Summary

Product identification

  • Product: Proline Promass F 300
  • Product Type: Coriolis flowmeter
  • Headline: Flowmeter with premium accuracy, robustness and a compact, easily accessible transmitter.

Operating limits

  • Max. process pressure: PN 100, Class 600, 63K
  • Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F)
  • Medium temperature range (Option): –50 to +240 °C (–58 to +464 °F)
  • Medium temperature range (High temp option): –50 to +350 °C (–58 to +662 °F)
  • Medium temperature range (Cryogenic option): –196 to +150 °C (–320 to +302 °F)
  • Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
  • Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)

Mechanical / hydraulic

  • Measuring principle: Coriolis
  • Nominal diameter range: DN 8 to 250 (⅜ to 10")
  • Wetted materials - Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
  • Wetted materials - Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
  • Sensor housing material (Standard): 1.4301 (304)
  • Sensor housing material (Option): 1.4404 (316/316L)
  • Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design
  • Degree of protection (Compact version): IP66/67, type 4X enclosure
  • Degree of protection (External WLAN antenna): IP67
  • Degree of protection (General): IP69

Measured variables

  • Mass flow
  • Density
  • Temperature
  • Volume flow
  • Corrected volume flow
  • Reference density
  • Concentration

Performance

  • Max. measurement error - Mass flow (liquid) (standard): ±0.10 %
  • Max. measurement error - Mass flow (liquid) (option): ±0.05 %
  • Max. measurement error - Volume flow (liquid): ±0.10 %
  • Max. measurement error - Mass flow (gas): ±0.25 %
  • Max. measurement error - Density (liquid): ±0.0005 g/cm³
  • Measuring range: 0 to 2,200,000 kg/h (0 to 80,840 lb/min)

Electrical

  • Outputs:
    • 4-20 mA HART (active/passive)
    • 4-20 mA WirelessHART
    • 4-20 mA (active/passive)
    • Pulse/frequency/switch output (active/passive)
    • Double pulse output (active/passive)
    • Relay output
  • Inputs:
    • Status input
    • 4-20 mA input
  • Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
  • Power supply:
    • DC 24 V
    • AC 100 to 230 V
    • AC 100 to 230 V / DC 24 V (non-hazardous area)

Approvals and Certifications

  • Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
  • Product safety: CE, C-tick, EAC marking
  • Functional safety: According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
  • Metrological approvals: MI-005, NTEP, MC, MI-002, PTB
  • Marine approvals: LR, DNV, ABS, BV, CCS
  • Pressure approvals: PED, CRN, AD 2000
  • Material certificates: 3.1 material, NACE MR0175/MR0103, PMI, welding test acc. to EN ISO, ASME, NORSOK
  • Hygienic approvals: 3-A, EHEDG, cGMP

Display / Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Features

  • Highest process safety – immune to fluctuating and harsh environments.
  • Fewer process measuring points – multivariable measurement (flow, density, temperature).
  • Space-saving installation – no in-/outlet run needs.
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses.
  • Reduced complexity and variety – freely configurable I/O functionality.
  • Integrated verification – Heartbeat Technology.
  • Compact dual-compartment housing with up to 3 I/Os.
  • Backlit display with touch control and WLAN access.