Datasheet summary
Proline Promass O 100
PDF datasheet mirror for Proline Promass O 100 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product: Proline Promass O 100
- Type: Coriolis flowmeter
- Headline: Robust high-pressure flowmeter with an ultra-compact transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions.
Field of application
Promass O is designed for premium accuracy of liquids and gases at the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. Promass O 100 delivers full performance on the smallest footprint with its ultra-compact transmitter and thus enables seamless system integration. Heartbeat Technology enables process safety at all times.
Features and specifications
Sensor features
- Maximum safety – highest resistance to stress corrosion cracking
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Space-saving installation – no in-/outlet run needs
- Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750)
Transmitter features
- Space-saving transmitter – full functionality on the smallest footprint
- Time-saving local operation without additional software and hardware – integrated web server
- Robust, ultra-compact transmitter housing
- Highest degree of protection: IP69
- Local display available
Operating limits
Max. process pressure
- PN 250, Class 1500
Medium temperature range
- –40 to +205 °C (–40 to +401 °F)
Ambient temperature range
- Standard: –40 to +60 °C (–40 to +140 °F)
- Option: –50 to +60 °C (–58 to +140 °F)
Feed water
Nominal diameter range
- DN 80 to 150 (3 to 6")
Wetted materials
- Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
- Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)
- Measuring tube (alternative): 1.4539 (904L)
Product water
Measured variables
- Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Max. measurement error
- Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
- Volume flow (liquid): ±0.1 %
- Mass flow (gas): ±0.35 %
- Density (liquid): ±0.0005 g/cm³
Measuring range
- 0 to 800 000 kg/h (0 to 29 400 lb/min)
Electrical
Outputs
- 4–20 mA HART (active)
- Pulse/frequency/switch output (passive)
Inputs
- None
Digital communication
- HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply
- DC 20 to 30 V
Mechanical / hydraulic
Sensor housing material
- 1.4404 (316L), highest corrosion resistance
Transmitter housing material
- Compact: AlSi10Mg, coated
- Compact/ultra-compact: 1.4404 (316L)
Degree of protection
- Standard: IP66/67, type 4X enclosure
- Option: IP69
Display/Operation
- 4-line backlit display available (no local operation)
- Configuration via web browser and operating tools possible
Approvals and certificates
Hazardous area approvals
- ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Product safety
- CE, C-Tick, EAC marking
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates
- PED, CRN, AD 2000
Material certificates
- 3.1 material
- NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)