Datasheet summary
Proline Prowirl D 200
PDF datasheet mirror for Proline Prowirl D 200 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product Identification
- Product Name: Proline Prowirl D 200
- Type: Vortex flowmeter
- Description: Cost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates.
Features and Specifications
General
- Measuring principle: Vortex
- Nominal diameter range: DN 15 to 150 (½ to 6")
- Face-to-face length: 65 mm (2.56 in)
- Installation: Wafer type, designed to be installed directly between flanges.
- Sensor Alignment: Easy alignment with included centering rings.
Sensor Features
- Robustness: High availability, resistance to vibrations, temperature shocks, and water hammer.
- Stability: Long-term stability due to drift-free capacitive sensor.
Transmitter Features
- Wiring: Convenient device wiring with separate connection compartment.
- Operation: Safe operation without opening the device due to display with touch control and background lighting.
- Verification: Integrated Heartbeat Technology.
- Display: 4-line backlit display with touch control. Display module with data transfer function.
- Housing: Robust dual-compartment housing.
- Approvals: Worldwide approvals (SIL, Haz. area).
Measured Variables
- Volume flow
- Mass flow
- Corrected volume flow
- Energy flow
- Heat flow difference
- Temperature
Performance
- Max. measurement error:
- Volume flow (liquid): ±0.75 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (liquid): ±0.85%
- Mass flow (steam, gas): ±1.7 %
- Measuring range:
- Liquid: 0.25 to 625 m³/h (0.15 to 365 ft³/min) (e.g., water at 1 bar a, 20 °C)
- Steam, gas: 2.1 to 8335 m³/h (1.2 to 4906 ft³/min) (e.g., steam at 180 °C, 10 bar a; air at 25 °C, 4.4 bar a)
Operating Limits
Process Conditions
- Max. process pressure: PN 40, Class 300, 20K
- Medium temperature range:
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
- High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient Temperature Range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Materials
- Wetted materials:
- Measuring tube: 1.4408 (CF3M)
- DSC sensor: 1.4435 (316/316L)
- Sensor housing material: AlSi10Mg, coated; 1.4408 (CF3M)
- Transmitter housing material: AlSi10Mg, coated; 1.4404 (316L)
Electrical
Outputs
- 4–20 mA HART (passive)
- 4–20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- Current input 4–20 mA (passive)
Digital Communication
- HART
- PROFIBUS PA
- FOUNDATION Fieldbus
Power Supply
- DC 12 to 35 V (for 4–20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (for 4–20 mA HART, 4–20 mA)
- DC 12 to 35 V (for 4–20 mA HART, pulse/frequency/switch output, 4–20 mA input)
- DC 9 to 32 V (for PROFIBUS PA, pulse/frequency/switch output)
Degree of Protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version: IP66/67, type 4X enclosure
- Transmitter remote version: IP66/67, type 4X enclosure
Approvals and Certifications
- Hazardous area approvals: ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
- Product safety: CE, C-TICK, EAC
- Functional safety: IEC 61508, IEC 61511
- Metrological approvals: Calibration traceable to ISO/IEC 17025. Heartbeat Technology complies with ISO 9001:2015 requirements for measurement traceability.
- Marine approvals: ABS, LR, BV, DNV
- Pressure approvals: PED, CRN
- Material certificates: 3.1 material, NACE MR0175/MR0103, PMI (on request)
Disclaimer
This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.