Datasheet summary
Proline Prosonic Flow I 400
PDF datasheet mirror for Proline Prosonic Flow I 400 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product line: Proline Prosonic Flow I 400 ultrasonic flowmeter
- Type: Insertion flowmeter with Heartbeat Technology and web server for the water and wastewater industry.
- Model: Proline Prosonic Flow I 400 / 9I4B
Field of application
Insertion sensor technology combined with Proline 400 transmitters. Suitable for large pipelines such as water distribution lines and projects where a fixed device installation is necessary. Bidirectional flow measurement of water and wastewater. Supports two parallel measurement paths.
Benefits
- Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 4000/160").
- Long-term stable signal – maintenance-free direct installation of the sensor into the medium.
- Process transparency – diagnostic capability.
- Safe operation – no need to open the device due to display with touch control and background lighting.
- Full remote access – web server.
- Integrated diagnostics, verification and monitoring – Heartbeat Technology.
Operating limits
- Medium temperature range: –40 to +80 °C (–40 to +176 °F)
- Ambient temperature range: -20 to 60°C (-4 to 140°F)
- Max. process pressure: N/A
Feed water
- Measured variables: Volume flow, Flow velocity, Sound velocity
- Measuring principle: Ultrasonic flow
- Nominal diameter range: DN200 to 4000 (8 to 160")
- Measuring range: 0 to 15 m/s (0 to 50 ft/s)
- Max. measurement error (Volume flow): ±2% o.r. above DN200
Product water
(Not specified in the extract)
Electrical
- Power supply: AC 100 to 240 V / AC/DC 24 V
- Outputs: 3 outputs:
- 4‐20 mA/4‐20 mA HART (active)
- Pulse/frequency/switch output (passive)
- Pulse/frequency/switch output (passive)
- Inputs: Status input
- Digital communication: HART
Mechanical / hydraulic
- Wetted materials:
- Insertion system: Sensor holder 1.4301 (304), 1.4404 (316L); Sensor housing 1.4301 (304), 1.4404 (316L)
- Transmitter housing material:
- Wall-mounted housing: Polycarbonat; AlSi10Mg, coated
- Degree of protection:
- Transmitter: IP66/67, Type 4X enclosure
- Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure (optional)
- Display/Operation: 4‐line backlit display with touch control (operation from outside). Configuration via local display, web browser and operating tools possible.
- Integrated data logger: Measured values monitoring.
Approvals
- Product safety: CE, C-tick marking, EAC-marking
- Metrological approvals and certificates: Flowmeter verification performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a.
- Other approvals: cCSAus, Marine approvals and certificates (details not specified)
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)