Datasheet summary
Proline Promass S 500
PDF datasheet mirror for Proline Promass S 500 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product name: Proline Promass S 500 / 8S5B
- Type: Coriolis flowmeter
- Headline: Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
- Application: Dedicated to applications in the food and beverage industry requiring optimal cleanability under hygienic conditions.
Features and specifications
- Measuring principle: Coriolis
- Sensor features:
- Easily cleanable and fully self-drainable tube design for increased process safety.
- Multivariable measurement (flow, density, temperature) reduces the number of process measuring points.
- Space-saving installation with no in-/outlet run requirement.
- Large range of hygienic process connections.
- 3-A and EHEDG conform.
- Fast recovery from CIP/SIP.
- Transmitter features:
- Numerous, freely combinable I/Os and fieldbuses for full access to process and diagnostic information.
- Freely configurable I/O functionality reduces complexity and variety.
- Integrated verification with Heartbeat Technology.
- Remote version with up to 4 I/Os.
- Hygienic sensor connection housing with IP69.
- Backlit display with touch control and WLAN access.
- Standard cable between sensor and transmitter.
Operating limits
- Nominal diameter range: DN 8 to 50 (⅜ to 2")
- Max. measurement error:
- Mass flow (liquid): ±0.10 %
- Volume flow (liquid): ±0.10 %
- Density (liquid): ±0.0005 g/cm³
- Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
- Max. process pressure: PN 40, Class 150, 20K
- Medium temperature range: –50 to +150 °C (–58 to +302 °F)
- Ambient temperature range:
- Standard: –40 to +60 °C (–40 to +140 °F)
- Option: –50 to +60 °C (–58 to +140 °F)
Feed water
- Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Product water
- Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Electrical
- Outputs: 4 outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA WirelessHART
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Double pulse output (active/passive)
- Relay output
- Inputs:
- Status input
- 4-20 mA input
- Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
- Power supply:
- DC 24 V
- AC 100 to 230 V
- AC 100 to 230 V / DC 24 V (non-hazardous area)
Mechanical / hydraulic
- Wetted materials:
- Measuring tube: 1.4435 (316L)
- Connection: 1.4435 (316L); 1.4404 (316/316L)
- Sensor housing material: 1.4301 (304), corrosion resistant
- Sensor connection housing (standard): AlSi10Mg, coated
- Sensor connection housing (option): 1.4301 (304); 1.4404 (316L)
- Transmitter housing material: AlSi10Mg, coated; Polycarbonat
- Degree of protection:
- Sensor remote version (standard): IP66/67, type 4X enclosure
- Sensor remote version (option): IP69
- Transmitter remote version: IP66/67, Type 4X enclosure
- Display/Operation: 4-line backlit display with touch control (operation from outside)
Approvals and certifications
- Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
- Product safety: CE, C-tick, EAC marking
- Functional safety: According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
- Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025); Heartbeat Technology complies with ISO 9001:2015 requirements for measurement traceability.
- Pressure approvals and certificates: PED, CRN
- Material certificates: 3.1 material
- Hygienic approvals and certificates: 3-A, EHEDG, cGMP
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.