Summary

Product identification

  • Product: Proline Promass I 500 / 8I5B
  • Type: Coriolis flowmeter
  • Headline: Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os.
  • Field of application: Measurement of liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

Operating limits

  • Max. process pressure: PN 100, Class 600, 63K
  • Medium temperature range: –50 to +150 °C (–58 to +302 °F)
  • Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
  • Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)

Feed water

  • Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min)

Product water

  • Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

Performance

  • Max. measurement error (Mass flow, liquid): ±0.10 %
  • Max. measurement error (Volume flow, liquid): ±0.10 %
  • Max. measurement error (Mass flow, gas): ±0.50 %
  • Max. measurement error (Density, liquid): ±0.0005 g/cm³

Mechanical / hydraulic

  • Nominal diameter range: DN 8 to 80 (⅜ to 3")
  • Wetted materials:
    • Measuring tube: Titanium grade 9
    • Connection: Titanium grade 2
  • Sensor housing material: 1.4301 (304), corrosion resistant
  • Sensor connection housing (standard): AlSi10Mg, coated
  • Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
  • Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
  • Degree of protection (Sensor remote version, standard): IP66/67, type 4X enclosure
  • Degree of protection (Sensor remote version, option): IP69
  • Degree of protection (Transmitter remote version): IP66/67, Type 4X enclosure

Electrical

  • Outputs: 4 outputs:
    • 4-20 mA HART (active/passive)
    • 4-20 mA WirelessHART
    • 4-20 mA (active/passive)
    • Pulse/frequency/switch output (active/passive)
    • Double pulse output (active/passive)
    • Relay output
  • Inputs:
    • Status input
    • 4-20 mA input
  • Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
  • Power supply:
    • DC 24 V
    • AC 100 to 230 V
    • AC 100 to 230 V / DC 24 V (non-hazardous area)

Approvals and Certificates

  • Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
  • Product safety: CE, C-tick, EAC marking
  • Functional safety: Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
  • Metrological approvals: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025); Heartbeat Technology complies with requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • Pressure approvals: PED, CRN
  • Material certificates: 3.1 material
  • Hygienic approvals: 3-A, EHEDG, cGMP

Features

  • Energy-saving – full-bore design enables minimal pressure loss.
  • Fewer process measuring points – multivariable measurement (flow, density, temperature).
  • Space-saving installation – no in-/outlet run needs.
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet.
  • Reduced complexity and variety – freely configurable I/O functionality.
  • Integrated verification – Heartbeat Technology.
  • Straight, easy-to-clean single-tube system.
  • TMB technology.
  • Remote transmitter version with up to 4 I/Os.
  • Backlit display with touch control and WLAN access.
  • Standard cable between sensor and transmitter.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.