
Datasheet summary
Proline Promass X 500
PDF datasheet mirror for Proline Promass X 500 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product: Proline Promass X 500 / 8X5B
- Type: Coriolis flowmeter
- Headline: Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os.
- Application: For highest flow rates and outstanding performance in on/offshore oil and gas applications.
Operating limits
- Max. process pressure: PN 100, Class 600
- Medium temperature range: –50 to +180 °C (–58 to +356 °F)
- Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
- Ambient temperature range (Option): –60 to +60 °C (–76 to +140 °F)
Feed water
- Measuring range: 0 to 4100 t/h (0 to 4520 tn. sh./h)
Product water
- Max. measurement error (Mass flow, liquid): ±0.10 % (standard), 0.05 % (option)
- Max. measurement error (Volume flow, liquid): ±0.10 %
- Max. measurement error (Mass flow, gas): ±0.35 %
- Max. measurement error (Density, liquid): ±0.0005 g/cm³
Electrical
- Outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA WirelessHART
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Double pulse output (active/passive)
- Relay output
- Inputs:
- Status input
- 4-20 mA input
- Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
- Power supply:
- DC 24 V
- AC 100 to 230 V
- AC 100 to 230 V / DC 24 V (non-hazardous area)
Mechanical / hydraulic
- Nominal diameter range: DN 300 to 400 (12 to 16")
- Wetted materials (Measuring tube & Connection): 1.4404 (316/316L)
- Sensor housing material: 1.4404 (316L)
- Sensor connection housing (standard): 1.4409 (CF3M)
- Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M); Polycarbonat
- Degree of protection (Sensor remote version, standard): IP66/67, type 4X enclosure
- Degree of protection (Sensor remote version, option): IP69
- Degree of protection (Transmitter remote version): IP66/67, Type 4X enclosure
- Display/Operation: 4-line backlit display with touch control and WLAN access.
Other specifications
- Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
- Heartbeat Technology: Integrated verification.
- Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
- Product safety: CE, C-tick, EAC marking
- Functional safety: According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
- Metrological approvals: MI-005 (Liquids other than water (Hydrocarbons), LPG, cryogenic), MI-002, PTB. Calibration accredited to ISO/IEC 17025.
- Marine approvals: LR, DNV, ABS, BV, CCS
- Pressure approvals: PED, CRN
- Material certificates: 3.1 material, NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.