Heartbeat Technology (ISO 9001:2015)
  • Pressure approvals and certificates: PED, CRN, AD 2000
  • Material certificates: 3.1 material, NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
  • Hygienic approvals and certificates: 3-A, EHEDG, cGMP

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.