Datasheet summary
Proline Prowirl R 200
PDF datasheet mirror for Proline Prowirl R 200 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
Product: Proline Prowirl R 200 vortex flowmeter
Headline: Flowmeter with best-in-class accuracy despite pipe reduction.
Field of application
Designed for low flows and energy management. Offers cost-effective and seamless integration with genuine loop-powered technology. Suitable for hazardous areas with highest operational safety. Heartbeat Technology enables process safety.
Features and specifications
- Measuring principle: Vortex
- Sensor features: Robust drift-free capacitive sensor, long-term stability. Integrated diameter reduction by 1 or 2 line sizes.
- Transmitter features: Flexible positioning of pressure cell.
- Nominal diameter range: DN 25 to 250 (1 to 10")
- Wetted materials:
- Measuring tube: 1.4408 (CF3M)
- DSC sensor: 1.4404/F316/F316L
- Process connection: 1.4404/F316/F316L
Measured variables
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature.
Performance
- Max. measurement error:
- Volume flow (liquid): ±0.75 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
- Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
- Mass flow (liquid): ±0.85%
- Measuring range:
- Liquid: 0.2 to 540 m³/h (0.15 to 320 ft³/min) (e.g., water with 1 bar a, 20 °C)
- Steam, gas: 1.5 to 7260 m³/h (0.9 to 4270 ft³/min) (e.g., steam with 180 °C, 10 bar a; air with 25 °C, 4.4 bar a)
- Accuracy: Same accuracy down to Re 10,000.
Operating limits
- Max. process pressure: PN 40, Class 300, 20K
- Medium temperature range:
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
- High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
- Ambient temperature range:
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Mechanical / hydraulic
- Sensor housing material: AlSi10Mg, coated; 1.4408 (CF3M)
- Transmitter housing material: AlSi10Mg, coated; 1.4404 (316L)
- Degree of protection: IP66/67, type 4X enclosure (all versions)
Electrical
- Display/Operation: 4-line backlit display with touch control, operation from outside. Local and remote display options.
- Outputs: 4–20 mA HART (passive), 4–20 mA (passive), Pulse/frequency/switch output (passive).
- Inputs: 4–20 mA (passive).
- Digital communication: HART, PROFIBUS PA, FOUNDATION Fieldbus.
- Power supply:
- DC 12 to 35 V (4–20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (4–20 mA HART, 4–20 mA)
- DC 12 to 35 V (4–20 mA HART, pulse/frequency/switch output, 4–20 mA input)
- DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Certifications and approvals
- Hazardous area approvals: ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
- Product safety: CE, C-tick, EAC
- Functional safety: According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511.
- Metrological: Accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology traceable to ISO 9001:2015.
- Marine: ABS, LR, BV, DNV
- Pressure: PED, CRN, AD 2000
- Material: 3.1 material, NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request).
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.