Proline Promass X 500

PDF datasheet mirror for Proline Promass X 500 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

  • Product: Proline Promass X 500 / 8X5B
  • Type: Coriolis flowmeter
  • Headline: Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os.
  • Application: For highest flow rates and outstanding performance in on/offshore oil and gas applications.

Operating limits

  • Max. process pressure: PN 100, Class 600
  • Medium temperature range: –50 to +180 °C (–58 to +356 °F)
  • Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
  • Ambient temperature range (Option): –60 to +60 °C (–76 to +140 °F)

Feed water

  • Measuring range: 0 to 4100 t/h (0 to 4520 tn. sh./h)

Product water

  • Max. measurement error (Mass flow, liquid): ±0.10 % (standard), 0.05 % (option)
  • Max. measurement error (Volume flow, liquid): ±0.10 %
  • Max. measurement error (Mass flow, gas): ±0.35 %
  • Max. measurement error (Density, liquid): ±0.0005 g/cm³

Electrical

  • Outputs:
    • 4-20 mA HART (active/passive)
    • 4-20 mA WirelessHART
    • 4-20 mA (active/passive)
    • Pulse/frequency/switch output (active/passive)
    • Double pulse output (active/passive)
    • Relay output
  • Inputs:
    • Status input
    • 4-20 mA input
  • Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
  • Power supply:
    • DC 24 V
    • AC 100 to 230 V
    • AC 100 to 230 V / DC 24 V (non-hazardous area)

Mechanical / hydraulic

  • Nominal diameter range: DN 300 to 400 (12 to 16")
  • Wetted materials (Measuring tube & Connection): 1.4404 (316/316L)
  • Sensor housing material: 1.4404 (316L)
  • Sensor connection housing (standard): 1.4409 (CF3M)
  • Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M); Polycarbonat
  • Degree of protection (Sensor remote version, standard): IP66/67, type 4X enclosure
  • Degree of protection (Sensor remote version, option): IP69
  • Degree of protection (Transmitter remote version): IP66/67, Type 4X enclosure
  • Display/Operation: 4-line backlit display with touch control and WLAN access.

Other specifications

  • Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
  • Heartbeat Technology: Integrated verification.
  • Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
  • Product safety: CE, C-tick, EAC marking
  • Functional safety: According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
  • Metrological approvals: MI-005 (Liquids other than water (Hydrocarbons), LPG, cryogenic), MI-002, PTB. Calibration accredited to ISO/IEC 17025.
  • Marine approvals: LR, DNV, ABS, BV, CCS
  • Pressure approvals: PED, CRN
  • Material certificates: 3.1 material, NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK